SearcharxivSearch

arXiv subjects

K. S. Kumar

Publications and source records attributed to K. S. Kumar.

At least 19 recordsLinked to original sources

Precision Neutron Skins of $^{208}$Pb and $^{48}$Ca from Parity-Violating Electron Scattering

We have measured the parity-violating elastic electron scattering asymmetry in the PREX and CREX experiments on ${}^{208}$Pb and ${}^{48}$Ca respectively; these are both doubly-magic nuclei whose excited states can be discriminated from the ground state by the high resolution spectrometers in Hall A at Jefferson Lab. This asymmetry provides a precise determination of the weak charge form factor at one $Q^2$ and pins down the neutron radius in these two nuclei in a relatively clean and model-independent way. This is because the $Z^0$ boson of the weak interaction couples primarily to neutrons. The heavier lead nucleus, with a neutron excess, provides an interpretation of the neutron skin thickness in terms of properties of bulk neutron matter. For the lighter ${}^{48}$Ca nucleus, which is also rich in neutrons, comparisons to microscopic nuclear theory calculations are sensitive to poorly constrained 3-neutron forces. The weak neutral form factors $F_W(Q^2)$ were extracted to be $0.368 \pm 0.013$ at $Q = 0.3977 {\rm\ fm}^{-1}$ for $^{208}$Pb from PREX-2 and $0.1304 \pm 0.0055$ at $Q = 0.8733 {\rm\ fm}^{-1}$ for $^{48}$Ca. The form factor differences $(F_{ch}-F_W)(Q^2)$ were calculated to be $0.041 \pm 0.013$ at $Q = 0.3977 {\rm fm}^{-1}$ for $^{208}$Pb from PREX-2 and $0.0277 \pm 0.0055$ at $Q = 0.8733 {\rm fm}^{-1}$ for $^{48}$Ca. Correcting for Coulomb distortions and using nuclear model information, we find the neutron skin thicknesses to be $R^{208}_{\rm skin} = 0.283 \pm 0.071$ fm combining PREX-1 and PREX-2 and $R^{48}_{\rm skin} = 0.121 \pm 0.035$ fm. This paper provides a full description of the special experimental and data analysis techniques employed for precisely measuring these small asymmetries.

nucl-ex

The nEXO Radioassay Program

Material radioactivity compilations, such as the one presented here, are important enablers of science. They are useful for the selection of radiopure materials used in the design and construction of low-energy rare-event search experiments. They allow researchers developing such experiments to save time on material studies and avoid costly duplication of effort. The data presented here were generated in support of the planned nEXO double-beta decay search. This work contains among the most restrictive constraints on the natural radioactivity content of materials of general interest to the low-radioactivity community, found in any tabulation of this kind. In this study, various techniques were employed; they are described here.

physics.ins-det

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This paper addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

physics.ins-det

Characterization of CRYO ASIC for charge readout in the nEXO experiment

nEXO is a proposed next-generation experiment searching for the neutrinoless double beta decay of $^{136}$Xe using a tonne-scale liquid xenon (LXe) time projection chamber (TPC). To image the ionization signals from events in the liquid xenon, the detector will employ metallized fused-silica charge collection tiles instrumented with cryogenic application-specific integrated circuits (ASICs), referred to as CRYO ASIC, which are designed to operate directly in LXe to minimize input capacitance and pick-up noise. Here we present the performance of the CRYO ASIC mounted on an auxiliary printed circuit board and evaluated both in a cryogenic environmental chamber and in a dedicated LXe test stand. We demonstrate that the ASICs achieve the desired performance at liquid xenon temperatures, showing a gain stability better than 0.2% over 24-hour operation and reliable in-situ calibration using an on-chip pulser. In the LXe test stand, we show that boiling caused by the chip heat dissipation can be mitigated by operating the system above ~0.1 MPa. The in-LXe noise measured agrees with simulation, which indicates it the $150~e^-$ design requirement can be satisfied. These results establish CRYO ASIC as a viable low-noise in-LXe charge readout solution for nEXO.

physics.ins-det

Search for Double Beta Decays of $^{134}$Xe with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010 and 2018 and was designed to search for double beta decay of $^{136}$Xe. Data was acquired in two phases separated by a period of detector upgrades. We report on the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decay of $^{134}$Xe with Phase II EXO-200 data, with median 90% C.L. exclusion sensitivity $T_{1/2}^{0\nu} \geq 3.7\times 10^{23}$ yr and $T_{1/2}^{2\nu} \geq 2.6 \times 10^{21}$ yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of $^{134}$Xe of $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ (90% C.L.) and the second strongest constraint on the two-neutrino decay of $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ (90% C.L.), a 3-fold improvement over the EXO-200 Phase I measurement. New constraints are also set for the $2\nu\beta\beta$ and $0\nu\beta\beta$ decays of $^{134}$Xe to the lowest excited state of $^{134}$Ba.

nucl-ex

Sensitivity of nEXO to $^{136}$Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, $\nu_e + ^{136}$Xe$\rightarrow ^{136}$Cs$^* + e^-$, as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of $^{136}$Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of $10^{-9}$, enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of CNO solar neutrinos with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement towards addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the $^7$Be neutrinos with a precision of $\sigma \leq 1.5$ keV and could determine the survival probability of $^{7}$Be and $pep$ solar $\nu_e$ with precision comparable to state-of-the-art. These quantities are sensitive to the Sun's core temperature and to non-standard neutrino interactions, respectively. Furthermore, the strong background suppression would allow nEXO to search for for charged-current interactions of fermionic dark matter in the mass range $m_\chi$ = $0.668$-$7$ MeV with a sensitivity up to three orders of magnitude better than current limits.

nucl-ex

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $\mu$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

physics.ins-det

The EMC Effect of Tritium and Helium-3 from the JLab MARATHON Experiment

Measurements of the EMC effect in the tritium and helium-3 mirror nuclei are reported. The data were obtained by the MARATHON Jefferson Lab experiment, which performed deep inelastic electron scattering from deuterium and the three-body nuclei, using a cryogenic gas target system and the High Resolution Spectrometers of the Hall A Facility of the Lab. The data cover the Bjorken $x$ range from 0.20 to 0.83, corresponding to a squared four-momentum transfer $Q^2$ range from 2.7 to $11.9\gevsq$, and to an invariant mass $W$ of the final hadronic state greater than 1.84 GeV/${\it c}^2$. The tritium EMC effect measurement is the first of its kind. The MARATHON experimental results are compared to results from previous measurements by DESY-HERMES and JLab-Hall C experiments, as well as with few-body theoretical predictions.

nucl-ex

Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

physics.atom-ph

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-$\beta$ decay detector (~5 metric ton, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5-8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

hep-ph

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.

physics.ins-det

Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan

This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recommendations and justifies them in detail.

nucl-ex

Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

hep-ex

Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset

A new search for two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2\nu\beta\beta$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2\nu\beta\beta$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2\nu}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.

hep-ex

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Snowmass 2021 White Paper: Electron Ion Collider for High Energy Physics

Electron Ion Collider (EIC) is a particle accelerator facility planned for construction at Brookhaven National Laboratory on Long Island, New York by the United States Department of Energy. EIC will provide capabilities of colliding beams of polarized electrons with polarized beams of proton and light ions. EIC will be one of the largest and most sophisticated new accelerator facilities worldwide, and the only new large-scale accelerator facility planned for construction in the United States in the next few decades. The versatility, resolving power and intensity of EIC will present many new opportunities to address some of the crucial and fundamental open scientific questions in particle physics. This document provides an overview of the science case of EIC from the perspective of the high energy physics community.

hep-ph

New Measurements of the Beam-Normal Single Spin Asymmetry in Elastic Electron Scattering Over a Range of Spin-0 Nuclei

We report precision determinations of the beam normal single spin asymmetries ($A_n$) in the elastic scattering of 0.95 and 2.18~GeV electrons off $^{12}$C, $^{40}$Ca, $^{48}$Ca, and $^{208}$Pb at very forward angles where the most detailed theoretical calculations have been performed. The first measurements of $A_n$ for $^{40}$Ca and $^{48}$Ca are found to be similar to that of $^{12}$C, consistent with expectations thus demonstrating the validity of theoretical calculations for nuclei with Z~$\leq20$. We also report $A_n$ for $^{208}$Pb at two new momentum transfers (Q$^2$) extending the previous measurement. Our new data confirm the surprising result previously reported, with all three data points showing significant disagreement with the results from the $Z\leq 20$ nuclei. These data confirm our basic understanding of the underlying dynamics that govern $A_n$ for nuclei containing $\lesssim 50$ nucleons, but point to the need for further investigation to understand the unusual $A_n$ behaviour discovered for scattering off $^{208}$Pb.

nucl-ex

Search for MeV Electron Recoils from Dark Matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_\chi = 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.

hep-ex