SearcharxivSearch

arXiv subjects

K. Nishimura

Publications and source records attributed to K. Nishimura.

At least 19 recordsLinked to original sources

Design and Commissioning of Readout Electronics for a $K_L^0$ and $\mu$ Detector at the Belle II Experiment

The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. We describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.

hep-ex

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm $\times$ 56 mm $\times$ 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. We calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be 128 ($\pm$4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2-by-4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

physics.ins-det

Enhanced low-energy supernova burst detection in large liquid argon time projection chambers enabled by Q-Pix

The detection of neutrinos from core-collapse supernovae may reveal important process features as well as neutrino properties. The detection of supernova neutrinos is one of the main science drivers for future kiloton-scale neutrino detectors based on liquid argon. Here we show that for such detectors the intrinsically 3D readout in Q-Pix offers numerous advantages relative to a wire-based readout, such as higher reconstruction efficiency, lower energy threshold, considerably lower data rates, and potential pointing information.

hep-ex

Measurement of ${\mathcal B}$($B_s \rightarrow D_s X$) with $B_s$ Semileptonic Tagging

We report the first direct measurement of the inclusive branching fraction ${\mathcal B}(B_s \rightarrow D_s X)$ via $B_s$ tagging in $e^+e^-\to\Upsilon$(5S) events. Tagging is accomplished through a partial reconstruction of semileptonic decays $B_s \rightarrow D_s X \ell \nu$, where $X$ denotes unreconstructed additional hadrons or photons and $\ell$ is an electron or muon. With 121.4 fb$^{-1}$ of data collected at the $\Upsilon$(5S) resonance by the Belle detector at the KEKB asymmetric-energy $e^+ e^-$ collider, we obtain ${\mathcal B}(B_s \rightarrow D_s X)$ = $(60.2 \pm 5.8 \pm 2.3)$\%, where the first uncertainty is statistical and the second is systematic.

hep-ex

Design and Calibration of an Optically Segmented Single Volume Scatter Camera for Neutron Imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5 mm $\times$ 5 mm $\times$ 200 mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6 $\times$ 6 mm J-Series sensors arranged in an 8 $\times$ 8 array. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 30 ps to 90 ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using $^{22}$Na and $^{90}$Sr, respectively, reporting an average resolution of (12.07$\pm$0.03) mm for energy depositions between 900 keVee and 1000 keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of (14.86$\pm$0.29) mm for depositions between 900 keVee and 1000 keVee. The coincident time resolution reported between pairs of bars measured up to 400 ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

physics.ins-det

HDPython: A High Level Python Based Object-Oriented HDL Framework

We present a High-Level Python-based Hardware Description Language (HDPython), It uses Python as its source language and converts it to standard VHDL. Compared to other approaches of building converters from a high-level programming language into a hardware description language, this new approach aims to maintain an object-oriented paradigm throughout the entire process. Instead of removing all the high-level features from Python to make it into an HDL, this approach goes the opposite way. It tries to show how certain features from a high-level language can be implemented in an HDL, providing the corresponding benefits of high-level programming for the user.

cs.PL

PCI-express based high-speed readout for the BelleII DAQ upgrade

Belle II is a new-generation B-factory experiment, dedicated to exploring new physics beyond the standard model of elementary particles in the flavor sector. Belle~II started data-taking in April 2018, using a synchronous data acquisition (DAQ) system based on pipelined trigger flow control. The Belle II DAQ system is designed to handle a 30-kHz trigger rate with approximately 1% of dead time, under the assumption of a raw event size of 1 MB. The DAQ system is reliable, and the overall data-taking efficiency reached 84.2% during the run period of January 2020 to June 2020. The current readout system cannot be operated in the term of 10 years from the viewpoint of DAQ maintainability; meanwhile, the readout system is obstructing high-speed data transmission. A solution involving a PCI-express-based readout module with high data throughput of up to 100 Gb/s was adopted to upgrade the Belle II DAQ system. We particularly focused on the design of firmware and software based on this new generation of readout board, called PCIe40, with an Altera Arria 10 field-programmable gate array chip. Forty-eight GBT (GigaBit Transceiver) serial links, PCI-express hard IP-based DMA architecture, interface of timing and trigger distribution system, and slow control system were designed to integrate with the current Belle II DAQ system. This paper describes the performances accomplished during the data readout and slow control tests conducted using a test bench and a demonstration performed using on-site front-end electronics, specifically involving Belle II TOP and KLM sub-detectors.

physics.ins-det

The Payload for Ultrahigh Energy Observations (PUEO): A White Paper

The Payload for Ultrahigh Energy Observations (PUEO) long-duration balloon experiment is designed to have world-leading sensitivity to ultrahigh-energy neutrinos at energies above 1 EeV. Probing this energy region is essential for understanding the extreme-energy universe at all distance scales. PUEO leverages experience from and supersedes the successful Antarctic Impulsive Transient Antenna (ANITA) program, with an improved design that drastically improves sensitivity by more than an order of magnitude at energies below 30 EeV. PUEO will either make the first significant detection of or set the best limits on ultrahigh-energy neutrino fluxes.

astro-ph.IM

Search for $B^0$ Decays to Invisible Final States ($+\gamma$) at Belle

We report searches for $B^0\to\rm{invisible}$ and $B^0\to\rm{invisible}+\gamma$ decays, where the energy of the photon is required to be larger than 0.5 GeV. These results are obtained from a $711\,{\rm fb}^{-1}$ data sample that contains $772 \times 10^6 B\bar{B}$ pairs and was collected near the $\Upsilon\,(4S)$ resonance with the Belle detector at the KEKB $e^+ e^-$ collider. We observe no significant signal for either decay and set upper limits on their branching fractions at $90\%$ confidence level of $\mathcal{B}\,(B^0\to\rm{invisible}) < 7.8\times10^{-5}$ and $\mathcal{B}\,(B^0\to\rm{invisible}+\gamma) < 1.6\times10^{-5}$.

hep-ex

Update of inclusive cross sections of single and pairs of identified light charged hadrons

We report new measurements of the production cross sections of pairs of charged pions and kaons as a function of their fractional energies using various fractional-energy definitions. Two different fractional-energy definitions were used and compared to the conventional fractional-energy definition reported previously. The new variables aim at either identifying dihadron cross sections in terms of single-hadron fragmentation functions, or to provide a means of characterizing the transverse momentum created in the fragmentation process. The results were obtained applying the updated initial-state radiation correction used in other recent Belle publications on light-hadron production cross sections. In addition, production cross sections of single charged pions, kaons, and protons were also updated using this initial-state radiation correction. The cross sections are obtained from a $558\,{\rm fb}^{-1}$ data sample collected at the $\Upsilon(4S)$ resonance with the Belle detector at the KEKB asymmetric-energy $e^+ e^-$ collider.

hep-ex

Observation of the radiative decays of $\Upsilon(1S)$ to $\chi_{c1}$

We report the first observation of the radiative decay of the $\Upsilon(1S)$ into a charmonium state. The statistical significance of the observed signal of $\Upsilon(1S) \to \gamma \chi_{c1}$ is 6.3 standard deviations including systematics. The branching fraction is calculated to be Br($\Upsilon(1S) \to \gamma \chi_{c1}$) = (4.7^{+2.4}_{-1.8} (stat) ^{+0.4}_{-0.5} (sys)) * 10^{-5}. We also searched for $\Upsilon(1S)$ radiative decays into $\chi_{c0,2}$ and $\eta_c(1S,2S)$ and set upper limits on their branching fractions. These results are obtained from a 24.9 fb^{-1} data sample collected with the Belle detector at the KEKB asymmetric-energy $e^+e^-$ collider at a center-of-mass energy equal to the $\Upsilon(2S)$ mass using $\Upsilon(1S)$ tagging by the $\Upsilon(2S) \to \Upsilon(1S) \pi^+\pi^-$ transitions.

hep-ex

Directionally Accelerated Detection of an Unknown Second Reactor with Antineutrinos for Mid-Field Nonproliferation Monitoring

When monitoring a reactor site for nuclear nonproliferation purposes, the presence of an unknown or hidden nuclear reactor could be obscured by the activities of a known reactor of much greater power nearby. Thus when monitoring reactor activities by the observation of antineutrino emissions, one must discriminate known background reactor fluxes from possible unknown reactor signals under investigation. To quantify this discrimination, we find the confidence to reject the (null) hypothesis of a single proximal reactor, by exploiting directional antineutrino signals in the presence of a second, unknown reactor. In particular, we simulate the inverse beta decay (IBD) response of a detector filled with a 1 kT fiducial mass of Gadolinium-doped liquid scintillator in mineral oil. We base the detector geometry on that of WATCHMAN, an upcoming antineutrino monitoring experiment soon to be deployed at the Boulby mine in the United Kingdom whose design and deployment will be detailed in a forthcoming white paper. From this simulation, we construct an analytical model of the IBD event distribution for the case of one $4\mathrm{\ GWt}\pm2\%$ reactor 25 km away from the detector site, and for an additional, unknown, 35 MWt reactor 3 to 5 km away. The effects of natural-background rejection cuts are approximated. Applying the model, we predict $3\sigma$ confidence to detect the presence of an unknown reactor within five weeks, at standoffs of 3 km or nearer. For more distant unknown reactors, the $3\sigma$ detection time increases significantly. However, the relative significance of directional sensitivity also increases, providing up to an eight week speedup to detect an unknown reactor at 5 km away. Therefore, directionally sensitive antineutrino monitoring can accelerate the mid-field detection of unknown reactors whose operation might otherwise be masked by more powerful reactors in the vicinity.

physics.ins-det

Measurement of time-dependent $CP$ violation in $B^0 \to K^0_S \pi^0 \pi^0$ decays

We report a measurement of time-dependent $CP$ violation in $B^0 \to K^0_S \pi^0 \pi^0$ decays using a data sample of $772 \times 10^6$ $B\bar{B}$ pairs collected by the Belle experiment runnin g at the $\Upsilon (4S)$ resonance at the KEKB $e^+ e^-$ collider. This decay proceeds mainly via a $b\to sd\bar{d}$ "penguin" amplitude. The results are $\sin 2\phi^{\rm eff}_1 = 0.92^{+0.27}_{-0.31}~$ (stat.) $\pm 0.11$ (syst.) and $\mathcal{A} = 0.28 \pm 0.21$ (stat.) $\pm 0.04$ (syst.), which are the most precise measurements of $CP$ violati on in this decay mode to date. The value for the $CP$-violating parameter $\sin 2\phi^{\rm eff}_1$ is consistent with that obtained using decay modes proceeding via a $b\to c\bar{c}s$ "tree" amplitude.

hep-ex

Studies of MCP-PMTs in the miniTimeCube neutrino detector

This report highlights two different types of cross-talk in the photodetectors of the miniTimeCube neutrino experiment. The miniTimeCube detector has 24 $8 \times 8$-anode Photonis MCP-PMTs Planacon XP85012, totalling 1536 individual pixels viewing the 2-liter cube of plastic scintillator.

physics.ins-det

Invited Article: miniTimeCube

We present the development of the miniTimeCube (mTC), a novel compact neutrino detector. The mTC is a multipurpose detector, aiming to detect not only neutrinos but also fast/thermal neutrons. Potential applications include the counterproliferation of nuclear materials and the investigation of antineutrino short-baseline effects. The mTC is a plastic 0.2% $^{10}$B - doped scintillator (13 cm)$^3$ cube surrounded by 24 Micro-Channel Plate (MCP) photon detectors, each with an $8\times8$ anode totaling 1536 individual channels/pixels viewing the scintillator. It uses custom-made electronics modules which mount on top of the MCPs, making our detector compact and able to both distinguish different types of events and reject noise in real time. The detector is currently deployed and being tested at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) nuclear reactor (20 MW$_\mathrm{th}$) in Gaithersburg, MD. A shield for further tests is being constructed, and calibration and upgrades are ongoing. The mTC's improved spatiotemporal resolution will allow for determination of incident particle directions beyond previous capabilities.

physics.ins-det

Design and performance of the Focusing DIRC detector

We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises 1/12 of the SuperB barrel azimuthal coverage, with partial photodetector and electronics implementation. The prototype was tested in the SLAC Cosmic Ray Telescope which provided 3-D tracking of cosmic muons with an angular resolution of ~1.5 mrad, a position resolution of 4-5 mm, a start time resolution of 70 ps, and muon tracks above ~2 GeV tagged using an iron range stack. The fused silica focusing photon camera was coupled to a full-size BaBar DIRC bar box and was read out, over part of the full coverage, by 12 Hamamatsu H8500 multi-anode photomultipliers (MaPMTs) providing 768 pixels. We used waveform digitizing electronics to read out the MaPMTs. We give a detailed description of our data analysis methods and point out limitations on the present performance. We present results that demonstrate some basic performance characteristics of this design, including: (a) single photon Cherenkov angle resolutions with and without chromatic corrections, (b) signal-to-noise (S/N) ratio between the Cherenkov peak and background, which primarily consists of ambiguities of the possible photon paths from emission along the track to a given pixel, (c) dTOP = TOP_measured - TOP_expected resolutions (with TOP being the photon Time-of-Propagation in fused silica), and (d) performance of the detector in the presence of high-rate backgrounds.

physics.ins-det

The magnetic properties of $^{\rm 177}$Hf and $^{\rm 180}$Hf in the strong coupling deformed model

This paper reports NMR measurements of the magnetic dipole moments of two high-K isomers, the 37/2$^-$, 51.4 m, 2740 keV state in $^{\rm 177}$Hf and the 8$^-$, 5.5 h, 1142 keV state in $^{\rm 180}$Hf by the method of on-line nuclear orientation. Also included are results on the angular distributions of gamma transitions in the decay of the $^{\rm 177}$Hf isotope. These yield high precision E2/M1 multipole mixing ratios for transitions in bands built on the 23/2$^+$, 1.1 s, isomer at 1315 keV and on the 9/2$^+$, 0.663 ns, isomer at 321 keV. The new results are discussed in the light of the recently reported finding of systematic dependence of the behavior of the g$_{\rm R}$ parameter upon the quasi-proton and quasi-neutron make up of high-K isomeric states in this region.

nucl-ex

A 15 GSa/s, 1.5 GHz Bandwidth Waveform Digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

physics.ins-det