SearcharxivSearch

arXiv · 2010.15115

PCI-express based high-speed readout for the BelleII DAQ upgrade

Abstract

Belle II is a new-generation B-factory experiment, dedicated to exploring new physics beyond the standard model of elementary particles in the flavor sector. Belle~II started data-taking in April 2018, using a synchronous data acquisition (DAQ) system based on pipelined trigger flow control. The Belle II DAQ system is designed to handle a 30-kHz trigger rate with approximately 1% of dead time, under the assumption of a raw event size of 1 MB. The DAQ system is reliable, and the overall data-taking efficiency reached 84.2% during the run period of January 2020 to June 2020. The current readout system cannot be operated in the term of 10 years from the viewpoint of DAQ maintainability; meanwhile, the readout system is obstructing high-speed data transmission. A solution involving a PCI-express-based readout module with high data throughput of up to 100 Gb/s was adopted to upgrade the Belle II DAQ system. We particularly focused on the design of firmware and software based on this new generation of readout board, called PCIe40, with an Altera Arria 10 field-programmable gate array chip. Forty-eight GBT (GigaBit Transceiver) serial links, PCI-express hard IP-based DMA architecture, interface of timing and trigger distribution system, and slow control system were designed to integrate with the current Belle II DAQ system. This paper describes the performances accomplished during the data readout and slow control tests conducted using a test bench and a demonstration performed using on-site front-end electronics, specifically involving Belle II TOP and KLM sub-detectors.

Explore related subjects

Keep this discovery

BibTeXRIS

Q. D. Zhou, S. Yamada, P. Robbe, D. Charlet, R. Itoh, M. Nakao, S. Y. Suzuki, T. Kunigo, E. Jules, E. Plaige, M. Taurigna, H. Purwar, O. Hartbrich, M. Bessner, K. Nishimura, G. Varner, Y. -T Lai, T. Higuchi, R. Sugiura, D. Biswas, P. Kapusta. 2020-10-28. PCI-express based high-speed readout for the BelleII DAQ upgrade. https://doi.org/10.1109/tns.2021.3086526

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det