SearcharxivSearch

arXiv subjects

Julien Billard

Publications and source records attributed to Julien Billard.

8 recordsLinked to original sources

Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $\mu\Phi_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $\mu\Phi_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $\mu$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $\mu\Phi_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $\mu$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex

Characterization of the phonon sensor of the CRYOSEL detector with IR photons

The sensitivities of light Dark Matter (DM) particle searches with cryogenic detectors are mostly limited by large backgrounds of events that do not produce ionization signal. The CRYOSEL project develops a new technique where this background in a germanium cryogenic detector is rejected by using the signals from a Superconducting Single Electron Device (SSED) sensor designed to detect the phonons emitted through the Neganov-Trofimov-Luke effect by the e$^-$h$^+$ pairs as they drift in a close-by very high-field region. A tag on signals from this device should suppress the heat-only background. The measurement of the response to IR laser pulses of the first CRYOSEL prototype show the relevance of such sensor technology.

physics.ins-det

Calorimetric Detection of Dark Matter

Dark matter direct detection experiments are designed to look for the scattering of dark matter particles that are assumed to move with virial velocities $\sim 10^{-3}$. At these velocities, the energy deposition in the detector is large enough to cause ionization/scintillation, forming the primary class of signatures looked for in such experiments. These experiments are blind to a large class of dark matter models where the dark matter has relatively large scattering cross-sections with the standard model, resulting in the dark matter undergoing multiple scattering with the atmosphere and the rock overburden, and thus slowing down considerably before arriving at underground detectors. We propose to search for these kinds of dark matter by looking for the anomalous heating of a well shielded and sensitive calorimeter. In this detector concept, the dark matter is thermalized with the rock overburden but is able to pierce through the thermal shields of the detector causing anomalous heating. Using the technologies under development for EDELWEISS and SuperCDMS, we estimate the sensitivity of such a calorimetric detector. In addition to models with large dark matter - standard model interactions, these detectors also have the ability to probe dark photon dark matter.

hep-ph

Direct Detection of Dark Matter -- APPEC Committee Report

This Report provides an extensive review of the experimental programme of direct detection searches of particle dark matter. It focuses mostly on European efforts, both current and planned, but does it within a broader context of a worldwide activity in the field. It aims at identifying the virtues, opportunities and challenges associated with the different experimental approaches and search techniques. It presents scientific and technological synergies, both existing and emerging, with some other areas of particle physics, notably collider and neutrino programmes, and beyond. It addresses the issue of infrastructure in light of the growing needs and challenges of the different experimental searches. Finally, the Report makes a number of recommendations from the perspective of a long-term future of the field. They are introduced, along with some justification, in the opening Overview and Recommendations section and are next summarised at the end of the Report. Overall, we recommend that the direct search for dark matter particle interactions with a detector target should be given top priority in astroparticle physics, and in all particle physics, and beyond, as a positive measurement will provide the most unambiguous confirmation of the particle nature of dark matter in the Universe.

hep-ex

Contact-less phonon detection with massive cryogenic absorbers

We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited on another wafer; the sensor, a Kinetic Inductance Detector (KID), is read-out without any physical contact or wiring to the absorber. The resonator demonstrates excellent electrical properties, particularly in terms of its internal quality factor. The detection of alphas and gammas in the massive absorber is achieved, with an RMS energy resolution of about 1.4 keV, which is already interesting for particle physics applications. The resolution of this prototype detector is mainly limited by the low (about 0.3%) conversion efficiency of deposited energy to superconducting excitations (quasi-particles). The demonstrated technique can be further optimized, and used to produce large arrays of a-thermal phonon detectors, for use in rare events searches such as: dark matter direct detection,neutrino-less double beta decay, or coherent elastic neutrino-nucleus scattering.

physics.ins-det

Prospects for exploring New Physics in Coherent Elastic Neutrino-Nucleus Scattering

Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) is a Standard Model process that, although predicted for decades, has only been detected recently by the COHERENT collaboration. Now that CE$ν$NS has been discovered, it provides a new probe for physics beyond the Standard Model. We study the potential to probe New Physics with CE$ν$NS through the use of low temperature bolometers at a reactor source. We consider contributions to CE$ν$NS due to a neutrino magnetic moment (NMM), Non-Standard Interactions (NSI) that may or may not change flavor, and simplified models containing a massive scalar or vector mediator. Targets consisting of Ge, Zn, Si, CaWO$_4$, and Al$_2$O$_3$ are examined. We show that by reaching a percentage-level precision measurement on the CE$ν$NS energy spectrum down to $\mathcal{O}(10)$ eV, forthcoming experiments will improve by two orders of magnitude both the CE$ν$NS-based NMM limit and the search for new massive mediators. Additionally, we demonstrate that such dedicated low-threshold CE$ν$NS experiments will lead to unprecedented constraints on NSI parameters (particularly when multiple targets are combined) which will have major implications for the global neutrino physics program.

hep-ph

Readout strategies for directional dark matter detection beyond the neutrino background

The search for weakly interacting massive particles (WIMPs) by direct detection faces an encroaching background due to coherent neutrino-nucleus scattering. As the sensitivity of these experiments improves, the question of how to best distinguish a dark matter signal from neutrinos will become increasingly important. A proposed method of overcoming this so-called 'neutrino floor' is to utilize the directional signature that both neutrino and dark matter induced recoils possess. We show that directional experiments can indeed probe WIMP-nucleon cross-sections below the neutrino floor with little loss in sensitivity due to the neutrino background. In particular we find at low WIMP masses (around 6 GeV) the discovery limits for directional detectors penetrate below the non-directional limit by several orders of magnitude. For high WIMP masses (around 100 GeV), the non-directional limit is overcome by a factor of a few. Furthermore we show that even for directional detectors which can only measure 1- or 2-dimensional projections of the 3-dimensional recoil track, the discovery potential is only reduced by a factor of 3 at most. We also demonstrate that while the experimental limitations of directional detectors, such as sense recognition and finite angular resolution, have a detrimental effect on the discovery limits, it is still possible to overcome the ultimate neutrino background faced by non-directional detectors.

astro-ph.CO