SearcharxivSearch

arXiv subjects

Jessica Steinlechner

Publications and source records attributed to Jessica Steinlechner.

14 recordsLinked to original sources

Thermal Noise Reduction in Ternary Optical Coatings: From Ti::GeO$_2$-Based Ternary Systems to High Index Materials

Minimizing coating thermal noise is crucial for enhancing gravitational wave detector sensitivity, with a target Amplitude Spectral Density Reduction Factor (ASD RF) of $0.5$ relative to standard coatings. This study investigates the design of low-noise dielectric stacks using the 'Double Stack of Doublet' strategy, explored via ad-hoc optimization heuristics specifically developed for efficient parametric analysis of coating performance. We analyze the performance limits of ternary coatings based on SiO$_2$, Ti::SiO$_2$, and Ti::GeO$_2$, considering material property uncertainties and absorption constraints. Optimization results show that this system, even with relaxed absorbance constraint (1 ppm), falls short of the target, achieving a best ASD RF of $\sim 0.69$. Consequently, we explore alternative ternary 'Double Stack of Doublet' designs incorporating higher-refractive-index materials. Simulations demonstrate that incorporating alternative high-index materials offers a promising pathway, potentially enabling the achievement of the project target. We discuss the optimization strategies, performance trade-offs, design robustness, and implications of using high-index, potentially higher-loss materials for next-generation optical coatings.

physics.optics

Mechanical Characterisation of Silicon for the ETpathfinder Test Masses

The next generation of gravitational-wave detectors, such as the Einstein Telescope, is designed to reduce noise in a wide band of frequencies compared to the current generation, through the use of new technologies. ETpathfinder, designed as an R&D facility for these technologies, is a prototype for which the mirrors were chosen to be made of crystalline silicon, produced by the Leibniz-Institut f\"ur Kristallz\"uchtung. This material choice was made to pave the way for a low thermal noise level at cryogenic temperatures in the Einstein Telescope. This paper shows the mechanical loss of silicon designated to become the test masses for ETpathfinder in the range between room temperature and 53K. In addition, the effect of the anisotropic nature of silicon on the measurement procedure is addressed. Predictions are made of the contribution of the mirror substrate material to the overall ETpathfinder noise budget.

physics.ins-det

Challenges and Opportunities of Gravitational Wave Searches above 10 kHz

The first direct measurement of gravitational waves by the LIGO and Virgo collaborations has opened up new avenues to explore our Universe. This white paper outlines the challenges and gains expected in gravitational-wave searches at frequencies above the LIGO/Virgo band. The scarcity of possible astrophysical sources in most of this frequency range provides a unique opportunity to discover physics beyond the Standard Model operating both in the early and late Universe, and we highlight some of the most promising of these sources. We review several detector concepts that have been proposed to take up this challenge, and compare their expected sensitivity with the signal strength predicted in various models. This report is the summary of a series of workshops on the topic of high-frequency gravitational wave detection, held in 2019 (ICTP, Trieste, Italy), 2021 (online) and 2023 (CERN, Geneva, Switzerland).

gr-qc

Comparison of arm cavity optical losses for the two wavelengths of the Einstein Telescope gravitational wave detector

A new generation of gravitational wave detectors is currently being designed with the likely use of a different laser wavelength compared to current instruments. The estimation of the optical losses for this new wavelength is particularly relevant to derive the detector sensitivity and also to anticipate the optical performances of future instruments. In this article, we measured the absorption and angle-resolved scattering of several mirror samples in order to compare optical losses at a wavelength of 1064 and 1550\ nm. In addition, we have carried out simulations of the Einstein Telescope arm cavities at 1064 and 1550\ nm taking into account losses due to surface low-spatial frequency flatness. Our results suggest that optical losses as measured at 1064\ nm are about twice as large as those at 1550\ nm as predicted with a simple model.

physics.optics

Science with the Einstein Telescope: a comparison of different designs

The Einstein Telescope (ET), the European project for a third-generation gravitational-wave detector, has a reference configuration based on a triangular shape consisting of three nested detectors with 10 km arms, where in each arm there is a `xylophone' configuration made of an interferometer tuned toward high frequencies, and an interferometer tuned toward low frequencies and working at cryogenic temperature. Here, we examine the scientific perspectives under possible variations of this reference design. We perform a detailed evaluation of the science case for a single triangular geometry observatory, and we compare it with the results obtained for a network of two L-shaped detectors (either parallel or misaligned) located in Europe, considering different choices of arm-length for both the triangle and the 2L geometries. We also study how the science output changes in the absence of the low-frequency instrument, both for the triangle and the 2L configurations. We examine a broad class of simple `metrics' that quantify the science output, related to compact binary coalescences, multi-messenger astronomy and stochastic backgrounds, and we then examine the impact of different detector designs on a more specific set of scientific objectives.

gr-qc

A Cryogenic Silicon Interferometer for Gravitational-wave Detection

The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.

astro-ph.IM

Birefringence Measurements on Crystalline Silicon

Crystalline silicon has been proposed as a new test mass material in third generation gravitational wave detectors such as the Einstein Telescope (ET). Birefringence can reduce the interferometric contrast and can produce dynamical disturbances in interferometers. In this work we use the method of polarisation-dependent resonance frequency analysis of Fabry-Perot-cavities containing silicon as a birefringent medium. Our measurements show a birefringence of silicon along the (111) axis of the order of $Δ\, n \approx 10^{-7}$ at a laser wavelength of 1550nm and room temperature. A model is presented that explains the results of different settings of our measurements as a superposition of elastic strains caused by external stresses in the sample and plastic strains possibly generated during the production process. An application of our theory on the proposed ET test mass geometry suggests no critical effect on birefringence due to elastic strains.

physics.optics

Thermal Noise Reduction and Absorption Optimisation via Multi-Material Coatings

Future gravitational wave detectors (GWDs) such as Advanced LIGO upgrades and the Einstein Telescope are planned to operate at cryogenic temperatures using crystalline silicon (cSi) test-mass mirrors at an operation wavelength of 1550 nm. The reduction in temperature in principle provides a direct reduction in coating thermal noise, but the presently used coating stacks which are composed of silica (SiO2) and tantala (Ta2O5) show cryogenic loss peaks which results in less thermal noise improvement than might be expected. Due to low mechanical loss at low temperature amorphous silicon (aSi) is a very promising candidate material for dielectric mirror coatings and could replace Ta2O5. Unfortunately, such a aSi/SiO2 coating is not suitable for use in GWDs due to high optical absorption in aSi coatings. We explore the use of a three material based coating stack. In this multi-material design the low absorbing Ta2O5 in the outermost coating layers significantly reduces the incident light power, while aSi is used only in the lower bilayers to maintain low optical absorption. Such a coating design would enable a reduction of Brownian thermal noise by 25%. We show experimentally that an optical absorption of only (5.3 +/- 0.4)ppm at 1550 nm should be achievable.

physics.optics

Mapping the Optical Absorption of a Substrate-Transferred Crystalline AlGaAs Coating at 1.5um

The sensitivity of 2nd and 3rd generations of interferometric gravitational wave detectors will be limited by thermal noise of the test-mass mirrors and highly reflective coatings. Recently developed crystalline coatings show a promising thermal noise reduction compared to presently used amorphous coatings. However, stringent requirements apply to the optical properties of the coatings as well. We have mapped the optical absorption of a crystalline AlGaAs coating which is optimized for high reflectivity for a wavelength of 1064nm. The absorption was measured at 1550nm where the coating stack transmits approximately 70% of the laser light. The measured absorption was lower than (30.2 +/- 11.1)ppm which is equivalent to (3.6 +/- 1.3)ppm for a coating stack that is highly reflective at 1530nm. While this is a very promising low absorption result for alternative low--loss coating materials, further work will be necessary to reach the requirements of <1ppm for future gravitational wave detectors.

physics.optics

Optical Absorption Measurement at 1550 nm on a Highly-Reflective Si/SiO$_2$ Coating Stack

Future laser-interferometric gravitational wave detectors (GWDs) will potentially employ test mass mirrors from crystalline silicon and a laser wavelength of $1550\,\rm{nm}$, which corresponds to a photon energy below the silicon bandgap. Silicon might also be an attractive high-refractive index material for the dielectric mirror coatings. Films of amorphous silicon (a-Si), however, have been found to be significantly more absorptive at $1550\,\rm{nm}$ than crystalline silicon (c-Si). Here, we investigate the optical absorption of a Si/SiO$_2$ dielectric coating produced with the ion plating technique. The ion plating technique is distinct from the standard state-of-the-art ion beam sputtering technique since it uses a higher processing temperature of about 250$^\circ$C, higher particle energies, and generally results in higher refractive indices of the deposited films. Our coating stack was fabricated for a reflectivity of $R=99.95\,\%$ for s-polarized light at $1550\,\rm{nm}$ and for an angle of incidence of 44$^\circ$. We used the photothermal self-phase modulation technique to measure the coating absorption in s-polarization and p-polarization. We obtained $α^{\rm coat}_{s}=(1035 \pm 42)\,\rm{ppm}$ and $α^{\rm coat}_{p}=(1428 \pm 97)\,\rm{ppm}$. These results correspond to an absorption coefficient which is lower than literature values for a-Si which vary from $100\,\rm{/cm}$ up to $2000\,\rm{/cm}$. It is, however, still orders of magnitude higher than expected for c-Si and thus still too high for GWD applications.

physics.optics

Indication for dominating surface absorption in crystalline silicon test masses at 1550nm

The sensitivity of future gravitational wave (GW) observatories will be limited by thermal noise in a wide frequency band. To reduce thermal noise, the European GW observatory Einstein GW Telescope (ET) is suggested to use crystalline silicon test masses at cryogenic temperature and a laser wavelength of 1550nm. Here, we report a measurement of the optical loss in a prototype high-resistivity crystalline silicon test mass as a function of optical intensity at room temperature. The total loss from both the bulk crystal and the surfaces was determined in a joint measurement. The characterization window ranged from small intensities below 1W/cm^2, as planned to be used in ET, up to 21kW/cm^2. A non-linear absorption was observed for intensities above a few kW/cm^2. In addition we have observed an intensity-independent offset that possibly arises from absorption in the crystal surfaces. This absorption was estimated to approx. 800 ppm/surface, which might be too high for a cryogenic operation of a fibre-suspended silicon test mass. Such an offset was not observed in other recent measurements that were insensitive to surface absorption. Finally, a set of further characterization measurements is proposed to clearly separate the contributions from the surfaces and the bulk crystal.

physics.optics

Optical Absorption Measurements on Crystalline Silicon at 1550nm

Crystalline silicon is currently being discussed as test-mass material for future generations of gravitational wave detectors that will operate at cryogenic temperatures. We present optical absorption measurements on a large-dimension sample of crystalline silicon at a wavelength of 1550nm at room temperature. The absorption was measured in a monolithic cavity setup using the photo-thermal self-phase modulation technique. The result for the absorption coefficient of this float-zone sample with a specific resistivity of 11kOhm cm was measured to be α_A=(264 +/- 39)ppm/cm.

physics.optics

High-efficiency frequency doubling of continuous-wave laser light

We report on the observation of high efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of (95 \pm 1)%. The latter value is based on the measured depletion of the fundamental field being consistent with the absolute values derived from numerical simulations. According to our model, the conversion efficiency achieved was limited by the non-perfect mode-matching into the nonlinear cavity and the pump power available. Our result shows that cavity-assisted frequency conversion based on PPKTP is well suited for low-decoherence frequency conversion of quantum states of light.

quant-ph

Measuring small absorptions exploiting photo-thermal self-phase modulation

We present a method for the measurement of small optical absorption coefficients. The method exploits the deformation of cavity Airy peaks that occur if the cavity contains an absorbing material with a non-zero thermo-refractive coefficient dn/dT or a non-zero expansion coefficient ath . Light absorption leads to a local temperature change and to an intensity-dependent phase shift, i.e. to a photo-thermal self-phase modulation. The absorption coefficient is derived from a comparison of time-resolved measurements with a numerical time-domain simulation applying a Markov-chain Monte-Carlo (MCMC) algorithm. We apply our method to the absorption coefficient of lithium niobate (LN) doped with 7mol% magnesium oxide (MgO) and derive a value of alphaLN = (5.9 +/- 0.9) *10^-4/cm . Our method should also apply to materials with much lower absorption coefficients. Based on our modelling we estimate that with cavity finesse values of the order 10^4, absorption coefficients of as low as 10^-8 /cm can be measured.

physics.optics