SearcharxivSearch

arXiv subjects

Jared Richards

Publications and source records attributed to Jared Richards.

2 recordsLinked to original sources

Beam Test Performance of AstroPix sensor with 120 GeV protons

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor (MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). We present beam test results of the AstroPix v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor's 500 um pixel pitch enabled precise measurement of the beam profile, providing important information for calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles and use them to extract the corresponding effective depletion depth.

physics.ins-det

Evaluation of the Response to Electrons and Pions in the Scintillating Fiber and Lead Calorimeter for the Future Electron-Ion Collider

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests [NIM A 596 (2008) 327-337 and arXiv:1801.03088] to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

physics.ins-det