Status of the DAMIC direct dark matter search experiment

The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.

physics.ins-det

The DAMIC dark matter experiment

The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.

physics.ins-det

Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment

We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.

astro-ph.IM

Pulsational frequencies of the eclipsing delta-Scuti star HD 172189

The eclipsing delta-Scuti star HD 172189 is a probable member of the open cluster IC 4756 and a promising candidate target for the CoRoT mission. The detection of pulsation modes is the first step in the asteroseismological study of the star. Further, the calculation of the orbital parameters of the binary system allows us to make a dynamical determination of the mass of the star, which works as an important constraint to test and calibrate the asteroseismological models. From a detailed frequency analysis of 210 hours of photometric data of HD 172189 obtained from the STEPHI XIII campaign we have identified six pulsation frequencies with a confidence level of 99% and a seventh with a 65% confidence level in the range between 100-300 uHz. In addiction, three eclipses were observed during the campaign, allowing us to improve the determination of the orbital period of the system.

astro-ph

Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap of 0.5 mm. The small pixel size makes the detector ideal for high gradient beam profiles like those present in Intensity Modulated Radiation Therapy (IMRT) and radiosurgery. As read-out electronics we use the X-Ray Data Acquisition System (XDAS) with the Xchip developed by the CCLRC. Studies concerning the collection efficiency dependence on the polarization voltage and on the dose rate have been made in order to optimize the device operation. In the first tests we have studied dose rate and energy dependences, and signal reproducibility. Dose rate dependence was found lower than 2.5 % up to 5 Gy min$^{-1}$, and energy dependence lower than 2.1 % up to 20 cm depth in solid water. Output factors and penumbras for several rectangular fields have been measured with the linear array and were compared with the results obtained with a 0.125 cm$^{3}$ air ionization chamber and radiographic film, respectively. Finally, we have acquired profiles for an IMRT field and for a virtual wedge. These profiles have also been compared with radiographic film measurements. All the comparisons show a good correspondence. Signal reproducibility was within a 2% during the test period (around three months). The device has proved its capability to verify on-line therapy beams with good spatial resolution and signal to noise ratio.

physics.med-ph

Multi-site, multi-technique survey of Gamma Doradus candidates

We present the first results of a 2-year high-resolution spectroscopy campaign of 59 candidate Gamma Doradus stars which were mainly discovered from the HIPPARCOS astrometric mission. More than 60 % of the stars present line profile variations which can be interpreted as due to pulsation related to Gamma Doradus stars. For all stars we also derived the projected rotation velocity (up to more than 200 km\s). The amplitude ratios 2K/Delta m for the main HIPPARCOS frequency are in the range 35 - 96 (km\s)\mag. Less than 50 % of the candidates are possible members of binary systems, with 20 stars being confirmed Gamma Doradus. At least 6 stars present composite spectra, and in all but one case (for which only one spectrum could be obtained), the narrow component shows line profile variations, pointing towards an uncomfortable situation if this narrow component originates from a shell surrounding the star. This paper is the first of a series concerning mode identification using both photometric and spectroscopic methods for the confirmed Gamma Doradus stars of the present sample.

astro-ph

Free ion yield observed in liquid isooctane irradiated by gamma rays. Comparison with the Onsager theory

We have analyzed data on the free ion yield observed in liquid isooctane irradiated by Co60 gamma rays within the framework of the Onsager theory about initial recombination. Several distribution functions describing the electron thermalization distance have been used and compared with the experimental results: a delta function, a Gaussian type function and an exponential function. A linear dependence between free ion yield and external electric field has been found at low electric field values (E<1.2 MV/m) in excellent agreement with the Onsager theory. At higher electric field values we obtain a solution in power series of the external field using the Onsager theory.

physics.ins-det

A two dimensional position sensitive gas chamber with scanned charge transfer readout

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge transfer technique. It has been implemented by using gate strips perpendicularly oriented to the collector strips. This solution reduces considerably the number of electronic readout channels needed to cover large detector areas. The use of a 25 micron thick kapton etched circuit allows high charge transfer efficiency with a low gating voltage, consequently needing a very simple commutating circuit. The present prototype covers 8 x 8 cm^2 with a pixel size of 1.27 x 1.27 mm^2. Depending on the intended use and beam characteristics a smaller effective pixel is feasible and larger active areas are possible. This detector can be used for X-ray or other continuous beam intensity profile monitoring.

physics.ins-det