Searcharxiv⌕ Search

arXiv subjects

Johann Cohen Tanugi

Publications and source records attributed to Johann Cohen Tanugi.

3 recordsLinked to original sources

The Vera C. Rubin Observatory Data Preview 1

We present Rubin Data Preview 1 DP1, the first data from the NSF DOE Vera C Rubin Observatory, comprising raw and calibrated single epoch images, coadds, difference images, detection catalogs, and ancillary data products. DP1 is based on 1792 optical near infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera LSSTComCam on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón Chile in late 2024. DP1 covers $\sim$15 deg$^2$ distributed across seven roughly equal-sized non-contiguous fields, each independently observed in six broad photometric bands $ugrizy$. The median FWHM of the point spread function across all bands is approximately 1.14 arcseconds, with the sharpest images reaching about 0.58 arcseconds. The 5$σ$ point source depths for coadded images in the deepest field the Extended Chandra Deep Field South are $u$ = 24.55, $g$ = 26.18, $r$ = 25.96, $i$ = 25.71, $z$ = 25.07, $y$ = 23.1. Other fields are no more than 2.2 magnitudes shallower in any band where they have nonzero coverage. DP1 contains approximately 2.3 million distinct astrophysical objects, of which 1.6 million are extended in at least one band in coadds and 431 solar system objects of which 93 are new discoveries. DP1 is approximately 3.5 TB in size and is available to Rubin data rights holders via the Rubin Science Platform a cloud based environment for the analysis of petascale astronomical data. While small compared to future LSST releases its high quality and diversity of data support a broad range of early science investigations ahead of full operations in 2026.

astro-ph.IM↗

StarDICE III: Characterization of the photometric instrument with a Collimated Beam Projector

The measurement of type Ia supernovae magnitudes provides cosmological distances, which can be used to constrain dark energy parameters. Large photometric surveys require a substantial improvement in the calibration precision of their photometry to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment is designed to establish accurate broadband flux references for these surveys, aiming for sub-percent precision in magnitude measurements. This requires a precise measurement of the filter bandpasses of both the StarDICE and survey instruments with sub-nanometer accuracy. To that end, we have developed the Collimated Beam Projector (CBP), an optical device capable of calibrating the throughput of an astronomical telescope and of its filters. The CBP is built from a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam that is continuously monitored in flux and wavelength. The CBP output light flux is measured using a large area photodiode, previously calibrated relative to a NIST photodiode. We derive the StarDICE telescope throughput and filter transmissions from the CBP measurements, anchoring it to the absolute calibration provided by the NIST. After analyzing the systematic uncertainties, we achieved sub-nanometer accuracy in determining filter central wavelengths, measured each filter transmission with a precision of 0.5% per 1nm bin, and detected out-of-band leakages at 0.01%. Furthermore, we have synthesized the equivalent transmission for full pupil illumination from four sample positions in the StarDICE telescope mirror, with an accuracy of approximately 0.2nm for central wavelengths and 7mmag for broadband fluxes. We demonstrated our ability to characterize a telescope throughput down to the mmag, and paved the way for future developments, such as a portable CBP version for in-situ transmission monitoring.

astro-ph.IM↗

StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor

The Hubble diagram of type-Ia supernovae (SNe-Ia) provides cosmological constraints on the nature of dark energy with an accuracy limited by the flux calibration of currently available spectrophotometric standards. The StarDICE experiment aims at establishing a 5-stage metrology chain from NIST photodiodes to stars, with a targeted accuracy of \SI{1}{mmag} in $griz$ colors. We present the first two stages, resulting in the calibration transfer from NIST photodiodes to a demonstration \SI{150}{Mpixel} CMOS sensor (Sony IMX411ALR as implemented in the QHY411M camera by QHYCCD). As a side-product, we provide full characterization of this camera. A fully automated spectrophotometric bench is built to perform the calibration transfer. The sensor readout electronics is studied using thousands of flat-field images from which we derive stability, high resolution photon transfer curves and estimates of the individual pixel gain. The sensor quantum efficiency is then measured relative to a NIST-calibrated photodiode. Flat-field scans at 16 different wavelengths are used to build maps of the sensor response. We demonstrate statistical uncertainty on quantum efficiency below \SI{0.001}{e^-/γ} between \SI{387}{nm} and \SI{950}{nm}. Systematic uncertainties in the bench optics are controlled at the level of \SI{1e-3}{e^-/γ}. Uncertainty in the overall normalization of the QE curve is 1\%. Regarding the camera we demonstrate stability in steady state conditions at the level of \SI{32.5}{ppm}. Homogeneity in the response is below \SI{1}{\percent} RMS across the entire sensor area. Quantum efficiency stays above \SI{50}{\percent} in most of the visible range, peaking well above \SI{80}{\percent} between \SI{440}{nm} and \SI{570}{nm}. Differential non-linearities at the level of \SI{1}{\percent} are detected. A simple 2-parameter model is proposed to mitigate the effect.

astro-ph.IM↗