SearcharxivSearch

arXiv subjects

J. Monroe

Publications and source records attributed to J. Monroe.

At least 19 recordsLinked to original sources

Measurement of the muon flux at SNOLAB using the DEAP-3600 experiment

A direct measurement of the muon flux at SNOLAB is performed using the DEAP-3600 experiment, located 2 km underground at SNOLAB near Sudbury, Canada. Primarily designed for the direct detection of weakly interacting massive particles (WIMPs), a dark matter candidate, DEAP-3600 consists of an inner spherical acrylic vessel containing a liquid argon target; this vessel is enclosed within a steel shell which is submerged in an instrumented water tank, serving as a muon veto for the dark matter search. The muon flux measurement is performed using a cut-and-count analysis of events observed in the muon veto detector and of events which are coincident between the muon veto and the liquid argon target. The requirement that muons traverse both the water and liquid argon minimizes instrumental backgrounds and systematic uncertainties. Using data collected from November 2016 to March 2020, the muon flux is measured by this coincidence analysis to be $(3.71 \pm 0.25_{\textrm{stat}} \pm 0.09_{\textrm{sys}}) \times 10^{-10}\, \mu/$cm$^2$/s. The standalone measurement using muon veto data only is compatible within uncertainties. Both measurements agree with the previous result by the SNO experiment and with simulations carried out using the MUTE software. These results provide an important benchmark for future rare-event searches at the SNOLAB facility.

hep-ex

First evidence of neutrino absorption on argon using $^{8}$B solar neutrinos in DEAP-3600

We report experimental evidence for electron neutrino charged-current interactions (neutrino absorption, CC $\nu_e$) from $^{8}$B solar neutrinos on $^{40}$Ar using an exposure of ($7.29 \pm 0.05$) tonne$\cdot$years in the DEAP-3600 detector. A region of interest (ROI) of 10.5-13.0 MeV reconstructed energy calibrated on single-peak events, corresponding to incident neutrino energy in 12.0-14.5 MeV, is used for this measurement. We observe 5 single-peak and 1 double-peak neutrino-like events consistent with the $^{8}$B solar neutrino energy spectrum in the ROI after correcting for nonlinearities in the detector response at high energies. With an expected background of $0.48~^{+0.16}_{-0.15}$ events, the data correspond to a significance of $4.0\,\sigma$ with respect to the background-only hypothesis. We report an energy-averaged cross section of $(4.0~^{+2.0}_{-1.6}~\mathrm{(stat)}~^{+0.8}_{-0.7}~\mathrm{(sys)})\times 10^{-41}\,\mathrm{cm}^2$ in the ROI for the CC $\nu_{e}$ signal, a factor $(2.4~^{+1.3}_{-1.0})$ higher than predicted by Bhattacharya, Goodman and Garc\'ia (2009).

hep-ex

Dark Matter Search with the DEAP-3600 Detector using the Profile Likelihood Ratio Method

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is based on three parameters: estimated energy, pulse-shape discrimination parameter, and reconstructed position within the detector. Using this method, the expected signal sensitivity of DEAP-3600 benefits from an increased fiducial volume and improved event selection acceptance. Alpha-decays from a small number of dust particulates circulating within the liquid argon target are the dominant source of background events and limit the sensitivity of this search. This result provides improved exclusion upper limits on the WIMP-nucleon spin-independent cross section on liquid argon for WIMP masses between 20 GeV/$c^{2}$ and 100 GeV/$c^{2}$. At 100 GeV/$c^{2}$ the observed limit is 3.4 $\times$ 10$^{-45}$ cm$^2$ at 90% confidence level.

hep-ex

Probing the Dark Matter EFT with QUEST-DMC: Projected Sensitivities and Attenuation Ceilings

This proceedings contribution summarises projected constraints from the QUEST-DMC concept, a surface-based direct-detection experiment using superfluid $^3$He operated below the millikelvin regime and instrumented with nanomechanical resonators read out by SQUIDs. The low recoil-energy threshold (down to sub-eV for the SQUID configuration) enables sensitivity to sub-GeV dark matter across a wide set of interaction structures beyond the canonical spin-independent and spin-dependent limits. We present projections in the non-relativistic Effective Field Theory (EFT) framework, scanning the standard set of fourteen Galilean-invariant operators and expressing reach in terms of effective dark matter-nucleon (or dark matter-neutron) cross sections. Because QUEST-DMC operates at the surface, we also account for suppression of the incident flux due to scattering in the atmosphere and Earth, which produces an interaction-dependent sensitivity ceiling at large couplings. Finally, we outline how the non-relativistic results map onto representative relativistic EFT dark matter-nucleon bilinears, enabling a compact interpretation of the projected reach in terms of UV-motivated coupling structures.

hep-ph

First Nuclear Ultra-Heavy Dark Matter Search in Argon Time Projection Chambers with the DarkSide-50 Experiment

We report the first search for nuclear ultra-heavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles (WIMPs), nuclear UHDM candidates may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth's overburden, we apply selection criteria optimized for multi-scatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of $m_\chi = 10, 50, 100, 500 \, \mathrm{GeV/c^2}$ are presented.

hep-ex

Characterisation of silicon photomultipliers in a dilution refrigerator down to 9.4 mK towards a cryogenic cosmic-ray muon veto system

We report the characterisation of a FBK NUV-HD-cryo silicon photomultiplier (SiPM) sensor operated in a 9.4 $\pm$ 0.2 mK environment inside a dilution refrigerator, towards the development of a cryogenic cosmic ray muon veto system to be operated internal to a dilution refrigerator required for low background experiments such as the QUEST-DMC dark matter search experiment. We characterise the single photon response and the gain (the charge produced per detected photon), the dark count noise rate, and correlated noise contributions as a function of operating voltage. This paper also reports first proof-of-concept measurements of using a SiPM coupled to scintillator internal to a dilution refrigerator, towards detecting high-energy events consistent with candidate cosmic-ray muon signals.

physics.ins-det

Development of superfluid helium-3 bolometry using nanowire resonators with SQUID readout for the QUEST-DMC experiment

Superfluid helium-3 bolometers can be utilised for dark matter direct detection searches. The extremely low heat capacity of the B phase of the superfluid helium-3 at ultra-low temperatures offers the potential to reach world leading sensitivity to spin dependent interactions of dark matter in the sub-GeV/c$^2$ mass range. Here, we describe the development of bolometry using both micron scale and sub-micron diameter vibrating wire resonators, with a SQUID amplifier-based readout scheme. Characterisation of the resonators and bolometer measurements are shown, including the use of non-linear operation and the corresponding corrections. The bolometer contains two vibrating wire resonators, enabling heat injection calibration and simultaneous bolometer tracking measurements. Coincident events measured on both vibrating wire resonators verify their response. We also demonstrate proof of concept frequency multiplexed readout. Development of these measurement techniques lays the foundations for the use of superfluid helium-3 bolometers, instrumented with vibrating nano-mechanical resonators, for future low threshold dark matter searches.

physics.ins-det

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

hep-ex

Dark Matter EFT Landscape Probed by QUEST-DMC

We present the projected sensitivity to non-relativistic Effective Field Theory (EFT) operators for Dark Matter (DM) direct detection using the QUEST-DMC experiment. QUEST-DMC employs superfluid Helium-3 as a target medium and measures energy deposition via nanomechanical resonators with SQUID-based readout to probe DM interactions. The experiment aims to explore new parameter space in the sub-GeV mass range, probing light DM and a broad range of interaction models. We analyse the sensitivity to a complete set of fourteen independent non-relativistic EFT operators, each parameterised by a Wilson coefficient that quantifies the strength of DM interactions with Standard Model particles. For each interaction channel, we determine the corresponding sensitivity ceiling due to attenuation of the DM flux incident on the detector, caused by DM scattering in the Earth and atmosphere. As a key component of this analysis, we provide the mapping between the non-relativistic EFT operators and the relativistic bilinear DM-nucleon interactions, and assess the interaction sensitivity to sub-GeV DM in the QUEST-DMC detector. Our findings demonstrate that QUEST-DMC provides a unique probe of DM interactions, particularly in previously unexplored parameter space for momentum- and velocity-dependent interactions, thereby expanding the search for viable DM candidates beyond traditional weakly interacting massive particles.

hep-ph

Fermionic sub-GeV Dark Matter from evaporating Primordial Black Holes at DarkSide-50

We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic particles, with energies up to hundreds of MeV, can generate detectable signals for masses below $\mathcal{O}(100)$ MeV. The absence of a signal enables setting complementary limits to those derived from cosmological observations and direct detection searches for cosmic ray-boosted dark matter.

hep-ph

Dark Matter Attenuation Effects: Sensitivity Ceilings for Spin-Dependent and Spin-Independent Interactions

Direct detection experiments aimed at uncovering the elusive nature of dark matter (DM) have made significant progress in probing ever lower cross-sections for DM-nucleon interactions. At the same time, an upper limit in the cross-section sensitivity region is present due to DM scattering in the Earth and atmosphere and as a result never reaching the detector. We investigate the impact of this effect for both spin-dependent and spin-independent interactions. In contrast to previous studies that assume a straight line path for DM scattering we employ a semi-analytic diffusion model that takes into account the impact of potentially large angle deviations prevalent for light DM masses. We find that for sufficiently low energy thresholds, this difference in modelling impacts the DM interaction cross-section sensitivity. This study evaluates the impact in the context of the QUEST-DMC experiment, which utilises surface-based detectors with superfluid Helium-3 bolometers to search for sub-GeV DM exploiting low energy threshold. At masses below 1 GeV$/c^2$ the deviation between the two frameworks becomes pronounced. The ceiling sensitivity limit for QUEST-DMC on spin-dependent DM-neutron cross-sections is $\sim 3 \times 10^{-24}$ cm$^2$ using the diffusive framework and approximately doubles with the straight-line path DM scattering. Similarly, for spin-independent DM-nucleon cross-sections, the ceiling limit is $\sim 7.5 \times 10^{-27}$ cm$^2$ under the diffusive framework and also increases about a factor of two with the straight-line path approximation, within the mass range of 0.025-5 GeV$/c^2$.

hep-ph

Direct Measurement of the $^{39}$Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector

The half-life of $^{39}$Ar is measured using the DEAP-3600 detector located 2 km underground at SNOLAB. Between 2016 and 2020, DEAP-3600 used a target mass of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere in a direct-detection dark matter search. Such an argon mass also enables direct measurements of argon isotope properties. The decay of $^{39}$Ar in DEAP-3600 is the dominant source of triggers by two orders of magnitude, ensuring high statistics and making DEAP-3600 well-suited for measuring this isotope's half-life. Use of the pulse-shape discrimination technique in DEAP-3600 allows powerful discrimination between nuclear recoils and electron recoils, resulting in the selection of a clean sample of $^{39}$Ar decays. Observing over a period of 3.4 years, the $^{39}$Ar half-life is measured to be $(302 \pm 8_{\rm stat} \pm 6_{\rm sys})$ years. This new direct measurement suggests that the half-life of $^{39}$Ar is significantly longer than the accepted value, with potential implications for measurements using this isotope's half-life as input.

nucl-ex

Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $\alpha$-Particles in Liquid Argon using DEAP-3600 Data

The knowledge of scintillation quenching of $\alpha$-particles plays a paramount role in understanding $\alpha$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.

physics.ins-det

QUEST-DMC: Background Modelling and Resulting Heat Deposit for a Superfluid Helium-3 Bolometer

We report the results of radioactivity assays and heat leak calculations for a range of common cryogenic materials, considered for use in the QUEST-DMC superfluid 3He dark matter detector. The bolometer, instrumented with nanomechanical resonators, will be sensitive to energy deposits from dark matter interactions. Events from radioactive decays and cosmic rays constitute a significant background and must be precisely modelled, using a combination of material screening and Monte Carlo simulations. However, the results presented here are of wider interest for experiments and quantum devices sensitive to minute heat leaks and spurious events, thus we present heat leak per unit mass or surface area for every material studied. This can inform material choices for other experiments, especially if underground operation is considered where the radiogenic backgrounds will dominate even at shallow depths.

cond-mat.other

Robust Quantum Control in Closed and Open Systems: Theory and Practice

Robust control of quantum systems is an increasingly relevant field of study amidst the second quantum revolution, but there remains a gap between taming quantum physics and robust control in its modern analytical form that culminated in fundamental performance bounds. With certain exceptions such as quantum optical systems that can be modeled as linear stochastic differential equations, quantum systems are not amenable to linear, time-invariant, measurement-based robust control techniques, and thus novel gap-bridging techniques must be developed. This survey is written for control theorists to provide a review of the current state of quantum control and outline the challenges faced in trying to apply modern robust control to quantum systems. We present issues that arise when applying classical robust control theory to quantum systems, typical methods used by quantum physicists to explore such systems and their robustness, as well as a discussion of open problems to be addressed in the field. We focus on general, practical applications and recent work to enable control researchers to contribute to advancing this burgeoning field.

quant-ph

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

hep-ex

QUEST-DMC superfluid $^3$He detector for sub-GeV dark matter

The focus of dark matter searches to date has been on Weakly Interacting Massive Particles (WIMPs) in the GeV/$c^2$-TeV/$c^2$ mass range. The direct, indirect and collider searches in this mass range have been extensive but ultimately unsuccessful, providing a strong motivation for widening the search outside this range. Here we describe a new concept for a dark matter experiment, employing superfluid $^3$He as a detector for dark matter that is close to the mass of the proton, of order 1 GeV/$c^2$. The QUEST-DMC detector concept is based on quasiparticle detection in a bolometer cell by a nanomechanical resonator. In this paper we develop the energy measurement methodology and detector response model, simulate candidate dark matter signals and expected background interactions, and calculate the sensitivity of such a detector. We project that such a detector can reach sub-eV nuclear recoil energy threshold, opening up new windows on the parameter space of both spin-dependent and spin-independent interactions of light dark matter candidates.

hep-ex

Search for dark matter annual modulation with DarkSide-50

Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.

hep-ex