Searcharxiv⌕ Search

arXiv subjects

Juha Ala-Laurinaho

Publications and source records attributed to Juha Ala-Laurinaho.

9 recordsLinked to original sources

Fully Scalable Polarization-Reconfigurable S/X-Band Shared-Aperture Phased Array for Ultra-Low Axial-Ratio Scanning

This paper presents a modular S-/X-band shared-aperture phased-array antenna (SAPAA) for satellite-communication ground-station reception. The proposed architecture uses a repeatable unit cell that supports independent S- and X-band operation within the same physical aperture and enables arbitrary aperture scaling. Dual-polarized radiators are combined with calibrated complex receive coefficients to synthesize linear polarization (LP), right-hand circular polarization (RHCP), and left-hand circular polarization (LHCP). The design burden of the electrically large shared aperture is reduced by using theoretical estimates for scan matching and inter-band isolation before full shared-aperture verification. Simulated and measured results demonstrate axial ratios below 0.1 dB in the target S- and X-band receiving bands over a +/-50 deg scan range. The prototypes are validated using two approaches: passive measurements, where the element responses are measured individually, and RF system-on-chip-based active measurements, where all available receive channels are measured simultaneously. The results confirm that the proposed SAPAA provides wide-angle scanning, very high polarization purity, and polarization-reconfigurable operation for multi-mission SATCOM ground terminals.

physics.app-ph↗

Quasioptic, Calibrated, Full 2-port Measurements of Cryogenic Devices under Vacuum in the 220-330 GHz Band

A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing S-parameters of devices in the 220-330 GHz (WR-3.4) frequency range, from room temperature down to 4.8 K. The devices were measured through vacuum windows via focused beam radiation. A de-embedding method employing line-reflect-match (LRM) calibration was established to account for the effects of optical components and vacuum windows. The setup provides all four S-parameters with the reference plane located inside the cryostat, and achieves a return loss of 30 dB with an empty holder. System validation was performed with measurements of cryogenically cooled devices, such as bare silicon wafers and stainless-steel frequency-selective surface (FSS) bandpass filters, and superconducting bandpass FSS fabricated in niobium. A permittivity reduction of Si based on 4-GHz resonance shift was observed concomitant with a drop in temperature from 296 K to 4.8 K. The stainless steel FSS measurements revealed a relatively temperature invariant center frequency and return loss level of 263 GHz and 35 dB on average, respectively. Finally, a center frequency of 257 GHz was measured with the superconducting filters, with return loss improved by 7 dB on average at 4.8 K. To the best of our knowledge, this is the first reported attempt to scale LRM calibration to 330 GHz and use it to de-embed the impact of optics and cryostat from cryogenically cooled device S-parameters.

physics.ins-det↗

A Telecentric Offset Reflective Imaging System (TORIS) for Terahertz Imaging and Spectroscopy

Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics due to its non-ionizing radiation and high sensitivity to water content. However, conventional THz imaging systems face limitations such as slow mechanical scanning, restricted field of view, and poor telecentricity. To overcome these challenges, we introduce the Telecentric Offset Reflective Imaging System (TORIS), a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. The system employs a telecentric f-theta lens and is validated using ray tracing and physical optics simulations. It achieves uniform resolution across a 50 mm x 50 mm field of view without the need for mechanical translation stages. Broadband spectral imaging of a USAF resolution test target across WR-2.2 (325-500 GHz) and WR-1.5 (500-700 GHz) frequency bands demonstrates consistent beam focus and minimal distortion, with a maximum deviation of 2.7 degrees from normal incidence and a beam waist of 2.1 lambda at the field edge in the WR-1.5 band. The system's sensitivity to hydration dynamics is further validated through imaging of wet tissue paper, capturing temporal changes in water content. In vivo imaging of human skin after capsaicin patch application reveals localized hydration variations due to biochemical response and adhesive removal. These findings confirm the system's potential for real-time hydration sensing and dermatological evaluation. TORIS sets a new benchmark in THz imaging, with applications in clinical diagnostics, wound assessment, and material characterization.

physics.optics↗

Human Skin Permittivity Characterization for Mobile Handset Evaluation at Sub-THz

This manuscript proposes a method for characterizing the complex permittivity of the human finger skin based on an open-ended waveguide covered with a thin dielectric sheet at sub-terahertz frequencies. The measurement system is initially analyzed through full-wave simulations with a detailed finger model. Next, the model is simplified by replacing the finger with an infinite sheet of human skin to calculate the forward electromagnetic problem related to the permittivity characterization. Following this, a radial basis network is employed to train the inverse problem solver. Finally, the complex permittivities of finger skins are characterized for 10 volunteers. The variations in complex relative permittivity across different individuals and skin regions are analyzed, revealing a deviation of $<\pm 1.5$ for both the dielectric constants and loss factors across 140 to 220 GHz. Repeated measurements at the same location on the finger demonstrate good repeatability with a relative estimation uncertainty $<\pm 1.5\%$.

eess.SP↗

Permittivity Characterization of Human Skin Based on a Quasi-optical System at Sub-THz

This paper introduces a novel approach to experimentally characterize effective human skin permittivity at sub-Terahertz (sub-THz) frequencies, specifically from $140$~to $210$~GHz, utilizing a quasi-optical measurement system. To ensure accurate measurement of the reflection coefficients of human skin, a planar, rigid, and thick reference plate with a low-loss dielectric is utilized to flatten the human skin surface. A permittivity characterization method is proposed to reduce permittivity estimation deviations resulting from the pressure effects on the phase displacements of skins under the measurements but also to ensure repeatability of the measurement. In practical permittivity characterizations, the complex permittivities of the finger, palm, and arm of seven volunteers show small standard deviations for the repeated measurements, respectively, while those show significant variations across different regions of the skins and for different persons. The proposed measurement system holds significant potential for future skin permittivity estimation in sub-THz bands, facilitating further studies on human-electromagnetic-wave interactions based on the measured permittivity values.

physics.med-ph↗

Mie Scattering with 3D Angular Spectrum Method

Mie theory is a powerful method to model electromagnetic scattering from a multilayered sphere. Usually, the incident beam is expanded to its vector spherical harmonic representation defined by beam shape coefficients, and the multilayer sphere scattering is obtained by the T-matrix method. However, obtaining the beam shape coefficients for arbitrarily shaped incident beams has limitations on source locations and requires different methods when the incident beam is defined inside or outside the computational domain or at the scatterer surface. We propose a 3D angular spectrum method for defining beam shape coefficients from arbitrary source field distributions. This method enables the placement of the sources freely within the computational domain without singularities, allowing flexibility in beam design. We demonstrate incident field synthesis and spherical scattering by comparing morphology-dependent resonances to known values, achieving excellent matching and high accuracy. Additionally, we present mathematical proof to support our proposal. The proposed method has significant benefits for optical systems and inverse beam design. It allows for the analysis of electromagnetic forward/backward propagation between optical elements and spherical targets using a single method. It is also valuable for optical force beam design and analysis.

physics.optics↗

Submillimeter-wave cornea phantom sensing over an extended depth of field with an axicon-generated Bessel beam

The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets demonstrate a monotonically decreasing, band integrated, backscatter intensity for increasing radius of curvature from 7 - 11 mm, when lens reflector and optical axis are aligned. Further, for radii >= 9.5 mm, maximum signal was obtained with a 1 mm transverse displacement between lens and reflector optical axes arising from spatial correlation between main lobe and out of phase side lobes. Thickness and permittivity parameter estimation experiments were performed on an 8 mm radius of curvature, 1 mm thick fused quartz dome over a 10 mm axial span. Extracted thickness and permittivity varied by less than ~ 25 $μ$m and 0.2 respectively after correction for superluminal velocity. Estimated water permittivity and thickness of water backed gelatin phantoms showed significantly more variation due to a time varying radius of curvature.

physics.med-ph↗

Coupling to longitudinal modes in spherical thin shells illuminated by submillimeter wave Gaussian beam: applications to corneal sensing

Coupling to longitudinal modes of thin spherical shells, under Gaussian-beam illumination, was explored with a theoretical method based on Fourier-optics analysis and vector spherical harmonics. The illumination frequency band was fixed between 100-600 GHz and the outer spherical shell radius of curvature and thickness are 7.5 mm and 0.5 mm, respectively. The shell material was either the lossless cornea or an aqueous effective media representing the cornea. Six different beam-target strategies were introduced being potential candidates for maximum coupling. Two dispersion-tuned beam ensembles with strongly frequency-dependent phase center location have been created with a fixed incident beam 1/e radius and radius of curvature called forward strategies. These computations of different alignments were continued with four beam ensembles of frequency-invariant phase center, constructed from fits to experimental data, oriented at four different axial locations with respect to the spherical shell center of curvature, they are called reverse strategies. Coupling efficiency for all strategies was calculated for different targets including PEC sphere, air-core, and PEC core covered by a cornea loss-free layer and cornea. All scattering strategies contrasted to scattering from equivalent planar targets as a reference with maximum coupling. The results show that, under an ideal calibration, forward strategies are a closer approximation to the plane-wave condition. However, target properties influence the coupling efficiency remarkably for instance the observed difference in cornea scattering is vanishingly small as dielectric loss limits walk-off loss. Furthermore, under perturbed calibration, the forward strategies showed less sensitivity.

physics.med-ph↗

Extreme Asymmetry in Metasurfaces via Evanescent Fields Engineering: Angular-Asymmetric Absorption

On the quest towards full control over wave propagation, the development of compact devices that allow asymmetric response is a challenge. In this Letter, we introduce a new paradigm for the engineering of asymmetry in planar structures, revealing and exploiting unilateral excitation of evanescent waves. We test the idea with the design and experimental characterization of a metasurface for angular-asymmetric absorption. The results show that the contrast ratio of absorption (the asymmetry level) can be arbitrarily engineered from zero to infinity for waves coming from two oppositely tilted angles. We demonstrate that the revealed asymmetry effects cannot be realized using conventional diffraction gratings, reflectarrays, and phase-gradient metasurfaces. This Letter opens up promising possibilities for wave manipulation via evanescent waves engineering with applications in one-side detection and sensing, angle-encoded steganography, flat nonlinear devices and shaping the scattering patterns of various objects.

physics.app-ph↗