SearcharxivSearch

arXiv subjects

J. W. Zhang

Publications and source records attributed to J. W. Zhang.

At least 19 recordsLinked to original sources

Absolute frequency measurement of molecular iodine hyperfine transitions at 554 nm and its application to stabilize a 369 nm laser for Yb+ ions cooling

We investigate 13 hyperfine structures of transition lines of 127I2 near 554 nm, namely, the R(50) 22-0, P(46) 22-0, P(121) 24-0, P(69) 25-1, R(146) 25-0, R(147) 28-1, P(160) 26-0, P(102) 26-1, R(96) 23-0, R(49) 22-0, P(45) 22-0, P(92) 23-0, and R(72) 25-1 transitions, and measure their absolute frequencies with an optical frequency comb. A 369 nm frequency-tripled laser is frequency stabilized by locking the 554 nm harmonic-frequency laser to the R(146) 25-0 a15 line of 127I2 via modulation transfer spectroscopy. A frequency stability of 5E-12 is observed over a 1000 s integration time. The measurement of the molecular iodine spectroscopy at 554 nm enriches high-precision experimental data, and also enables theoretical predictions. Meanwhile, the 369 nm frequency-tripled laser stabilized by molecular iodine spectroscopy has wide applications in frequency metrology, and quantum information processing based on Yb+ ions.

physics.atom-ph

Precise determination of ground-state hyperfine splitting and calculation of Zeeman coefficients for 171Yb+ microwave frequency standard

We report precise measurement of the hyperfine splitting and calculation of the Zeeman coefficients of the $^{171}$Yb$^+$ ground state. The absolute hyperfine splitting frequency is measured using high-resolution laser-microwave double-resonance spectroscopy at 0.1 mHz level, and evaluated using more accurate Zeeman coefficients. These Zeeman coefficients are derived using Landé $g_J$ factors calculated by two atomic-structure methods, multiconfiguration Dirac-Hartree-Fock, and multireference configuration interaction. The cross-check of the two calculations ensures an accuracy of the Zeeman coefficients at $10^{-2}$ Hz/G$^2$ level. The results provided in this paper improve the accuracy and reliability of the second-order Zeeman shift correction, thus further improving the accuracy of the microwave frequency standards based on $^{171}$Yb$^+$. The high-precision hyperfine splitting and Zeeman coefficients could also support could also support further experiments to improve the constraints of fundamental constants through clock frequency comparison of the Yb$^+$ system.

physics.atom-ph

$^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard

We reported the realization of a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ bi-species Coulomb crystal comprising $^{174}\mathrm{Yb}^+$ ions as coolant and verified its potential for application as a $^{113}\mathrm{Cd}^+$ microwave frequency standard employing sympathetic cooling.The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The $^{113}\mathrm{Cd}^+$ ions are trapped in the center, which reduces considerably RF heating and excess micromotion to which the $^{113}\mathrm{Cd}^+$ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to $5\times10^{-16}$, which represents an order of magnitude improvement over sympathetic cooled $^{40}\mathrm{Ca}^+$-$^{113}\mathrm{Cd}^+$ crystal. The uncertainty from the second-order Zeeman effect, which contributes the largest uncertainty to the microwave-ion frequency standard, is reduced to $4\times10^{-16}$. The relevant AC Stark shift uncertainty is estimated to be $4\times10^{-19}$. These results indicate using $^{174}\mathrm{Yb}^+$ as coolant ions for $^{113}\mathrm{Cd}^+$ is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ two-component crystal.

physics.atom-ph

Second-order Doppler frequency shifts of trapped ions in a linear Paul trap

The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a new model to accurately evaluate the total SODFS for ion microwave clocks. The effectiveness of the model has been verified both in simulation and experiment, especially for ion ensemble with temperature less than 100 mK. We believe that our new model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.

physics.atom-ph

High-Performance Microwave Frequency Standard Based on Sympathetically Cooled Ions

The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically-cooled ion microwave frequency standard has seldom been studied before. This paper reports the first sympathetically-cooled ion microwave frequency standard in a Paul trap. Using laser-cooled ${}^{40}\mathrm{Ca}^{+}$ as coolant ions, ${}^{113}\mathrm{Cd}^{+}$ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48 \times 10^{-13}/τ^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\times 10^{-14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.

physics.atom-ph

Determination of hyperfine splittings and Landé $g_J$ factors of $5s~^2S_{1/2}$ and $5p~^2P_{1/2,3/2}$ states of $^{111,113}$Cd$^+$ for a microwave frequency standard

Regarding trapped-ion microwave-frequency standards, we report on the determination of hyperfine splittings and Landé $g_J$ factors of $^{111,113}$Cd$^+$. The hyperfine splittings of the $5p~^2P_{3/2}$ state of $^{111,113}$Cd$^+$ ions were measured using laser-induced fluorescence spectroscopy. The Cd$^+$ ions were confined in a linear Paul trap and sympathetically cooled by Ca$^+$ ions. Furthermore, the hyperfine splittings and Landé $g_J$ factors of the $5s~^2S_{1/2}$ and $5p~^2P_{1/2,3/2}$ levels of $^{111,113}$Cd$^+$ were calculated with greater accuracy using the multiconfiguration Dirac--Hartree--Fock scheme. The measured hyperfine splittings and the Dirac--Hartree--Fock calculation values were cross-checked, thereby further guaranteeing the reliability of our results. The results provided in this work can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, and subsequently the stability and accuracy of the microwave frequency standard based on trapped Cd$^+$ ions.

physics.atom-ph

Sympathetic cooling of a large ${}^{113}\mathrm{Cd}^{+}$ ion crystal with ${}^{40}\mathrm{Ca}^{+}$ in a linear Paul trap

We have sympathetically cooled and crystallized ${}^{113}\mathrm{Cd}^{+}$ ions with laser-cooled ${}^{40}\mathrm{Ca}^{+}$ ions, and directly observed the complete large bicrystal structure in a linear Paul trap. The large two-component crystal contains up to $3.5\times10^3$ ${}^{40}\mathrm{Ca}^{+}$ ions and $6.8\times10^3$ ${}^{113}\mathrm{Cd}^{+}$ ions. The temperature of the crystallized ${}^{113}\mathrm{Cd}^{+}$ ions was measured to be as low as 41 mK with a large mass ratio. Moreover, we have studied several properties and structures of the ultracold sample. The factors affecting the sympathetic cooling effect were studied, including the electrical parameters and the number ratio between laser-cooled ions and sympathetically-cooled ions. The results of this paper enrich the experimental research of large two-component ion crystals, and the ultracold sample of ${}^{113}\mathrm{Cd}^{+}$ ions makes it possible to further improve the accuracy of the cadmium-ion microwave frequency standard.

physics.atom-ph

Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal

We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to $8.5 \times {10^{ - 13}}/\sqrt τ$ for averaging times between 10 and 1000 s.

physics.atom-ph

Multidimensional King-plot analysis for accurate extraction of Cd nuclear charge radii: a challenge for nuclear structure theory

High-accuracy determination of isotope shift factors, which plays a crucial role in accurate extraction of nuclear charge radius, is well-known to be challenging experimentally and theoretically. Nonetheless, based on an accurate measurement of the isotope shifts for the Cd$^+$ $5s~^2S_{1/2}-5p~^2P_{3/2}$ and the Cd $5s^2~^1S_0-5s5p~^1P_1$ transition, a multidimensional King-plot analysis is performed to extract the atomic field shift and mass shift factors accurately. The results are further cross-checked against results from atomic structure calculations using a high-accuracy configuration interaction and many-body perturbation theory. Combined with previous isotope shifts, nuclear charge radii for $^{100-130}$Cd of the highest accuracy are reported. For the neutron-rich region, accuracies for the charge radii are improved by nearly one order of magnitude. This work provides a coherent and systematic extraction of Cd nuclear charge radii from isotope shifts. The results offer stringent testing and possible challenges to the latest advances in nuclear theory and excellent benchmarking to the atomic structure calculations.

physics.atom-ph

Precision determination of the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions

We measured the ground-state hyperfine splitting of trapped ${}^{113}$Cd${}^{+}$ ions to be 15199862855.02799(27) Hz with a fractional uncertainty of $1.8\times10^{-14}$. The ions were trapped and laser-cooled in a linear quadrupole Paul trap. The fractional frequency stability was measured to be ${4.2} \times 10^{-13}/\sqrtτ $, obtained from Ramsey fringes of high signal-to-noise ratio and taken over a measurement time of nearly 5 hours, which is close to the short-term stability limit estimated from the Dick effect. Our result is consistent with previous reported values, but the measurement precision is four times better than the best result obtained to date.

physics.atom-ph

Single-atom verification of the noise-resilient and fast characteristics of universal nonadiabatic noncyclic geometric quantum gates

Quantum gates induced by geometric phases are intrinsically robust against noise due to their global properties of the evolution paths. Compared to conventional nonadiabatic geometric quantum computation (NGQC), the recently proposed nonadiabatic noncyclic geometric quantum computation (NNGQC) works in a faster fashion, while still remaining the robust feature of the geometric operations. Here, we experimentally implement the NNGQC in a single trapped ultracold $^{40}$Ca$^{+}$ ion for verifying the noise-resilient and fast feature. By performing unitary operations under imperfect conditions, we witness the advantages of the NNGQC with measured fidelities by quantum process tomography in comparison with other two quantum gates by conventional NGQC and by straightforwardly dynamical evolution. Our results provide the first evidence confirming the possibility of accelerated quantum information processing with limited systematic errors even in the imperfect situation.

quant-ph

Single-Atom Verification of the Information-Theoretical Bound of Irreversibility at the Quantum Level

Quantitative measure of disorder or randomness based on the entropy production characterizes thermodynamical irreversibility, which is relevant to the conventional second law of thermodynamics. Here we report, in a quantum mechanical fashion, the first theoretical prediction and experimental exploration of an information-theoretical bound on the entropy production. Our theoretical model consists of a simplest two-level dissipative system driven by a purely classical field, and under the Markovian dissipation, we find that such an information-theoretical bound, not fully validating quantum relaxation processes, strongly depends on the drive-to-decay ratio and the initial state. Furthermore, we carry out experimental verification of this information-theoretical bound by means of a single spin embedded in an ultracold trapped $^{40}$Ca$^{+}$ ion. Our finding, based on a two-level model, is fundamental to any quantum thermodynamical process and indicates much difference and complexity in quantum thermodynamics with respect to the conventionally classical counterpart.

quant-ph

Sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for Microwave Ion Clocks

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured at $90(10)$ mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of $2\times10^{-17}$. Up to $4.2\times10^5$ Cd$^+$ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still $10^5$ Cd$^+$ ions present, indicating that this Ca$^+$--Cd$^+$ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca$^+$ lasers and fluorescence, which was carefully estimated to an accuracy of $5.4(0.5)\times10^{-17}$ using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

physics.atom-ph

Single-qubit measurement of Heisenberg uncertainty lower bounds for three incompatible observables

Being one of the centroidal concepts in quantum theory, the fundamental constraint imposed by Heisenberg uncertainty relations has always been a subject of immense attention and challenging in the context of joint measurements of general quantum mechanical observables. In particular, the recent extension of the original uncertainty relations has grabbed a distinct research focus and set a new ascendent target in quantum mechanics and quantum information processing. In the present work we explore the joint measurements of three incompatible observables, following the basic idea of a newly proposed error trade-off relation. In comparison to the counterpart of two incompatible observables, the joint measurements of three incompatible observables are more complex and of more primal interest in understanding quantum mechanical measurements. Attributed to the pristine idea proposed by Heisenberg in 1927, we develop the error trade-off relations for compatible observables to categorically approximate the three incompatible observables. Implementing these relations we demonstrate the first experimental witness of the joint measurements for three incompatible observables using a single ultracold $^{40}Ca^{+}$ ion in a harmonic potential. We anticipate that our inquisition would be of vital importance for quantum precision measurement and other allied quantum information technologies.

quant-ph

Roles of electron correlation effects for accurate determination of $g_j$ factors of low-lying states of $^{113}$Cd$^+$ and their applications to atomic clock

We investigate roles of electron correlation effects in the determination of $g_j$ factors of the $ns~^2S_{1/2}$ ($n$=5,6,7), $np~^2P_{1/2,3/2}$ ($n$=5,6), $5d~^2D_{3/2,5/2}$, and $4f~^2F_{5/2,7/2}$ states of the singly ionized cadmium (Cd$^+$) ion. Single and double excited configurations along with important valence triple excited configurations through relativistic coupled-cluster (RCC) theory are taken into account for incorporating electron correlation effects in our calculations. We find significant contributions from the triples to the lower $S$ and $P$ states for attaining high accuracy results. The contributions of Breit interaction and lower-order quantum electrodynamics effects, such as vacuum polarization and self-energy corrections, are also estimated using the RCC theory and are quoted explicitly. In addition, we present energies of the aforementioned states from our calculations and compare them with the experimental results to validate $g_j$ values. Using the $g_j$ factor of the ground state, systematical shift due to the Zeeman effect in the microwave clock frequency of the $|5s~^2S_{1/2}, F=0,m_F=0 \rangle \leftrightarrow |5s~^2S_{1/2}, F=1,m_F=0 \rangle$ transition in $^{113}$Cd$^+$ ion has been estimated.

physics.atom-ph

Direct temperature determination of a sympathetically cooled large 113Cd+ ion crystal for a microwave clock

This paper reports the direct temperature determination of sympathetically cooled 113Cd+ ions with laser-cooled 24Mg+ in a linear Paul trap. The sympathetically cooled ion species distribute in the outer shell of the large ensembles, which contain up to 3.3E5 ions. With optimized parameters, the minimum temperature of the sympathetically cooled 113Cd+ ions was measured to be tens of mK. These results indicate promising performance for microwave atomic clocks. The second order Doppler frequency shift is two orders of magnitudes lower and the Dick effect is suppressed.

physics.atom-ph

A tool framework for tweaking features in synthetic datasets

Researchers and developers use benchmarks to compare their algorithms and products. A database benchmark must have a dataset D. To be application-specific, this dataset D should be empirical. However, D may be too small, or too large, for the benchmarking experiments. D must, therefore, be scaled to the desired size. To ensure the scaled D' is similar to D, previous work typically specifies or extracts a fixed set of features F = {F_1, F_2, . . . , F_n} from D, then uses F to generate synthetic data for D'. However, this approach (D -> F -> D') becomes increasingly intractable as F gets larger, so a new solution is necessary. Different from existing approaches, this paper proposes ASPECT to scale D to enforce similarity. ASPECT first uses a size-scaler (S0) to scale D to D'. Then the user selects a set of desired features F'_1, . . . , F'_n. For each desired feature F'_k, there is a tweaking tool T_k that tweaks D' to make sure D' has the required feature F'_k. ASPECT coordinates the tweaking of T_1,...,T_n to D', so T_n(...(T_1(D'))...) has the required features F'_1,...,F'_n. By shifting from D -> F -> D' to D -> D' -> F', data scaling becomes flexible. The user can customise the scaled dataset with their own interested features. Extensive experiments on real datasets show that ASPECT can enforce similarity in the dataset effectively and efficiently.

cs.DB

Suppression of Dick Effect in the Ramsey-CPT atomic clock by Interleaving Lock

For most passive atomic clocks, the Dick effect is one of the main limits to reach its frequency stability limitation due to quantum projection noise. In this paper, we demonstrate that the minimization of the Dick effect for the Ramsey-CPT atomic clock can be accomplished by interleaving lock. By optimizing the duty circle of laser pulses, averaging time during detection and optical intensity of laser beam, the Dick effect induced Allan deviation can be reduced to the level of 10^-14.

physics.ins-det