SearcharxivSearch

arXiv subjects

J. Edelen

Publications and source records attributed to J. Edelen.

5 recordsLinked to original sources

A Compact Low-level RF Control System for Advanced Concept Compact Electron Linear Accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analogue up and down conversion. Compared with the conventional heterodyne based architecture used for LLRF system of linear accelerator (LINAC), the elimination of analogue mixers can significantly reduce the size and weight of the system, especially with LINAC requires a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1 degree, on the flat top of a 2 microseconds RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. This paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

physics.acc-ph

LLRF System Considerations for a Compact, Commercial C-band Accelerator using the AMD Xilinx RF-SoC

This work describes the LLRF and control system in use for a novel accelerator structure developed for a compact design operating in C-band developed by SLAC, with collaboration from RadiaBeam and RadiaSoft. This design is a pulsed RF/pulsed beam system that only provides minimal monitoring for control of each two-cavity pair. Available signals include only a forward and reflected signal for each pair; such a design requires careful consideration of calibration and power-on routines, as well an understanding of how to correct for disturbances caused by the entire RF signal chain, including a new SSA, klystron, and distribution system. An AMD Xilinx RF-SoC with a separate supervisory computer is the LLRF system core, with on-board pulse-to-pulse feedback corrections. This work presents the current status of the project, as well as obstacles and manufacturing plans from the viewpoint of developing for larger-volume manufacturing. This material is based upon work supported by the Defense Advanced Research Projects Agency under Contract Numbers 140D0423C0006 and 140D0423C0007. The views, opinions, and/or findings expressed are those of the author(s) and should not be interpreted as representing the official views or policies of the Department of Defense or the U.S. Government.

physics.acc-ph

Impact of Electron Transport Models on Capillary Discharge Plasmas

Magnetohydrodynamics (MHD) can be used to model capillary discharge waveguides in laser-wakefield accelerators. However, the predictive capability of MHD can suffer due to poor microscopic closure models. Here, we study the impact of electron heating and thermal conduction on capillary waveguide performance as part of an effort to understand and quantify uncertainties in modeling and designing next-generation plasma accelerators. To do so, we perform two-dimensional high-resolution MHD simulations using an argon-filled capillary discharge waveguide with three different electron transport coefficients models. The models tested include (i) Davies et al. (ii) Spitzer, and (iii) Epperlein-Haines (EH). We found that the EH model overestimates the electron temperature inside the channel by over $20\%$ while predicting a lower azimuthal magnetic field. Moreover, the Spitzer model, often used in MHD simulations for plasma-based accelerators, predicts a significantly higher electron temperature than the other models suggest.

physics.plasm-ph

Commissioning And First Results From The Fermilab Cryomodule Test Stand

A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

physics.acc-ph

Installation Progress At The PIP-II Injector Test At Fermilab

A CW-compatible, pulsed H- superconducting linac "PIP-II" is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test accelerator (The PIP-II Injector Test, formerly known as "PXIE") is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV Radio Frequency Quadrupole (RFQ) capable of operation in Continuous Wave (CW) mode, and a 10 m-long Medium Energy Beam Transport (MEBT). The paper will report on the installation of the RFQ and the first sections of the MEBT and related mechanical design considerations.

physics.acc-ph