Searcharxiv⌕ Search

arXiv · 2609.36342

A portable neutron scatter camera with isotropic sensitivity

Abstract

We describe the design and characterization of a neutron scatter camera specifically developed for the study of neutron fields (flux, energy, direction) in experimental areas of spallation facilities, where multiple neutron sources can simultaneously contribute. A combination of hardware and logic triggers provides the isotropic response required for this application. Neutron source locations are accurately reconstructed on images from a built-in 360$^\circ$ panoramic camera. The full understanding of neutron fields that the device provides can be used for site selection and abatement of neutron backgrounds affecting sensitive instruments such as coherent elastic neutrino-nucleus scattering (CE$ν$NS) detectors to be located at the upcoming European Spallation Source.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. G. Yoon, L. Larizgoitia, C. M. Lewis, F. Monrabal, J. I. Collar. 2026-09-28. A portable neutron scatter camera with isotropic sensitivity. https://arxiv.org/abs/2609.36342

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development and Performance Study of a Capillary Liquid Scintillator Neutron Detector

Capillary liquid scintillator detectors are promising for high-resolution neutron imaging, yet experimental data on their light spread mechanism and spatial performance remain limited. Here, we report a neutron detector based on a hexagonal capillary array filled with EJ-309 liquid scintillator, with an inner diameter of about 50 um and a camera readout of 9 um pixels. Laser experiments show that the FWHM of the full light spot decreases from 260 um to 90 um with a metal light absorber, confirming effective suppression of lateral light spread. Using an AmBe neutron source, an effective field of view with a 5-sigma threshold was established from background frames. For single-capillary events, the pulse height spectrum follows a Landau distribution with a most probable value of 0.133 +/- 0.001 (stat.), and the intrinsic detection efficiency is 10.07% +/- 1.26% (stat.) +/- 1.43% (syst.), corresponding to about 13.55% when normalized to the active liquid scintillator area. The point spread function core yields a radial FWHM of 12.8 um and a centroid positioning precision of approximately 5.5 um (1 sigma), while the intrinsic position resolution is limited by the capillary pitch to 54 um. Linearity is good for 1 to 2 capillaries, with deviation appearing for 2 to 3 capillaries due to additional capture of spread light. These results provide experimental basis and physical understanding for imaging applications of capillary liquid scintillator neutron detectors.

physics.ins-det↗

Development of an Extensible Unified Control System Using the STARS Framework and Common Commands for Detector Control

A zooming optical system comprising two Fresnel zone plates (FZPs) was developed and installed at the AR-NE1A beamline of the Photon Factory, High Energy Accelerator Research Organization (KEK), Japan. To ensure reliable and versatile operation, we implemented a dedicated control architecture based on the Simple Transmission and Retrieval System (STARS) framework and the newly proposed STARS Common Commands for Detector Control (CCDC)---a data-acquisition (DAQ) state model and command set designed specifically for detector control. The system serves both as a practical control system for the zooming optics and as a demonstration of modular extensibility using STARS and detector interoperability through CCDC. The system has been commissioned, and its performance has been verified at the AR-NE1A beamline. The architecture enables flexible configuration of optical components and provides a unified interface for both routine operation and advanced experimental protocols.

physics.ins-det↗

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of $2.94\pm0.05_{\text{stat}}\pm0.74_{\text{syst}}$~eV using a CaWO$_4$ based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.

physics.ins-det↗