SearcharxivSearch

arXiv subjects

Jiatong Yang

Publications and source records attributed to Jiatong Yang.

4 recordsLinked to original sources

Distinguishing types of correlated errors in superconducting qubits

Errors in superconducting qubits that are correlated in time and space can pose problems for quantum error correction codes. Radiation from cosmic and terrestrial sources can increase the quasiparticle (QP) density in a superconducting qubit device, resulting in an increased rate of QPs tunneling across proximal Josephson junctions (JJs) and causing correlated errors. Mechanical vibrations, such as those induced by the pulse tube (PT) in a dry dilution refrigerator, are also a known source of correlated errors. We measure two types of errors in the same device, linking the first to ionizing radiation and the second to PT operation. We present a method for distinguishing these two types of errors by their temporal, spatial, and frequency domain features, enabling physically motivated error-mitigation strategies. We also present accelerometer data to study the correlation between PT-induced vibrations and the errors. We measure arrays of transmon qubits where the difference in superconducting gap across the JJ is less than the qubit energy, as well as those where the gap is greater than the qubit energy, which has been shown to mitigate radiation-induced errors. The rate of both types of errors is reduced in these latter devices, suggesting that gap engineering is also protective against PT-induced errors.

quant-ph

Characterization of Aluminum Microwave SQUID Multiplexers for CE$ν$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($μ$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $μΦ_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $μΦ_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $μ$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $μΦ_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $μ$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

Characterization of Radiation-Induced Errors in Superconducting Qubits Protected with Various Gap-Engineering Strategies

Impacts from high-energy particles cause correlated errors in superconducting qubits by increasing the quasiparticle density in the vicinity of the Josephson junctions (JJs). Such errors are particularly harmful as they cannot be easily remedied via conventional error correcting codes. Recent experiments reduced correlated errors by making the difference in superconducting gap energy across the JJ larger than the qubit transition energy. In this work, we assess gap engineering near the JJ ($δΔ_{\mathrm{JJ}}$) and the capacitor/ground-plane ($δΔ_{\mathrm{M1}}$) by exposing arrays of transmon qubits to two sources of radiation. For $α$-particles from an $^{241}$Am source, we observe $T_1$ errors correlated in space and time, supporting a hypothesis that hadronic cosmic rays are a major contributor to the $10^{-10}$ error floor observed in Ref. 1. For electrons from a pulsed linear accelerator, we observe temporally correlated $T_1$ and $T_2$ errors, this measurement is insensitive to spatial correlations. We observe that the severity of correlated $T_1$ errors is reduced for qubit arrays with a greater degree of gap engineering at the JJ. For both $T_1$ and $T_2$ errors, the recovery time is hastened by an increased $δΔ_{\mathrm{M1}}$, which we attribute to the trapping of quasiparticles into the capacitor/ground-plane. We construct a model of quasiparticle dynamics that qualitatively agrees with our observations. This work reinforces the multifaceted influence of radiation on superconducting qubits and provides strategies for improving radiation resilience.

quant-ph

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex