Searcharxiv⌕ Search

arXiv subjects

K. Yoshida

Publications and source records attributed to K. Yoshida.

At least 55 records · Page 3Linked to original sources

Direct Measurement of the Cosmic-Ray Carbon and Oxygen Spectra from 10 GeV$/n$ to 2.2 TeV$/n$ with the Calorimetric Electron Telescope on the International Space Station

In this paper, we present the measurement of the energy spectra of carbon and oxygen in cosmic rays based on observations with the Calorimetric Electron Telescope (CALET) on the International Space Station from October 2015 to October 2019. Analysis, including the detailed assessment of systematic uncertainties, and results are reported. The energy spectra are measured in kinetic energy per nucleon from 10 GeV$/n$ to 2.2 TeV$/n$ with an all-calorimetric instrument with a total thickness corresponding to 1.3 nuclear interaction length. The observed carbon and oxygen fluxes show a spectral index change of $\sim$0.15 around 200 GeV$/n$ established with a significance $>3σ$. They have the same energy dependence with a constant C/O flux ratio $0.911\pm 0.006$ above 25 GeV$/n$. The spectral hardening is consistent with that measured by AMS-02, but the absolute normalization of the flux is about 27% lower, though in agreement with observations from previous experiments including the PAMELA spectrometer and the calorimetric balloon-borne experiment CREAM.

astro-ph.HE↗

$\boldsymbol{N=32}$ shell closure below calcium: Low-lying structure of $^{50}$Ar

Low-lying excited states in the $N=32$ isotope $^{50}$Ar were investigated by in-beam $γ$-ray spectroscopy following proton- and neutron-knockout, multi-nucleon removal, and proton inelastic scattering at the RIKEN Radioactive Isotope Beam Factory. The energies of the two previously reported transitions have been confirmed, and five additional states are presented for the first time, including a candidate for a 3$^-$ state. The level scheme built using $γγ$ coincidences was compared to shell-model calculations in the $sd-pf$ model space, and to ab initio predictions based on chiral two- and three-nucleon interactions. Theoretical proton- and neutron-knockout cross sections suggest that two of the new transitions correspond to $2^+$ states, while the previously proposed $4^+$ state could also correspond to a $2^+$ state.

nucl-ex↗

A two-neutron halo is unveiled in $^{29}$F

We report the measurement of reaction cross sections ($σ_R^{\rm ex}$) of $^{27,29}$F with a carbon target at RIKEN. The unexpectedly large $σ_R^{\rm ex}$ and derived matter radius identify $^{29}$F as the heaviest two-neutron Borromean halo to date. The halo is attributed to neutrons occupying the $2p_{3/2}$ orbital, thereby vanishing the shell closure associated with the neutron number $N = 20$. The results are explained by state-of-the-art shell model calculations. Coupled-cluster computations based on effective field theories of the strong nuclear force describe the matter radius of $^{27}$F but are challenged for $^{29}$F.

nucl-ex↗

Shell evolution of $N=40$ isotones towards $^{60}$Ca: First spectroscopy of $^{62}$Ti

Excited states in the $N=40$ isotone $^{62}$Ti were populated via the $^{63}$V$(p,2p)$$^{62}$Ti reaction at $\sim$200~MeV/u at the Radioactive Isotope Beam Factory and studied using $γ$-ray spectroscopy. The energies of the $2^+_1 \rightarrow 0^{+}_{\mathrm{gs}}$ and $4^+_1 \rightarrow 2^+_1$ transitions, observed here for the first time, indicate a deformed $^{62}$Ti ground state. These energies are increased compared to the neighboring $^{64}$Cr and $^{66}$Fe isotones, suggesting a small decrease of quadrupole collectivity. The present measurement is well reproduced by large-scale shell-model calculations based on effective interactions, while ab initio and beyond mean-field calculations do not yet reproduce our findings. The shell-model calculations for $^{62}$Ti show a dominant configuration with four neutrons excited across the $N=40$ gap. Likewise, they indicate that the $N=40$ island of inversion extends down to $Z=20$, disfavoring a possible doubly magic character of the elusive $^{60}$Ca.

nucl-ex↗

Swelling of doubly magic $^{48}$Ca core in Ca isotopes beyond $N=28$

Interaction cross sections for $^{42\textrm{-}51}$Ca on a carbon target at 280 MeV/nucleon have been measured for the first time. The neutron number dependence of derived root-mean-square matter radii shows a significant increase beyond the neutron magic number $N=28$. Furthermore, this enhancement of matter radii is much larger than that of the previously measured charge radii, indicating a novel growth in neutron skin thickness. A simple examination based on the Fermi-type distribution, and the Mean-Field calculations point out that this anomalous enhancement of the nuclear size beyond $N=28$ results from an enlargement of the core by a sudden increase in the surface diffuseness of the neutron density distribution, which implies the swelling of the bare $^{48}$Ca core in Ca isotopes beyond $N=28$.

nucl-ex↗

The laser-based time calibration system for the MEG II pixelated Timing Counter

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.

physics.ins-det↗

A Laser-based Time Calibration System for the MEG II Timing Counter

We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested all the optical components and the uncertainty of this method is estimated to be 24 ps. In 2017, we installed the full system into the MEG II environment and performed a commissioning run. This method shows excellent stability and consistency with another method. The proposed system provides a precise timing alignment for SiPM-based timing detectors. It also has potential in areas such as TOF-PET.

physics.ins-det↗

Direct Measurement of the Cosmic-Ray Proton Spectrum from 50 GeV to 10 TeV with the Calorimetric Electron Telescope on the International Space Station

In this paper, we present the analysis and results of a direct measurement of the cosmic-ray proton spectrum with the CALET instrument onboard the International Space Station, including the detailed assessment of systematic uncertainties. The observation period used in this analysis is from October 13, 2015 to August 31, 2018 (1054 days). We have achieved the very wide energy range necessary to carry out measurements of the spectrum from 50 GeV to 10 TeV covering, for the first time in space, with a single instrument the whole energy interval previously investigated in most cases in separate subranges by magnetic spectrometers (BESS-TeV, PAMELA, and AMS-02) and calorimetric instruments (ATIC, CREAM, and NUCLEON). The observed spectrum is consistent with AMS-02 but extends to nearly an order of magnitude higher energy, showing a very smooth transition of the power-law spectral index from -2.81 +- 0.03 (50--500 GeV) neglecting solar modulation effects (or -2.87 +- 0.06 including solar modulation effects in the lower energy region) to -2.56 +- 0.04 (1--10 TeV), thereby confirming the existence of spectral hardening and providing evidence of a deviation from a single power law by more than 3 sigma.

astro-ph.HE↗

The CALorimetric Electron Telescope (CALET) on the International Space Station: Results from the First Two Years On Orbit

The CALorimetric Electron Telescope (CALET) is a high-energy astroparticle physics space experiment installed on the International Space Station (ISS), developed and operated by Japan in collaboration with Italy and the United States. The CALET mission goals include the investigation of possible nearby sources of high-energy electrons, of the details of galactic particle acceleration and propagation, and of potential signatures of dark matter. CALET measures the cosmic-ray electron + positron flux up to 20 TeV, gamma-rays up to 10 TeV, and nuclei with Z=1 to 40 up to 1,000 TeV for the more abundant elements during a long-term observation aboard the ISS. Starting science operation in mid-October 2015, CALET performed continuous observation without major interruption with close to 20 million triggered events over 10 GeV per month. Based on the data taken during the first two-years, we present an overview of CALET observations: uses w/o major interruption 1) Electron + positron energy spectrum, 2) Nuclei analysis, 3) Gamma-ray observation including a characterization of on-orbit performance. Results of the electromagnetic counterpart search for LIGO/Virgo gravitational wave events are discussed as well.

astro-ph.HE↗

How different is the core of $^{25}$F from $^{24}$O$_{g.s.}$?

The neutron-shell structure of $^{25}$F was studied using quasi-free (p,2p) knockout reaction at 270A MeV in inverse kinematics. The sum of spectroscopic factors of $π$0d$_{5/2}$ orbital is found to be $1.0 \pm 0.3$. However, the spectroscopic factor for the ground-state to ground-state transition ($^{25}$F, $^{24}$O$_{g.s.}$) is only $0.36\pm 0.13$, and $^{24}$O excited states are produced from the 0d$_{5/2}$ proton knockout. The result shows that the $^{24}$O core of $^{25}$F nucleus significantly differs from a free $^{24}$O nucleus, and the core consists of 35% $^{24}$O$_{g.s}$. and 65% excited $^{24}$O.

nucl-ex↗

Search for GeV Gamma-ray Counterparts of Gravitational Wave Events by CALET

We present results on searches for gamma-ray counterparts of the LIGO/Virgo gravitational-wave events using CALorimetric Electron Telescope ({\sl CALET}) observations. The main instrument of {\sl CALET}, CALorimeter (CAL), observes gamma-rays from $\sim1$ GeV up to 10 TeV with a field of view of nearly 2 sr. In addition, the {\sl CALET} gamma-ray burst monitor (CGBM) views $\sim$3 sr and $\sim2π$ sr of the sky in the 7 keV -- 1 MeV and the 40 keV -- 20 MeV bands, respectively, by using two different crystal scintillators. The {\sl CALET} observations on the International Space Station started in October 2015, and here we report analyses of events associated with the following gravitational wave events: GW151226, GW170104, GW170608, GW170814 and GW170817. Although only upper limits on gamma-ray emission are obtained, they correspond to a luminosity of $10^{49}\sim10^{53}$ erg s$^{-1}$ in the GeV energy band depending on the distance and the assumed time duration of each event, which is approximately the order of luminosity of typical short gamma-ray bursts. This implies there will be a favorable opportunity to detect high-energy gamma-ray emission in further observations if additional gravitational wave events with favorable geometry will occur within our field-of-view. We also show the sensitivity of {\sl CALET} for gamma-ray transient events which is the order of $10^{-7}$~erg\,cm$^{-2}$\,s$^{-1}$ for an observation of 100~s duration.

astro-ph.HE↗

Extended Measurement of the Cosmic-Ray Electron and Positron Spectrum from 11 GeV to 4.8 TeV with the Calorimetric Electron Telescope on the International Space Station

Extended results on the cosmic-ray electron + positron spectrum from 11 GeV to 4.8 TeV are presented based on observations with the Calorimetric Electron Telescope (CALET) on the International Space Station utilizing the data up to November 2017. The analysis uses the full detector acceptance at high energies, approximately doubling the statistics compared to the previous result. CALET is an all-calorimetric instrument with a total thickness of 30 $X_0$ at normal incidence and fine imaging capability, designed to achieve large proton rejection and excellent energy resolution well into the TeV energy region. The observed energy spectrum in the region below 1 TeV shows good agreement with Alpha Magnetic Spectrometer (AMS-02) data. In the energy region below $\sim$300 GeV, CALET's spectral index is found to be consistent with the AMS-02, Fermi Large Area Telescope (Fermi-LAT) and Dark Matter Particle Explorer (DAMPE), while from 300 to 600 GeV the spectrum is significantly softer than the spectra from the latter two experiments. The absolute flux of CALET is consistent with other experiments at around a few tens of GeV. However, it is lower than those of DAMPE and Fermi-LAT with the difference increasing up to several hundred GeV. The observed energy spectrum above $\sim$1 TeV suggests a flux suppression consistent within the errors with the results of DAMPE, while CALET does not observe any significant evidence for a narrow spectral feature in the energy region around 1.4 TeV. Our measured all-electron flux, including statistical errors and a detailed breakdown of the systematic errors, is tabulated in the Supplemental Material in order to allow more refined spectral analyses based on our data.

astro-ph.HE↗

Spectroscopy of pionic atoms in $\mathbf{{}^{122}{\textbf Sn}({\textit d},{}^3{\textbf He})}$ reaction and angular dependence of the formation cross sections

We observed the atomic $1s$ and $2p$ states of $π^-$ bound to ${}^{121}{\rm Sn}$ nuclei as distinct peak structures in the missing mass spectra of the ${}^{122}{\rm Sn}(d,{}^3{\rm He})$ nuclear reaction. A very intense deuteron beam and a spectrometer with a large angular acceptance let us achieve potential of discovery, which includes capability of determining the angle-dependent cross sections with high statistics. The $2p$ state in a Sn nucleus was observed for the first time. The binding energies and widths of the pionic states are determined and found to be consistent with previous experimental results of other Sn isotopes. The spectrum is measured at finite reaction angles for the first time. The formation cross sections at the reaction angles between 0 and $2^\circ$ are determined. The observed reaction-angle dependence of each state is reproduced by theoretical calculations. However, the quantitative comparison with our high-precision data reveals a significant discrepancy between the measured and calculated formation cross sections of the pionic $1s$ state.

nucl-ex↗

Astrochemical evolution along star formation: Overview of the IRAM Large Program ASAI

Evidence is mounting that the small bodies of our Solar System, such as comets and asteroids, have at least partially inherited their chemical composition from the first phases of the Solar System formation. It then appears that the molecular complexity of these small bodies is most likely related to the earliest stages of star formation. It is therefore important to characterize and to understand how the chemical evolution changes with solar-type protostellar evolution. We present here the Large Program "Astrochemical Surveys At IRAM" (ASAI). Its goal is to carry out unbiased millimeter line surveys between 80 and 272 GHz of a sample of ten template sources, which fully cover the first stages of the formation process of solar-type stars, from prestellar cores to the late protostellar phase. In this article, we present an overview of the surveys and results obtained from the analysis of the 3 mm band observations. The number of detected main isotopic species barely varies with the evolutionary stage and is found to be very similar to that of massive star-forming regions. The molecular content in O- and C- bearing species allows us to define two chemical classes of envelopes, whose composition is dominated by either a) a rich content in O-rich complex organic molecules, associated with hot corino sources, or b) a rich content in hydrocarbons, typical of Warm Carbon Chain Chemistry sources. Overall, a high chemical richness is found to be present already in the initial phases of solar-type star formation.

astro-ph.GA↗

On-orbit Operations and Offline Data Processing of CALET onboard the ISS

The CALorimetric Electron Telescope (CALET), launched for installation on the International Space Station (ISS) in August, 2015, has been accumulating scientific data since October, 2015. CALET is intended to perform long-duration observations of high-energy cosmic rays onboard the ISS. CALET directly measures the cosmic-ray electron spectrum in the energy range of 1 GeV to 20 TeV with a 2% energy resolution above 30 GeV. In addition, the instrument can measure the spectrum of gamma rays well into the TeV range, and the spectra of protons and nuclei up to a PeV. In order to operate the CALET onboard ISS, JAXA Ground Support Equipment (JAXA-GSE) and the Waseda CALET Operations Center (WCOC) have been established. Scientific operations using CALET are planned at WCOC, taking into account orbital variations of geomagnetic rigidity cutoff. Scheduled command sequences are used to control the CALET observation modes on orbit. Calibration data acquisition by, for example, recording pedestal and penetrating particle events, a low-energy electron trigger mode operating at high geomagnetic latitude, a low-energy gamma-ray trigger mode operating at low geomagnetic latitude, and an ultra heavy trigger mode, are scheduled around the ISS orbit while maintaining maximum exposure to high-energy electrons and other high-energy shower events by always having the high-energy trigger mode active. The WCOC also prepares and distributes CALET flight data to collaborators in Italy and the United States. As of August 31, 2017, the total observation time is 689 days with a live time fraction of the total time of approximately 84%. Nearly 450 million events are collected with a high-energy (E>10 GeV) trigger. By combining all operation modes with the excellent-quality on-orbit data collected thus far, it is expected that a five-year observation period will provide a wealth of new and interesting results.

astro-ph.IM↗

Benchmarking theoretical formalisms for $(p,pn)$ reactions: the $^{15}$C($p,pn$)$^{14}$C case

[Background] Proton-induced knockout reactions of the form $(p,pN)$ have experienced a renewed interest in recent years due to the possibility of performing these measurements with rare isotopes, using inverse kinematics. Several theoretical models are being used for the interpretation of these new data, such as the distorted-wave impulse approximation (DWIA), the transition amplitude formulation of the Faddeev equations due to Alt, Grassberger and Sandhas (FAGS) and, more recently, a coupled-channels method here referred to as transfer-to-the-continuum (TC). [Purpose] Our goal is to compare the momentum distributions calculated with the DWIA and TC models for the same reactions, using whenever possible the same inputs (e.g. distorting potential). A comparison with already published results for the FAGS formalism is performed as well. [Method] We choose the $^{15}$C($p$,$pn$)$^{14}$C reaction at an incident energy of 420 MeV/u, which has been previously studied with the FAGS formalism. The knocked-out neutron is assumed to be in a $2s$ single-particle orbital. Longitudinal and transverse momentum distributions are calculated for different assumed separation energies. [Results] For all cases considered, we find a very good agreement between DWIA and TC results. The energy dependence of the distorting optical potentials is found to affect in a modest way the shape and magnitude of the momentum distributions. Moreover, when relativistic kinematics corrections are omitted, our calculations reproduce remarkably well the FAGS result. [Conclusions] The results found in this work provide confidence on the consistency and accuracy of the DWIA and TC models for analyzing momentum distributions for $(p,pn)$ reactions at intermediate energies.

nucl-th↗

The design of the MEG II experiment

The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.

physics.ins-det↗

Energy Calibration of CALET Onboard the International Space Station

In August 2015, the CALorimetric Electron Telescope (CALET), designed for long exposure observations of high energy cosmic rays, docked with the International Space Station (ISS) and shortly thereafter began tocollect data. CALET will measure the cosmic ray electron spectrum over the energy range of 1 GeV to 20 TeV with a very high resolution of 2% above 100 GeV, based on a dedicated instrument incorporating an exceptionally thick 30 radiation-length calorimeter with both total absorption and imaging (TASC and IMC) units. Each TASC readout channel must be carefully calibrated over the extremely wide dynamic range of CALET that spans six orders of magnitude in order to obtain a degree of calibration accuracy matching the resolution of energy measurements. These calibrations consist of calculating the conversion factors between ADC units and energy deposits, ensuring linearity over each gain range, and providing a seamless transition between neighboring gain ranges. This paper describes these calibration methods in detail, along with the resulting data and associated accuracies. The results presented in this paper show that a sufficient accuracy was achieved for the calibrations of each channel in order to obtain a suitable resolution over the entire dynamic range of the electron spectrum measurement.

astro-ph.IM↗