Searcharxiv⌕ Search

arXiv subjects

K. G. Leach

Publications and source records attributed to K. G. Leach.

At least 37 records · Page 2Linked to original sources

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det↗

Collision-Induced Dissociation at TRIUMF's Ion Trap for Atomic and Nuclear science

The performance of high-precision mass spectrometry of radioactive isotopes can often be hindered by large amounts of contamination, including molecular species, stemming from the production of the radioactive beam. In this paper, we report on the development of Collision-Induced Dissociation (CID) as a means of background reduction for experiments at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This study was conducted to characterize the quality and purity of radioactive ion beams and the reduction of molecular contaminants to allow for mass measurements of radioactive isotopes to be done further from nuclear stability. This is the first demonstration of CID at an ISOL-type radioactive ion beam facility, and it is shown that molecular contamination can be reduced up to an order of magnitude.

nucl-ex↗

Improved Limit on Tensor Currents in the Weak Interaction from $^8$Li $β$ Decay

The electroweak interaction in the Standard Model (SM) is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this work, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β$-$\barν$ correlation of trapped $^{8}$Li ions with the Beta-decay Paul Trap. We find $a_{βν} = -0.3325 \pm 0.0013_{stat} \pm 0.0019_{syst}$ at $1σ$ for the case of coupling to right-handed neutrinos $(C_T=-C_T')$, which is consistent with the SM prediction.

nucl-ex↗

High-precision half-life determination of $^{14}$O via direct $β$ counting

The half-life of the superallowed Fermi $β^+$ emitter $^{14}$O was determined to high precision via a direct $β$ counting experiment performed at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF. The result, $T_{1/2}$($^{14}$O) = 70619.2(76) ms, is consistent with, but is more precise than, the world average obtained from 11 previous measurements. Combining the $^{14}$O half-life deduced in the present work with the previous most precise measurements of this quantity leads to a reduction in the overall uncertainty, by nearly a factor of 2. The new world average is $T_{1/2}$($^{14}$O) = 70619.6(63) ms with a reduced $χ^2$ value of 0.87 obtained from 8 degrees of freedom.

nucl-ex↗

NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity

The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

nucl-ex↗

Development of a $^{127}$Xe calibration source for nEXO

We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

physics.ins-det↗

Isospin Mixing and the Cubic Isobaric Multiplet Mass Equation in the Lowest T = 2, A = 32 Quintet

The isobaric multiplet mass equation (IMME) is known to break down in the first T = 2, A = 32 isospin quintet. In this work we combine high-resolution experimental data with state-of-the-art shell-model calculations to investigate isospin mixing as a possible cause for this violation. The experimental data are used to validate isospin-mixing matrix elements calculated with newly developed shell-model Hamiltonians. Our analysis shows that isospin mixing with nonanalog T = 1 states contributes to the IMME breakdown, making the requirement of an anomalous cubic term inevitable for the multiplet.

nucl-ex↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time projection chambers (TPCs) to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for $0νββ$ at half-life sensitivities as long as $10^{30}$ yr.

physics.ins-det↗

The BeEST Experiment: Searching for Beyond Standard Model Neutrinos using $^7$Be Decay in STJs

Precision measurements of nuclear $β$ decay are among the most sensitive methods to probe beyond Standard Model (BSM) physics in the neutrino sector. In particular, momentum conservation between the emitted decay products in the final state is sensitive to any massive new physics that couples to the neutrino mass. One way to observe these momentum recoil effects experimentally is through high-precision measurements of electron-capture (EC) nuclear decay, where the final state only contains the neutrino and a recoiling atom. The BeEST experiment precisely measures the eV-scale radiation that follows the radioactive decay of $^7$Be implanted into sensitive superconducting tunnel junction (STJ) quantum sensors. STJs are ideally suited for measurements of this type due to their high resolution at the low recoil energies in EC decay, and their high-rate counting capabilities. We present the motivation for the BeEST experiment and describe the various phases of the project.

nucl-ex↗

Spectroscopy of states in $^{136}\rm{Ba}$ using the $^{138}\rm{Ba}(p,t)$ reaction

Background: The $^{136}$Ba isotope is the daughter nucleus in $^{136}$Xe $ββ$ decay. It also lies in a shape transitional region of the nuclear chart, making it a suitable candidate to test a variety of nuclear models. Purpose: To obtain spectroscopic information on states in $^{136}$Ba, which will allow a better understanding of its low-lying structure. These data may prove useful to constrain future $^{136}$Xe $\to$ $^{136}$Ba neutrinoless $ββ$ decay matrix element calculations. Methods: A $^{138}\mathrm{Ba}(p,t)$ reaction was used to populate states in $^{136}$Ba up to approximately 4.6 MeV in excitation energy. The tritons were detected using a high-resolution Q3D magnetic spectrograph. A distorted wave Born approximation (DWBA) analysis was performed for the measured triton angular distributions. Results: One hundred and two excited states in $^{136}$Ba were observed, out of which fifty two are reported for the first time. Definite spin-parity assignments are made for twenty six newly observed states, while previously ambiguous assignments for twelve other states are resolved.

nucl-ex↗

Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

physics.ins-det↗

Testing isospin symmetry breaking in ab initio nuclear theory

In this work we present the first steps towards benchmarking isospin symmetry breaking in ab initio nuclear theory for calculations of superallowed Fermi $β$-decay. Using the valence-space in-medium similarity renormalization group, we calculate b and c coefficients of the isobaric multiplet mass equation, starting from two different Hamiltonians constructed from chiral effective field theory. We compare results to experimental measurements for all T=1 isobaric analogue triplets of relevance to superallowed $β$-decay for masses A=10 to A=74 and find an overall agreement within approximately 250 keV of experimental data for both b and c coefficients. A greater level of accuracy, however, is obtained by a phenomenological Skyrme interaction or a classical charged-sphere estimate. Finally, we show that evolution of the valence-space operator does not meaningfully improve the quality of the coefficients with respect to experimental data, which indicates that higher-order many-body effects are likely not responsible for the observed discrepancies.

nucl-th↗

Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage

nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.

physics.ins-det↗

High-Precision Branching Ratio Measurement and Spin Assignment Implications for $^{62}$Ga Superallowed $β$ Decay

A high-precision branching ratio measurement for the superallowed Fermi $β^{+}$ emitter $^{62}$Ga was performed with the Gamma-Ray Infrastructure for Fundamental Investigations of Nuclei (GRIFFIN) spectrometer at the Isotope Separator and Accelerator (ISAC) radioactive ion beam facility at TRIUMF. The high efficiency of the GRIFFIN spectrometer allowed 63 $γ$-ray transitions, with intensities down to $\approx$1 part per million (ppm) per $^{62}$Ga $β^{+}$ decay, to be placed in the level scheme of the daughter nucleus $^{62}$Zn, establishing the superallowed $β$ branching ratio for $^{62}$Ga decay to be 99.8577$^{+0.0023}_{-0.0029}\%$, a factor of 4 more precise than the previous world average. For several cascades, $γ-γ$ angular correlation measurements were performed to assign spins and/or determine the mixing ratios of transitions. In particular, the spin of the 2.342 MeV excited state in the daughter nucleus $^{62}$Zn was definitively assigned as $J = 0$. This assignment resolves a discrepancy between previous measurements and has important implications for the isospin symmetry breaking correction, $δ_{C1}$, in $^{62}$Ga superallowed Fermi $β$ decay.

nucl-ex↗

Spectroscopic study of $^{47}$Ca from the $β^-$ decay of $^{47}$K

The $β^-$ decay of $^{47}$K to $^{47}$Ca is an appropriate mechanism for benchmarking interactions spanning the $sd$ and $pf$ shells, but current knowledge of the $β^-$-decay scheme is limited. We have performed a high-resolution, high-efficiency study of the $β^-$-decay of $^{47}$K with the GRIFFIN spectrometer at TRIUMF-ISAC. The study revealed 48 new transitions, a more precise value for the $^{47}$K half-life (17.38(3)~s), and new spin and parity assignments for eight excited states. Levels placed for the first time here raise the highest state observed in $β^-$ decay to within 568(3) keV of the $Q$-value and confirm the previously measured large $β^-$-decay branching ratios to the low-lying states. Previously unobserved $β^-$-feeding to 3/2$^+$ states between 4.5 and 6.1~MeV excitation energy was identified with a total $β^-$-feeding intensity of 1.29(2)\%. The sum of the $B(GT)$ values for these states indicates that the $1s_{1/2}$ proton hole strength near this excitation energy is comparable to the previously known $1s_{1/2}$ proton and neutron hole strengths near 2.6 MeV.

nucl-ex↗

Absence of Low-Energy Shape Coexistence in $^{80}$Ge: The Nonobservation of a Proposed Excited 0$_2^+$ Level at 639 keV

The $^{80}$Ge structure was investigated in a high-statistics $β$-decay experiment of $^{80}$Ga using the GRIFFIN spectrometer at TRIUMF-ISAC through $γ$, $β$-$e$, $e$-$γ$ and $γ$-$γ$ spectroscopy. No evidence was found for the recently reported 0$_2^{+}$ 639-keV level suggested as evidence for low-energy shape coexistence in $^{80}$Ge. Large-scale shell model calculations performed in $^{78,80,82}$Ge place the $0^{+}_{2}$ level in $^{80}$Ge at 2\,MeV. The new experimental evidence combined with shell model predictions indicate that low-energy shape coexistence is not present in $^{80}$Ge.

nucl-ex↗

Limits on the Existence of sub-MeV Sterile Neutrinos from the Decay of $^7$Be in Superconducting Quantum Sensors

Sterile neutrinos are natural extensions to the standard model of particle physics and provide a possible portal to the dark sector. We report a new search for the existence of sub-MeV sterile neutrinos using the decay-momentum reconstruction technique in the decay of $^7$Be. The experiment measures the total energy of the $^7$Li daughter atom from the electron capture decay of $^7$Be implanted into sensitive superconducting tunnel junction (STJ) quantum sensors. This first experiment presents data from a single STJ operated at a low count rate for a net total of 28 days, and provides exclusion limits on sterile neutrinos in the mass range from 100 to 850 keV that improve upon previous work by up to an order of magnitude.

nucl-ex↗

Direct measurement of the $^7$Be $L/K$ capture ratio in Ta-based superconducting tunnel junctions

We report a high-statistics measurement of the $L/K$ orbital electron capture (EC) ratio in $^7$Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction (STJ) radiation detector that was used to identify the signals from different decay channels. The measured $L/K$ capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus, and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. This is the first experiment that uses STJs for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

nucl-ex↗