SearcharxivSearch

arXiv · 2504.03079

Evaluation of the Response to Electrons and Pions in the Scintillating Fiber and Lead Calorimeter for the Future Electron-Ion Collider

Abstract

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests [NIM A 596 (2008) 327-337 and arXiv:1801.03088] to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

Explore related subjects

Keep this discovery

BibTeXRIS

Henry Klest, Maria Żurek, Tegan D. Beattie, Manoj Jadhav, Sylvester Joosten, Maggie Kerr, Bobae Kim, Minho Kim, Jessica Metcalfe, Zisis Papandreou, Jared Richards, Jonathan Zarling. 2025-04-03. Evaluation of the Response to Electrons and Pions in the Scintillating Fiber and Lead Calorimeter for the Future Electron-Ion Collider. https://doi.org/10.1088/1748-0221/20/07/p07028

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det