SearcharxivSearch

arXiv subjects

J. I. Collar

Publications and source records attributed to J. I. Collar.

At least 19 recordsLinked to original sources

Scintillation response of cryogenic CsI to few-keV and sub-keV nuclear recoils

Monochromatic neutron emissions from photonuclear sources $^{88}$Y/Be and $^{124}$Sb/Be are employed to obtain the response of pure (undoped) cesium iodide at 80 K. The use of a low-noise, high-quantum-efficiency avalanche photodiode in combination with a novel waveshifter results in a 70 eV analysis threshold. This reach allows to observe signals from sub-keV nuclear recoils originating in neutron scattering. The extracted quenching factor drops much faster towards low energy than the extrapolation of a model developed for room-temperature CsI[Na]. We comment on the impact of our measurement on planned use of cryogenic CsI in neutrino physics and dark matter experiments.

physics.ins-det

Coherent Elastic Neutrino-Nucleus Scattering at the Japan Proton Accelerator Research Complex

The Japan Proton Accelerator Research Complex (J-PARC) currently delivers a 1 MW, 3 GeV proton beam to the Materials and Life Science Experimental Facility (MLF). Power is expected to increase to 1.3 MW, driven by the needs of Hyper-Kamiokande. As a result, the MLF presently provides the highest neutron yield of any spallation source, while potentially holding the best current and foreseeable conditions for Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) experimentation. We explore this potential, using as examples detector technologies presently funded for construction and under development. We quantify their sensitivity to a rich variety of particle physics scenarios, finding that very-high-statistics CE$ν$NS measurements with significant sensitivity to relevant scenarios are feasible at this facility within the next few years.

hep-ph

Absorption of Fermionic Dark Matter in the PICO-60 C$_{3}$F$_{8}$ Bubble Chamber

Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a non-relativistic effective field theory framework. An analysis of data from the PICO-60 C$_{3}$F$_{8}$ bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/$\textit{c}^2$ and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.

hep-ex

Cryogenic cesium iodide as a potential PET material

Total Body PET (TBPET) scanners have recently demonstrated the ability to significantly reduce both acquisition time and the administered radioactive dose, thanks to their increased sensitivity. However, their widespread adoption is limited by the high costs associated with the current available systems. Cesium iodide (CsI), though historically less favored for PET due to its lower stopping power and light yield compared to crystals like LYSO, shows remarkable improvement when operated at cryogenic temperatures ($\sim$100 K). Under these conditions, CsI light yield rises dramatically to about 100 photons/keV, providing excellent energy resolution and good coincidence time resolution at a lower cost - typically 3 to 5 times cheaper than other crystals at parity of radiation length. In our study, we measured the light yield, the energy resolution and the coincidence time resolution as a function of temperature for two pure CsI crystals read out by a pair of silicon photomultipliers (SiPMs). An energy resolution of 6.3% FWHM and a coincidence time resolution of 1.84 ns at 511 keV were achieved at a temperature of 104 K. These results point towards the potential of cryogenic CsI as a cost-effective, high-performance material for TBPET scanners.

physics.ins-det

Particle Physics at the European Spallation Source

Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).

physics.ins-det

Search for a Non-Relativistic Boson in Two-Body Antimuon Decay

We demonstrate the feasibility of probing the charged lepton flavor violating decay $μ^{+}\!\!\rightarrow \!e^{+} X^{0}$ for the presence of a slow-moving neutral boson $X^{0}$ capable of undergoing gravitational binding to large structures, and as such able to participate in some cosmological scenarios. A short exposure to surface antimuons from beamline M20 at TRIUMF generates a branching ratio limit of $\lesssim 10^{-5}$. This is comparable or better than previous searches for this channel, although in a thus-far unexplored region of $X^{0}$ phase space very close to the kinematic limit of the decay. The future improved sensitivity of the method using a customized p-type point contact germanium detector is described.

hep-ph

New Measurements of $^{71}$Ge Decay: Impact on the Gallium Anomaly

A dedicated high-statistics measurement of the $^{71}$Ge half-life is found to be in accurate agreement with an accepted value of 11.43$\pm$0.03 d, eliminating a recently proposed route to bypass the "gallium anomaly" affecting several neutrino experiments. Our data also severely constrain the possibility of $^{71}$Ge decay to low-energy excited levels of the $^{71}$Ga daughter nucleus as a solution to this puzzle. Additional unpublished measurements of this decay are discussed. Following the incorporation of this new information, the gallium anomaly survives with high statistical significance.

nucl-ex

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

astro-ph.CO

Measurement of Coherent Elastic Neutrino-Nucleus Scattering from reactor antineutrinos

The 96.4 day exposure of a 3 kg ultra-low noise germanium detector to the high flux of antineutrinos from a power nuclear reactor is described. A very strong preference ($p<1.2\times10^{-3}$) for the presence of a coherent elastic neutrino-nucleus scattering (CE$ν$NS) component in the data is found, when compared to a background-only model. No such effect is visible in 25 days of operation during reactor outages. The best-fit CE$ν$NS signal is in good agreement with expectations based on a recent characterization of germanium response to sub-keV nuclear recoils. Deviations of order 60\% from the Standard Model CE$ν$NS prediction can be excluded using present data. Standing uncertainties in models of germanium quenching factor, neutrino energy spectrum, and background are examined.

hep-ex

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

physics.ins-det

Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

astro-ph.CO

Comments on "Direct measurement of the ionization quenching factor of nuclear recoils in germanium in the keV energy range"

We examine a recent measurement of the quenching factor (QF) in germanium at 80 K, noticing a number of inconsistencies capable of affecting a claimed agreement with Lindhard's ion-stopping formalism in the sub-keV nuclear recoil energy regime. Namely, an underestimated uncertainty in the energy scale and a missing correction for a large instrumental non-linearity in this scale able to severely distort the QF behavior at low energy, favoring reduced values. The discussion is expanded to inspect the impact of QF model selection on a study of neutrino electromagnetic properties using CE$ν$NS data that supports a non-zero electric charge at the 3.5 $σ$ level.

physics.ins-det

First results from a search for coherent elastic neutrino-nucleus scattering (CE$ν$NS) at a reactor site

The deployment of a low-noise 3 kg p-type point contact germanium detector at the Dresden-II power reactor, 8 meters from its 2.96 GW$_{th}$ core, is described. This location provides an unprecedented (anti)neutrino flux of 8.1$\times 10^{13} ~\bar{ν_{e}}/$cm$^{2}$s. When combined with the 0.2 keV$_{ee}$ detector threshold achieved, a first measurement of CE$ν$NS from a reactor source appears to be within reach. We report on the characterization and abatement of backgrounds during initial runs, deriving improved limits on extensions of the Standard Model involving a light vector mediator, from preliminary data.

hep-ex

New Experimental Constraints in a New Landscape for Composite Dark Matter

Certain strongly interacting dark matter candidates could have evaded detection, and much work has been done on constraining their parameter space. Recently, it was shown theoretically that the scattering cross section for $m_χ\gtrsim 1$ GeV pointlike dark matter with a nucleus cannot be significantly larger than the geometric cross section of the nucleus. This realization closes the parameter space for pointlike strongly interacting dark matter. However, strongly interacting dark matter is still theoretically possible for composite particles, with much parameter space open. We set new, wide-ranging limits based on data from a novel detector at the University of Chicago. Backgrounds are greatly suppressed by requiring coincidence detection between two spatially separated liquid-scintillator modules. For dark matter ($v \sim 10^{-3}$c), the time of flight would be $\sim 2~μ{\rm s}$, whereas for cosmic rays, it would be $\sim 2~{\rm ns}$. We outline ways to greatly increase sensitivity at modest costs.

hep-ex

Germanium response to sub-keV nuclear recoils: a multipronged experimental characterization

Germanium is the detector material of choice in many rare-event searches looking for low-energy nuclear recoils induced by dark matter particles or neutrinos. We perform a systematic exploration of its quenching factor for sub-keV nuclear recoils, using multiple techniques: photo-neutron sources, recoils from gamma-emission following thermal neutron capture, and a monochromatic filtered neutron beam. Our results point to a marked deviation from the predictions of the Lindhard model in this mostly unexplored energy range. We comment on the compatibility of our data with low-energy processes such as the Migdal effect, and on the impact of our measurements on upcoming searches.

nucl-ex

Response of undoped cryogenic CsI to low-energy nuclear recoils

The bright scintillation of pure CsI operated at liquid-nitrogen temperature makes of this material a promising dark matter and neutrino detector. We present the first measurement of its quenching factor for nuclear recoils. Our findings indicate it is indistinguishable from that for sodium-doped CsI at room temperature. Additional properties such as light yield, afterglow, scintillation decay properties for electron and nuclear recoils, and energy proportionality are studied over the \mbox{108-165 K} temperature range, confirming the vast potential of this medium for rare-event searches.

physics.ins-det

A search for a cosmologically-relevant boson in muon decay

Experiments looking for a lepton flavor-violating decay $μ^{+}\!\!\rightarrow \!e^{+} X^{0}$ are reviewed in light of present-day germanium detector technology, with an eye on scenarios where a long-lived, slow-moving massive boson $X^{0}$ might have a cosmological impact. A broad swath of interesting, unexplored parameter space very close to the kinematic limit of the decay is found to be within the reach of a new proposed search. A number of possible roles for $X^{0}$ in past and present epochs can be investigated.

nucl-ex