Searcharxiv⌕ Search

arXiv subjects

J. Monroe

Publications and source records attributed to J. Monroe.

At least 37 records · Page 2Linked to original sources

Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.

physics.ins-det↗

First operation of an ALICE OROC operated in high pressure Ar-CO$_{2}$ and Ar-CH$_{4}$

New neutrino-nucleus interaction cross-section measurements are required to improve nuclear models sufficiently for future long-baseline neutrino experiments to meet their sensitivity goals. A time projection chamber (TPC) filled with a high-pressure gas is a promising detector to characterise the neutrino sources planned for such experiments. A gas-filled TPC is ideal for measuring low-energy particles as they travel much further in gas than solid or liquid neutrino detectors. Using a high-pressure gas increases the target density, resulting in more neutrino interactions. This paper will examine the suitability of multiwire proportional chambers (MWPCs) taken from the ALICE TPC to be used as the readout chambers of a high-pressure gas TPC. These chambers were previously operated at atmospheric pressure. We tested one such MWPC at up to almost 5 bar absolute (barA) with the UK high-pressure test stand at Royal Holloway, University of London. This paper reports the successful operation of an ALICE TPC outer readout chamber (OROC) at pressures up to 4.8 bar absolute with Ar-CH$_{4}$ mixtures with a CH$_{4}$ content between 2.8% and 5.0%, and so far up to 4 bar absolute with Ar-CO$_{2}$ (90-10). We measured the charge gain of this OROC using signals induced by an $^{55}$Fe source. The largest gain achieved at 4.8 bar was $64\pm2)\cdot10^{3}$ at stable conditions with an anode wire voltage of 2990 V in Ar-CH$_{4}$ (95.9-4.1). In Ar-CO$_{2}$ a gain of $(4.2\pm0.1)\cdot10^{3}$ was observed at an anode voltage of 2975 V at 4 barA gas pressure. Based on all our gain measurements, we extrapolate that, at the 10 barA pressure necessary to fit 1 tonne of gas into the ALICE TPC volume, a gain of 5000 in Ar-CO$_{2}$ (90-10) (10000 in Ar-CH$_{4}$ with $\sim\!$ 4% CH$_{4}$ content) may be achieved with an OROC anode voltage of 4.2 V ($\sim\!$ 3.1 kV).

physics.ins-det↗

Snowmass2021 Cosmic Frontier: The landscape of low-threshold dark matter direct detection in the next decade

The search for particle-like dark matter with meV-to-GeV masses has developed rapidly in the past few years. We summarize the science case for these searches, the recent progress, and the exciting upcoming opportunities. Funding for Research and Development and a portfolio of small dark matter projects will allow the community to capitalize on the substantial recent advances in theory and experiment and probe vast regions of unexplored dark-matter parameter space in the coming decade.

hep-ph↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

hep-ex↗

Search for low-mass dark matter WIMPs with 12 ton-day exposure of DarkSide-50

We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately model the background rate and spectra down to 0.06 keV$_{er}$. A 90% C.L. exclusion limit for the spin-independent cross section of 3 GeV/c$^2$ mass WIMP on nucleons is set at 6$\times$10$^{-43}$ cm$^2$, about a factor 10 better than the previous DarkSide-50 limit. This analysis extends the exclusion region for spin-independent dark matter interactions below the current experimental constraints in the $[1.2, 3.6]$ GeV/c$^2$ WIMP mass range.

hep-ex↗

Search for dark matter-nucleon interactions via Migdal effect with DarkSide-50

Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12306 $\pm$ 184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c$^2$. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below $3.6$ GeV/c$^2$.

hep-ex↗

Search for dark matter particle interactions with electron final states with DarkSide-50

We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark photon kinetic mixing parameter $κ$. We also set the first dark matter direct-detection constraints on the mixing angle $\left|U_{e4}\right|^2$ for keV sterile neutrinos.

hep-ex↗

PlomBOX -- development of a low-cost CMOS device for environmental monitoring

This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluoresce or change colour when in the presence of lead. A genetically modified strain of Escherichia coli sensitive to lead concentrations up to 10 ppb is being developed. This constitutes the biosensor that fluoresces in proportion to the presence of lead. b) Bacteria response is imaged using a microprocessor (ESP32) with a camera module. This constitutes the optical metrology component of the PlomBOX. c) Data acquisition and control of the PlomBOX is achieved through a Bluetooth connection with the PlomApp, a custom-developed mobile phone application. Data are sent from the PlomApp to a database where a bespoke automated analysis software provides a result of the lead concentration in a sample of water. This paper reports on the instrumentation challenges of developing the electronics for the PlomBOX and on the first prototype.

physics.ins-det↗

Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector

DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.

astro-ph.CO↗

First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.

astro-ph.CO↗

Characterisation of SiPM Photon Emission in the Dark

In this paper, we report on the photon emission of Silicon Photomultipliers (SiPMs) from avalanche pulses generated in dark condition, with the main objective of better understanding the associated systematics for next-generation, large area, SiPM-based physics experiments. A new apparatus for spectral and imaging analysis was developed at TRIUMF and used to measure the light emitted by the two SiPMs considered as photo-sensor candidates for the nEXO neutrinoless double-beta decay experiment: one Fondazione Bruno Kessler (FBK) VUV-HD Low Field (LF) Low After Pulse (Low AP) (VUV-HD3) SiPM, and one Hamamatsu Photonics K.K. (HPK) VUV4 Multi-Pixel Photon Counter (MPPC). Spectral measurements of their light emission were taken with varying over-voltage in the wavelength range of 450--1020\,nm. For the FBK VUV-HD3, at an over-voltage of $12.1\pm1.0$\,V, we measure a secondary photon yield (number of photons ($γ$) emitted per charge carrier ($e^{-}$)) of $(4.04\pm0.02)\times 10^{-6}$ $γ/e^{-}$. The emission spectrum of the FBK VUV-HD3 contains an interference pattern consistent with thin-film interference. Additionally, emission microscopy images (EMMIs) of the FBK VUV-HD3 show a small number of highly localized regions with increased light intensity (hotspots) randomly distributed over the SiPM surface area. For the HPK VUV4 MPPC, at an over-voltage of $10.7\pm1.0$\,V, we measure a secondary photon yield of $(8.71\pm0.04)\times 10^{-6}$ $γ/e^{-}$. In contrast to the FBK VUV-HD3, the emission spectra of the HPK VUV4 don't show an interference pattern -- most likely due to a thinner surface coating. EMMIs of the HPK VUV4 also reveal a larger number of hotspots compared to the FBK VUV-HD3, especially in one of the corners of the device.

physics.ins-det↗

Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.

physics.ins-det↗

Search for $hep$ solar neutrinos and the diffuse supernova neutrino background using all three phases of the Sudbury Neutrino Observatory

A search has been performed for neutrinos from two sources, the $hep$ reaction in the solar $pp$ fusion chain and the $ν_e$ component of the diffuse supernova neutrino background (DSNB), using the full dataset of the Sudbury Neutrino Observatory with a total exposure of 2.47 kton-years after fiducialization. The $hep$ search is performed using both a single-bin counting analysis and a likelihood fit. We find a best-fit flux that is compatible with solar model predictions while remaining consistent with zero flux, and set a one-sided upper limit of $Φ_{hep} < 30\times10^{3}~\mathrm{cm}^{-2}~\mathrm{s}^{-1}$ [90% credible interval (CI)]. No events are observed in the DSNB search region, and we set an improved upper bound on the $ν_e$ component of the DSNB flux of $Φ^\mathrm{DSNB}_{ν_e} < 19~\textrm{cm}^{-2}~\textrm{s}^{-1}$ (90% CI) in the energy range $22.9 < E_ν< 36.9$~MeV.

hep-ex↗

Characterization of Germanium Detectors for the First Underground Laboratory in Mexico

This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike $γ$-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution, and full energy peak efficiencies are reported from measurements performed on surface laboratories. The detectors will be deployed in a $γ$-ray assay facility that will be located in the first underground laboratory in Mexico, Laboratorio Subterráneo de Mineral del Chico (LABChico), in the Comarca Minera UNESCO Global Geopark

physics.ins-det↗

Off-Axis Characterisation of the CERN T10 Beam for low Momentum Proton Measurements with a High Pressure Gas Time Projection Chamber

We present studies of proton fluxes in the T10 beamline at CERN. A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon. To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at oscillation experiments, i.e., near 0.1 GeV of kinetic energy, methods of moderating the T10 beam were employed: the dual technique of moderating the beam with acrylic blocks and measuring scattered protons off the beam axis was used to decrease the kinetic energy of incident protons, as well as change the proton/minimum ionising particle (MIP) composition of the incident flux. Measurements of the beam properties were made using time of flight systems upstream and downstream of the TPC. The kinetic energy of protons reaching the TPC was successfully changed from $\sim0.3$ GeV without moderator blocks to less than 0.1 GeV with four moderator blocks (40 cm path length). The flux of both protons and MIPs off the beam axis was increased. The ratio of protons to MIPs vary as a function of the off-axis angle allowing for possible optimisation of the detector to select the type of required particles. Simulation informed by the time of flight measurements show that with four moderator blocks placed in the beamline, ($5.6 \pm 0.1$) protons with energies below 0.1 GeV per spill traversed the active TPC region. Measurements of the beam composition and energy are presented.

physics.ins-det↗

The liquid-argon scintillation pulseshape in DEAP-3600

DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD. The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response. TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.

physics.ins-det↗

Cosmogenic Neutron Production at the Sudbury Neutrino Observatory

Neutrons produced in nuclear interactions initiated by cosmic-ray muons present an irreducible background to many rare-event searches, even in detectors located deep underground. Models for the production of these neutrons have been tested against previous experimental data, but the extrapolation to deeper sites is not well understood. Here we report results from an analysis of cosmogenically produced neutrons at the Sudbury Neutrino Observatory. A specific set of observables are presented, which can be used to benchmark the validity of GEANT4 physics models. In addition, the cosmogenic neutron yield, in units of $10^{-4}\;\text{cm}^{2}/\left(\text{g}\cdotμ\right)$, is measured to be $7.28 \pm 0.09\;\text{stat.} ^{+1.59}_{-1.12}\;\text{syst.}$ in pure heavy water and $7.30 \pm 0.07\;\text{stat.} ^{+1.40}_{-1.02}\;\text{syst.}$ in NaCl-loaded heavy water. These results provide unique insights into this potential background source for experiments at SNOLAB.

hep-ex↗

Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB

DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.

astro-ph.CO↗