Searcharxiv⌕ Search

arXiv subjects

Jan Meijer

Publications and source records attributed to Jan Meijer.

44 records · Page 3Linked to original sources

Nanoimplantation and Purcell enhancement of single NV centers in photonic crystal cavities in diamond

We present the controlled creation of single nitrogen-vacancy (NV) centers via ion implantation at the center of a photonic crystal cavity which is fabricated in an ultrapure, single crystal diamond membrane. High-resolution placement of NV centers is achieved using collimation of a 5keV-nitrogen ion beam through a pierced tip of an atomic force microscope (AFM). We demonstrate coupling of the implanted NV centers' broad band fluorescence to a cavity mode and observe Purcell enhancement of the spontaneous emission. The results are in good agreement with a master equation model for the cavity coupling.

quant-ph↗

Detection of a single fundamental charge with nanoscale resolution in ambient conditions using the NV$^-$ center in diamond

Single charge detection with nanoscale spatial resolution in ambient conditions is a current frontier in metrology that has diverse interdisciplinary applications. Here, such single charge detection is demonstrated using two nitrogen-vacancy (NV) centers in diamond. One NV center is employed as a sensitive electrometer to detect the change in electric field created by the displacement of a single electron resulting from the optical switching of the other NV center between its neutral (NV$^0$) and negative (NV$^-$) charge states. As a consequence, our measurements also provide direct insight into the charge dynamics inside the material.

cond-mat.mes-hall↗

High fidelity spin entanglement using optimal control

Precise control of quantum systems is of fundamental importance for quantum device engineering, such as is needed in the fields of quantum information processing, high-resolution spectroscopy and quantum metrology. When scaling up the quantum registers in such devices, several challenges arise: individual addressing of qubits in a dense spectrum while suppressing crosstalk, creation of entanglement between distant nodes, and decoupling from unwanted interactions. The experimental implementation of optimal control is a prerequisite to meeting these challenges. Using engineered microwave pulses, we experimentally demonstrate optimal control of a prototype solid state spin qubit system comprising thirty six energy levels. The spin qubits are associated with proximal nitrogen-vacancy (NV) centers in diamond. We demonstrate precise single-electron spin qubit operations with an unprecedented fidelity F \approx 0.99 in combination with high-efficiency storage of electron spin states in a nuclear spin quantum memory. Matching single-electron spin operations with spin-echo techniques, we further realize high-quality entangled states (F > 0.82) between two electron spins on demand. After exploiting optimal control, the fidelity is mostly limited by the coherence time and imperfect initialization. Errors from crosstalk in a crowded spectrum of 8 lines as well as detrimental effects from active dipolar couplings have been simultaneously eliminated to unprecedented extent. Finally, by entanglement swapping to nuclear spins, nuclear spin entanglement over a length scale of 25 nm is demonstrated. This experiment underlines the importance of optimal control for scalable room temperature spin-based quantum information devices.

quant-ph↗

Statistical investigations on nitrogen-vacancy center creation

Experiments show that shallow nitrogen implantations (<10keV) result in a negatively charged nitrogen-vacancy center (NV-) yield of 0.01-0.1%. The most succesful technique for introducing NV- centers in the carbon matrix is ion implantation followed by annealing at 1100K. We investigated the influence of channeling effects during shallow implantation and statistical diffusion using molecular dynamics (MD) and Monte Carlo (MC) approaches. Energy barriers for the diffusion process were calculated using the density functional theory (DFT). Our simulations show a significant difference in the NV yield compared to the experiment. Statistically, 25% of the implanted nitrogens form a NV center after annealing.

cond-mat.mtrl-sci↗

Maskless and targeted creation of arrays of colour centres in diamond using focused ion beam technology

The creation of nitrogen-vacancy centres in diamond is nowadays well controlled using nitrogen implantation and annealing. Although the high-resolution placement of NV centres has been demonstrated using either collimation through pierced AFM tips or masks with apertures made by electron beam lithography, a targeted implantation into pre-defined structures in diamond may not be achieved using these techniques. We show that a beam of nitrogen ions can be focused to approximately 100 nm using focused ion beam (FIB) technology. The nitrogen ion beam is produced using an electron cyclotron resonance (ECR) plasma source. Combined with a scanning electron microscope, the nitrogen-FIB offers new possibilities for the targeted creation of single defects in diamond. This maskless technology is suitable for example for the creation of optical centres in the cavities of photonic crystals or in diamond tips for scanning magnetometry. Finally, we further show that by changing the gas source from nitrogen to xenon, standard FIB milling capabilities are also available within the same tool.

cond-mat.mes-hall↗

Room temperature entanglement between distant single spins in diamond

Entanglement is the central yet fleeting phenomena of quantum physics. Once being considered a peculiar counter-intuitive property of quantum theory it has developed into the most central element of quantum technology providing speed up to quantum computers, a path towards long distance quantum cryptography and increased sensitivity in quantum metrology. Consequently, there have been a number of experimental demonstration of entanglement between photons, atoms, ions as well as solid state systems like spins or quantum dots, superconducting circuits and macroscopic diamond. Here we experimentally demonstrate entanglement between two engineered single solid state spin quantum bits (qubits) at ambient conditions. Photon emission of defect pairs reveals ground state spin correlation. Entanglement (fidelity = 0.67 \pm 0.04) is proven by quantum state tomography. Moreover, the lifetime of electron spin entanglement is extended to ms by entanglement swapping to nuclear spins, demonstrating nuclear spin entanglement over a length scale of 25 nm. The experiments mark an important step towards a scalable room temperature quantum device being of potential use in quantum information processing as well as metrology.

quant-ph↗

Single photon emitters based on Ni/Si related defects in single crystalline diamond

We present investigations on single Ni/Si related color centers produced via ion implantation into single crystalline type IIa CVD diamond. Testing different ion dose combinations we show that there is an upper limit for both the Ni and the Si dose 10^12/cm^2 and 10^10/cm^2 resp.) due to creation of excess fluorescent background. We demonstrate creation of Ni/Si related centers showing emission in the spectral range between 767nm and 775nm and narrow line-widths of 2nm FWHM at room temperature. Measurements of the intensity auto-correlation functions prove single-photon emission. The investigated color centers can be coarsely divided into two groups: Drawing from photon statistics and the degree of polarization in excitation and emission we find that some color centers behave as two-level, single-dipole systems whereas other centers exhibit three levels and contributions from two orthogonal dipoles. In addition, some color centers feature stable and bright emission with saturation count rates up to 78kcounts/s whereas others show fluctuating count rates and three-level blinking.

cond-mat.mtrl-sci↗

Single-photon emission from Ni-related color centers in CVD diamond

Color centers in diamond are very promising candidates among the possible realizations for practical single-photon sources because of their long-time stable emission at room temperature. The popular nitrogen-vacancy center shows single-photon emission, but within a large, phonon-broadened spectrum (~100nm), which strongly limits its applicability for quantum communication. By contrast, Ni-related centers exhibit narrow emission lines at room temperature. We present investigations on single color centers consisting of Ni and Si created by ion implantation into single crystalline IIa diamond. We use systematic variations of ion doses between 10^8/cm^2 and 10^14/cm^2 and energies between 30keV and 1.8MeV. The Ni-related centers show emission in the near infrared spectral range (~770nm to 787nm) with a small line-width (~3nm FWHM). A measurement of the intensity correlation function proves single-photon emission. Saturation measurements yield a rather high saturation count rate of 77.9 kcounts/s. Polarization dependent measurements indicate the presence of two orthogonal dipoles.

quant-ph↗