SearcharxivSearch

arXiv subjects

J. Hoffman

Publications and source records attributed to J. Hoffman.

At least 19 recordsLinked to original sources

Trigger system for the Payload for Ultrahigh Energy Observations (PUEO) balloon-borne neutrino detector

The Payload for Ultrahigh Energy Observations (PUEO) is a NASA balloon-borne instrument for the detection of ultra-high energy (UHE) neutrinos with energies above $10^{17.5}~\textrm{eV}$ via either the Askaryan effect or geomagnetic emissions from an upward-going air shower. The main instrument trigger system for PUEO is a fully digital supersample rate beamformer based on 24 Xilinx Radio Frequency System-on-a-Chip (RFSoC) digitizers sampling 192 channels operating at $3~\textrm{GSa/s}$ and a system clock frequency of $375~\textrm{MHz}$. The trigger implements frequency band conditioning, dynamic radio-frequency interference (RFI) rejection, and matched filtering, with significant emphasis on optimization to reduce both the power and resource usage while maintaining sensitivity. The system implements 48 total synthetic antenna beams with up to 8 antennas each, covering a $\sim25^\circ$ range in zenith and $\sim60^\circ$ range in azimuth. Preflight testing demonstrated a trigger performance of a minimum signal-to-noise ratio (SNR) of $\sim1.5$ using simulated signals while consuming between $5-7~\textrm{W}$ in the trigger logic.

astro-ph.IM

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10-1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov (KSVZ) sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

hep-ex

Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $\mu$eV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

hep-ex

Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

astro-ph.CO

Axion Dark Matter eXperiment around 3.3 {\mu}eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $\mu$eV, assuming a standard halo model with a local energy density of 0.45 GeV/cm$^3$ made up 100% of axions.

hep-ex

Axion Dark Matter eXperiment: Run 1A Analysis Details

The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.

hep-ex

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 {\mu}eV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

astro-ph.CO

Search for a dark-matter induced Cosmic Axion Background with ADMX

We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analysis strategy, which searches for a C$a$B induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a C$a$B originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a C$a$B or even high-frequency gravitational waves.

hep-ex

Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.

hep-ph

Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range

We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.

hep-ex

Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier

We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

hep-ex

Splitting of ISGMR strength in the light-mass nucleus $^{24}$Mg due to ground-state deformation

The isoscalar giant monopole resonance (ISGMR) strength distribution in $^{24}$Mg has been determined from background-free inelastic scattering of 386-MeV $α$ particles at extreme forward angles, including 0$^{\circ}$. The ISGMR strength distribution has been observed for the first time to have a two-peak structure in a light-mass nucleus. This splitting of ISGMR strength is explained well by microscopic theory in terms of the prolate deformation of the ground state of $^{24}$Mg.

nucl-ex

Spectral weight redistribution in (LaNiO3)n/(LaMnO3)2 superlattices from optical spectroscopy

We have studied the optical properties of four (LaNiO$_3$)$_n$/(LaMnO$_3$)$_2$ superlattices (SL) ($n$=2, 3, 4, 5) on SrTiO$_3$ substrates. We have measured the reflectivity at temperatures from 20 K to 400 K, and extracted the optical conductivity through a fitting procedure based on a Kramers-Kronig consistent Lorentz-Drude model. With increasing LaNiO$_3$ thickness, the SLs undergo an insulator-to-metal transition (IMT) that is accompanied by the transfer of spectral weight from high to low frequency. The presence of a broad mid-infrared band, however, shows that the optical conductivity of the (LaNiO$_3$)$_n$/(LaMnO$_3$)$_2$ SLs is not a linear combination of the LaMnO$_3$ and LaNiO$_3$ conductivities. Our observations suggest that interfacial charge transfer leads to an IMT due to a change in valence at the Mn and Ni sites.

cond-mat.str-el

Oscillatory Non-collinear Magnetism Induced by Interfacial Charge Transfer in Metallic Oxide Superlattices

Interfaces between correlated complex oxides are promising avenues to realize new forms of magnetism that arise as a result of charge transfer, proximity effects and locally broken symmetries. We report upon the discovery of a non-collinear magnetic structure in superlattices of the ferromagnetic metallic oxide La2/3Sr1/3MnO3 (LSMO) and the correlated metal LaNiO3 (LNO). The exchange interaction between LSMO layers is mediated by the intervening LNO, such that the angle between the magnetization of neighboring LSMO layers varies in an oscillatory manner with the thickness of the LNO layer. The magnetic field, temperature, and spacer thickness dependence of the non-collinear structure are inconsistent with the bilinear and biquadratic interactions that are used to model the magnetic structure in conventional metallic multilayers. A model that couples the LSMO layers to a helical spin state within the LNO fits the observed behavior. We propose that the spin-helix results from the interaction between a spatially varying spin susceptibility within the LNO and interfacial charge transfer that creates localized Ni2+ states. This provides a new approach to engineering non-collinear spin textures in metallic oxide heterostructures that can be exploited in devices based on both spin and charge transport.

cond-mat.mtrl-sci

Isoscalar Giant Resonance Strengths in $^{32}$S and possible excitations of superdeformed and $^{28}$Si + $α$ cluster bandheads

Isoscalar giant resonances and low spin states in $^{32}$S have been measured with inelastic $α$ scattering at extremely forward angles including zero degrees at E$_α$ = 386 MeV. By applying the multipole decomposition analysis, various excited states are classified according to their spin and parities (J$^π$), and are discussed in relation to the super deformed and $^{28}$Si + $α$ cluster bands.

nucl-ex

Unusual Resistance Hysteresis in n-Layer Graphene Field Effect Transistors Fabricated on Ferroelectric Pb(Zr_0.2Ti_0.8)O_3

We have fabricated n-layer graphene field effect transistors on epitaxial ferroelectric Pb(Zr_0.2Ti_0.8)O_3 (PZT) thin films. At low gate voltages, PZT behaves as a high-k dielectric with k up to 100. An unusual resistance hysteresis occurs in gate sweeps at high voltages, with its direction opposite to that expected from the polarization switching of PZT. The relaxation of the metastable state is thermally activated, with an activation barrier of 50-110 meV and a time constant of 6 hours at 300 K. We attribute its origin to the slow dissociation/recombination dynamics of water molecules adsorbed at the graphene-PZT interface. This robust hysteresis can potentially be used to construct graphene-ferroelectric hybrid memory devices.

cond-mat.mes-hall

Origin of the magnetoelectric coupling effect in Pb(Zr0.2Ti0.8)O3/La0.8Sr0.2MnO3 multiferroic heterostructures

The electronic valence state of Mn in Pb(Zr0.2Ti0.8)O3/La0.8Sr0.2MnO3 multiferroic heterostructures is probed by near edge x-ray absorption spectroscopy as a function of the ferroelectric polarization. We observe a temperature independent shift in the absorption edge of Mn associated with a change in valency induced by charge carrier modulation in the La0.8Sr0.2MnO3, demonstrating the electronic origin of the magnetoelectric effect. Spectroscopic, magnetic, and electric characterization shows that the large magnetoelectric response originates from a modified interfacial spin configuration, opening a new pathway to the electronic control of spin in complex oxide materials.

cond-mat.mtrl-sci

Proton decay from the isoscalar giant dipole resonance in $^{58}$Ni

Proton decay from the 3$\hbarω$ isoscalar giant dipole resonance (ISGDR) in $^{58}$Ni has been measured using the ($α,α'p$) reaction at a bombarding energy of 386 MeV to investigate its decay properties. We have extracted the ISGDR strength under the coincidence condition between inelastically scattered $α$ particles at forward angles and decay protons emitted at backward angles. Branching ratios for proton decay to low-lying states of $^{57}$Co have been determined, and the results compared to predictions of recent continuum-RPA calculations. The final-state spectra of protons decaying to the low-lying states in $^{57}$Co were analyzed for a more detailed understanding of the structure of the ISGDR. It is found that there are differences in the structure of the ISGDR as a function of excitation energy.

nucl-ex