SearcharxivSearch

arXiv subjects

Javier Balibrea-Correa

Publications and source records attributed to Javier Balibrea-Correa.

8 recordsLinked to original sources

Direct Experiments of Neutron Capture on Stable and Unstable Isotopes for Stellar Nucleosynthesis Studies

Neutron-capture reactions provide essential nuclear-physics input for modeling the synthesis of heavy elements in stars. The growing precision of stellar spectroscopy and isotopic measurements in presolar SiC grains now demands cross sections with improved accuracy over the full energy range, and access to unstable nuclei relevant to slow (s-) process branchings and the intermediate (i-) process. This article reviews recent progress in direct neutron-capture measurements, focusing on time-of-flight (TOF) experiments at CERN n_TOF and complementary activation techniques. Substantial advances have been achieved for stable s-only and bottleneck isotopes, significantly improving constraints on s-process models. In parallel, the combination of high instantaneous neutron fluxes and advanced detector systems has facilitated first-time measurements of several radioactive branching-point nuclei. Feasibility studies, however, reveal current limitations related to sample availability, background conditions, and restricted energy coverage. In this context, the complementarity between TOF and activation emerges as a central strategy. Future developments, including high-flux facilities and novel inverse-kinematics experiments in ion storage rings, are expected to extend the boundaries of neutron-capture measurements, overcoming current limitation

nucl-ex

Hybrid Compton-PET Imaging for ion-range verification:A Preclinical Study for Proton-, Helium-, and Carbon-Therapy at HIT

Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and researched methodologies, both of them with their own advantages and challenges. Thus far, both of them have been explored for ion-range verification in an independent way. However, the simultaneous combination of PET and PGI within the same imaging framework may open-up the possibility to exploit more efficiently all radiative emissions excited in the tissue by the ion beam. Here we report on the first pre-clinical implementation of an hybrid PET-PGI imaging system, hereby exploring its performance over several ion-beam species (H, He and C), energies (55 MeV to 275 MeV) and intensities (10$^7$-10$^9$ ions/spot), which are representative of clinical conditions. The measurements were carried out using the pencil-beam scanning technique at the synchrotron accelerator of the Heavy Ion Therapy centre in Heidelberg utilizing an array of four Compton cameras in a twofold front-to-front configuration. The results demonstrate that the hybrid PET-PGI technique can be well suited for relatively low energies (55-155 MeV) and beams of protons. On the other hand, for heavier beams of helium and carbon ions at higher energies (155-275 MeV), range monitoring becomes more challenging owing to large backgrounds from additional nuclear processes. The experimental results are well understood on the basis of realistic Monte Carlo (MC) calculations, which show a satisfactory agreement with the measured data. This work can guide further upgrades of the hybrid PET-PGI system towards a clinical implementation of this innovative technique.

physics.med-ph

First experimental results and optimization study of the portable neutron-gamma imager GN-Vision

GN-Vision is a compact, dual-modality imaging device designed to simultaneously localize the spatial origin of $γ$-ray and slow neutron sources, with potential applications in nuclear safety, security, and hadron therapy. The system utilizes two position-sensitive detection planes, combining Compton imaging techniques for $γ$-ray visualization with passive collimation for imaging slow and thermal neutrons (energies below 100 eV). This paper presents the first experimental outcomes from the initial GN-Vision prototype, focused on the development of its neutron imaging capabilities. Following this experimental assessment, we explore the device$'$s performance potential and discuss several Monte Carlo simulation-based optimizations aimed at refining the neutron collimation system. These optimizations seek to improve real-time imaging efficiency and cost-effectiveness, enhancing GN-Vision$'$s applicability for future practical deployments.

physics.ins-det

A computer-vision aided Compton-imaging system for radioactive waste characterization and decommissioning of nuclear power plants

Nuclear energy production is inherently tied to the management and disposal of radioactive waste. Enhancing classification and monitoring tools is therefore crucial, with significant socioeconomic implications. This paper reports on the applicability and performance of a high-efficiency, cost-effective and portable Compton camera for detecting and visualizing low- and medium-level radioactive waste from the decommissioning and regular operation of nuclear power plants. The results demonstrate the good performance of Compton imaging for this type of application, both in terms of image resolution and reduced measuring time. A technical readiness level of TRL7 has been thus achieved with this system prototype, as demonstrated with dedicated field measurements carried out at the radioactive-waste disposal plant of El Cabril (Spain) utilizing a pluarility of radioactive-waste drums from decomissioned nuclear power plants. The performance of the system has been enhanced by means of computer-vision techniques in combination with advanced Compton-image reconstruction algorithms based on Maximum-Likelihood Expectation Maximization. Finally, we also show the feasibility of 3D tomographic reconstruction from a series of relatively short measurements around the objects of interest. The potential of this imaging system to enhance nuclear waste management makes it a promising innovation for the nuclear industry.

physics.ins-det

Towards Real Time Compton Imaging in Demanding Conditions

Compton cameras are radiation detectors that provide spatial information on the origin of the γ-ray sources based on the Compton scattering effect. Many applications require these detectors to be used at high counting rate. As such, the preprocessing of the detections as well as the imaging algorithms are required to be time-efficient in order for the data to be processed in real time. In this work, optimizations to the preprocessing of events in Compton cameras based on monolithic crystals, with special focus on event identification, were implemented using a parallelizable algorithm. Regarding imaging, an established 3D back projection algorithm was parallelized and implemented using SYCL. The parallel implementation of the algorithm was included without and with several optimizations such as the pre-computing values, discarding low impact contributions based on angle, and selecting an efficient shape of the image universe. The implementations were tested with Intel CPUs, GPUs, and NVIDIA GPUs. An outlook into the study of algorithms to reconstruct the position of interaction within Compton cameras based on monolithic crystals into segmented regions and other next steps is included.

physics.ins-det

The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy

This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in nuclear astrophysics experiments at CERN, is being optimized for detecting and imaging 478 keV gamma-rays, critical for accurate BNCT dosimetry. Detailed Monte Carlo simulations were used to optimize the i-TED detector configuration and enhance its performance in the challenging radiation environment typical of BNCT. Additionally, advanced 3D image reconstruction algorithms, including a combination of back-projection and List-Mode Maximum Likelihood Expectation Maximization (LM-MLEM), are implemented and validated through simulations. Preliminary experimental tests at the Institut Laue-Langevin (ILL) demonstrate the potential of i-TED in a clinical setting, with ongoing experiments focusing on improving imaging capabilities in realistic BNCT conditions.

physics.med-ph

Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification

We report on an hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA cyclotron facility using a set of two synchronous Compton imagers and different target materials. The time structure of the 18~MeV proton beam was shaped with a series of beam-on and beam-off intervals, thereby mimicking a pulsed proton beam on a long time scale. During beam-on intervals, Compton imaging was performed utilizing the high energy $γ$-rays promptly emitted from the nuclear reactions occurring in the targets. In the course of the beam-off intervals in-situ positron-emission tomography was accomplished with the same imagers using the $β^{+}$ decay of activated nuclei. The targets used were stacks of different materials covering also various proton ranges and energies. A systematic study on the performance of these two complementary imaging techniques is reported and the experimental results interpreted on the basis of Monte Carlo calculations. The results demonstrate the possibility to combine both imaging techniques in a concomitant way, where high-efficiency prompt-gamma imaging is complemented with the high spatial accuracy of PET. Empowered by these results we suggest that a pulsed beam with a suitable duty cycle, in conjunction with in-situ Compton- and PET-imaging may help to attain complementary information and quasi real-time range monitoring with high accuracy.

physics.med-ph

Towards machine learning aided real-time range imaging in proton therapy

In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been designed for neutron-capture nuclear physics experiments, which are characterized by $γ$-ray energies spanning up to 5-6 MeV, rather low $γ$-ray emission yields and intense neutron induced $γ$-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high $γ$-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl$_{3}$ crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr$_{3}$. Its high time-resolution (CRT$\sim$500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED module features two detection planes of very large LaCl$_{3}$ monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1MeV $γ$-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10$^{8}$ protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy $γ$-rays is compensated by means of Machine-Learning algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.

physics.med-ph