SearcharxivSearch

arXiv subjects

Juan Pedro Ochoa-Ricoux

Publications and source records attributed to Juan Pedro Ochoa-Ricoux.

10 recordsLinked to original sources

Biases in the Determination of Correlations Between Underground Muon Flux and Atmospheric Temperature

The underground rates of cosmic-ray muons exhibit seasonal variations correlated with effective atmospheric temperature, quantified via a single coefficient. We compare two analysis methods for studying the correlation: the standard Unbinned Method, where all rate-temperature data points are fit simultaneously via linear regression, and the Binned Method, where data points with similar temperatures are first grouped into bins before fitting. We find that while both methods are unbiased in the limit of negligible temperature uncertainties, the Binned Method develops significant bias when temperature uncertainties are present, due to binning-induced distortions. In contrast, the Unbinned Method remains robust if the uncertainties are accurately known. To address the widely encountered issue of imprecise uncertainty estimation, we propose a novel procedure that assesses correlation stability by varying the time intervals and their assigned uncertainties. This approach resolves methodological tensions in studies of seasonal modulation of the muon rate and provides a practical framework for robust correlation estimation under real-world conditions.

hep-ex

Embedded underwater front-end electronics for the 3-inch photomultipliers in the JUNO experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20-kton liquid scintillator-based, low-radioactivity, multi-purpose neutrino detector located 693 meters (1800 m.w.e.) underground in the Guangdong province, China. To detect scintillation light produced in the target, the detector is equipped with 17,612 20-inch photomultipliers (PMTs), forming the Large PMT system (LPMT). In addition, 25,600 3-inch photomultipliers (the Small Photomultiplier System or SPMT) are deployed in the gaps between the LPMTs. This paper presents the design and performance of the underwater front-end electronics developed for the SPMT system. It details the individual electronics boards and their key components, the inter-board interfaces, the system-level design, and the firmware architecture that supports data acquisition and control. It also outlines mechanical and thermal integration, board validation procedures, and system performance metrics. The readout chain includes digitization of 128 PMT channels per unit, synchronized time-stamping, charge measurement, event packaging, and bandwidth management. Comprehensive validation confirms the system's readiness to meet JUNO's stringent physics goals. The underwater electronics achieve noise levels as low as 0.04 photoelectrons with minimal crosstalk (below 0.4%) and a bandwidth of 57 MB/s, ensuring reliable single photo-electron detection and operation under high-rate conditions. The SPMT system has now been fully integrated and installed in JUNO. Its commissioning and physics performance will be reported in a future publication.

physics.ins-det

The High Voltage Splitter board for the JUNO SPMT system

The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control.

physics.ins-det

Multi-Calorimetry in Light-based Neutrino Detectors

Neutrino detectors are among the largest photon detection instruments, built to capture scarce photons upon energy deposition. Many discoveries in neutrino physics, including the neutrino itself, are inseparable from the advances in photon detection technology, particularly in photo-sensors and readout electronics, to yield ever higher precision and richer detection information. The measurement of the energy of neutrinos, referred to as calorimetry, can be achieved in two distinct approaches: photon-counting, where single-photon can be counted digitally, and photon-integration, where multi-photons are aggregated and estimated via analogue signals. The energy is pursued today to reach permille level systematics control precision in ever-vast volumes, exemplified by experiments like JUNO. The unprecedented precision brings to the foreground the systematics due to calorimetric response entanglements in energy, position and time that were negligible in the past, thus driving further innovation in calorimetry. This publication describes a novel articulation that detectors can be endowed with multiple photon detection systems. This multi-calorimetry approach opens the notion of dual-calorimetry detector, consisting of both photon-counting and photon-integration systems, as a cost-effective evolution from the single calorimetry setups used over several decades for most experiments so far. The dual-calorimetry design exploits unique response synergies between photon-counting and photon-integration systems, including correlations and cancellations in calorimetric responses, to maximise the mitigation of response entanglements, thereby yielding permille-level high-precision calorimetry.

hep-ex

Snowmass Neutrino Frontier Report

This report summarizes the current status of neutrino physics and the broad and exciting future prospects identified for the Neutrino Frontier as part of the 2021 Snowmass Process.

hep-ex

Calibration Strategy of the JUNO-TAO Experiment

The Taishan Antineutrino Observatory (JUNO-TAO, or TAO) is a satellite detector for the Jiangmen Underground Neutrino Observatory (JUNO). Located near the Taishan reactor, TAO independently measures the reactor's antineutrino energy spectrum with unprecedented energy resolution. To achieve this goal, energy response must be well calibrated. Using the Automated Calibration Unit (ACU) and the Cable Loop System (CLS) of TAO, multiple radioactive sources are deployed to various positions in the detector to perform a precise calibration of energy response. The non-linear energy response can be controlled within 0.6% with different energy points of these radioactive sources. It can be further improved by using $^{12}\rm B$ decay signals produced by cosmic muons. Through the energy non-uniformity calibration, residual non-uniformity is less than 0.2%. The energy resolution degradation and energy bias caused by the residual non-uniformity can be controlled within 0.05% and 0.3%, respectively. In addition, the stability of other detector parameters, such as the gain of each silicon photo-multiplier, can be monitored with a special ultraviolet LED calibration system.

physics.ins-det

Synergies and Prospects for Early Resolution of the Neutrino Mass Ordering

The measurement of neutrino Mass Ordering (MO) is a fundamental element for the understanding of leptonic flavour sector of the Standard Model of Particle Physics. Its determination relies on the precise measurement of $Δm^2_{31}$ and $Δm^2_{32}$ using either neutrino vacuum oscillations, such as the ones studied by medium baseline reactor experiments, or matter effect modified oscillations such as those manifesting in long-baseline neutrino beams (LB$ν$B) or atmospheric neutrino experiments. Despite existing MO indication today, a fully resolved MO measurement ($\geq$5$σ$) is most likely to await for the next generation of neutrino experiments: JUNO, whose stand-alone sensitivity is $\sim$3$σ$, or LB$ν$B experiments (DUNE and Hyper-Kamiokande). Upcoming atmospheric neutrino experiments are also expected to provide precious information. In this work, we study the possible context for the earliest full MO resolution. A firm resolution is possible even before 2028, exploiting mainly vacuum oscillation, upon the combination of JUNO and the current generation of LB$ν$B experiments (NOvA and T2K). This opportunity is possible thanks to a powerful synergy boosting the overall sensitivity where the sub-percent precision of $Δm^2_{32}$ by LB$ν$B experiments is found to be the leading order term for the MO earliest discovery. We also found that the comparison between matter and vacuum driven oscillation results enables unique discovery potential for physics beyond the Standard Model.

hep-ph

Nuclear Data to Reduce Uncertainties in Reactor Antineutrino Measurements: Summary Report of the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM)

The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coherent elastic neutrino nucleus scattering; although, inverse beta decay is the only demonstrated method so far. Reactor monitoring takes advantage of the differences in the antineutrino yield and spectra resulting from uranium and plutonium fission providing an opportunity to estimate the fissile material composition in the reactor. Recent experiments reveal a deviation between the measured and calculated antineutrino flux and spectra indicating either the existence of yet undiscovered neutrino physics, uncertainties in the reactor source term calculation, incorrect nuclear data, or a combination of all three. To address the nuclear data that impact the antineutrino spectrum calculations and measurements, an international group of over 180 experts in antineutrino physics, reactor analysis, detector development, and nuclear data came together during the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM) to discuss nuclear data needs and achieve concordance on a set of recommended priorities for nuclear data improvements. Three topical sessions provided a forum to gain consensus amongst the participants on the most important data improvements to address two goals: 1) understand the reactor anomaly and 2) improve the ability to monitor reactors using antineutrinos. This report summarizes the outcomes of the workshop discussions and the recommendations for nuclear data efforts that reduce reactor antineutrino measurement uncertainties.

nucl-ex

Mass production and characterization of 3-inch PMTs for the JUNO experiment

26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.

physics.ins-det

Waterproofed Photomultiplier Tube Assemblies for the Daya Bay Reactor Neutrino Experiment

In the Daya Bay Reactor Neutrino Experiment 960 20-cm-diameter waterproof photomultiplier tubes are used to instrument three water pools as Cherenkov detectors for detecting cosmic-ray muons. Of these 960 photomultiplier tubes, 341 are recycled from the MACRO experiment. A systematic program was undertaken to refurbish them as waterproof assemblies. In the context of passing the water leakage check, a success rate better than 97% was achieved. Details of the design, fabrication, testing, operation, and performance of these waterproofed photomultiplier-tube assemblies are presented.

physics.ins-det