Single-electron detection in a high-purity Ge device

High-purity germanium (HPGe) detectors are among the most powerful instruments for gamma ray spectroscopy, combining exceptional energy resolution with large active volumes. Although they operate close to the fundamental resolution limit at high energies, their performance at very low energies has long been limited by electronic noise, restricting detection thresholds to above approximately 30 electron-hole pairs ($\sim$100 eV). Here we introduce a cryogenic HPGe detector architecture that achieves single electron-hole pair sensitivity by calorimetrically measuring ionization at temperatures near 20 mK. The device integrates a NbSi transition-edge sensor into a point-contact-inspired geometry, concentrating athermal phonon energy generated during charge drift and enabling eV-scale sensitivity ultimately set by the semiconductor band gap. Beyond single-charge detection, the device rejects the low-energy excess background that limits existing cryogenic low-threshold technologies, establishing a pathway towards discrimination between electron- and nuclear-recoil events below 100 eV. These advances open a route towards next-generation detectors for direct dark matter searches, coherent elastic neutrino-nucleus scattering, and nuclear reactor monitoring for non-proliferation applications.

physics.ins-det↗

Characterization of Aluminum Microwave SQUID Multiplexers for CE$ν$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($μ$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $μΦ_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $μΦ_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $μ$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $μΦ_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $μ$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det↗

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex↗

Characterization of the phonon sensor of the CRYOSEL detector with IR photons

The sensitivities of light Dark Matter (DM) particle searches with cryogenic detectors are mostly limited by large backgrounds of events that do not produce ionization signal. The CRYOSEL project develops a new technique where this background in a germanium cryogenic detector is rejected by using the signals from a Superconducting Single Electron Device (SSED) sensor designed to detect the phonons emitted through the Neganov-Trofimov-Luke effect by the e$^-$h$^+$ pairs as they drift in a close-by very high-field region. A tag on signals from this device should suppress the heat-only background. The measurement of the response to IR laser pulses of the first CRYOSEL prototype show the relevance of such sensor technology.

physics.ins-det↗

Paarl Africa Underground Laboratory (PAUL)

Establishing a deep underground physics laboratory to study, amongst others, double beta decay, geoneutrinos, reactor neutrinos and dark matter has been discussed for more than a decade within the austral African physicists' community. PAUL, the Paarl Africa Underground Laboratory, is an initiative foreseeing an open international laboratory devoted to the development of competitive science in the austral region. It has the advantage that the location, the Huguenot tunnel, exists already and the geology and the environment of the site is appropriate for an experimental facility. The paper describes the PAUL initiative, presents the physics prospects and discusses the capacity for building the future experimental facility.

hep-ex↗

The EDELWEISS Experiment : Status and Outlook

The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.

astro-ph↗