Understanding neutrino pion production with the GiBUU model

Pion production is a major source of systematic uncertainty in neutrino oscillation measurements. We report a systematic investigation of neutrino-induced pion production using MINERvA and MicroBooNE data within the GiBUU theoretical framework. The analysis begins by establishing baseline model parameters using inclusive and pionless data from MINERvA, MicroBooNE, and T2K experiments. We then examine the role of in-medium effects, including resonance broadening and nucleon-nucleon final-state interactions. While agreement with individual datasets can be achieved through specific model configurations, we demonstrate the difficulty of a unified description across all experiments: MINERvA measurements prefer minimum in-medium modifications, whereas MicroBooNE data require the maximum in-medium enhancement, revealing the complexity and richness of the underlying nuclear dynamics.

hep-ex

JUNO 20-inch PMT and electronics system characterization using large pulses of PMT dark counts at the Pan-Asia testing platform

The main goal of the JUNO experiment is to determine the neutrino mass ordering with a 20kt liquid-scintillator detector. The 20-inch PMT and its 1F3 (one for three) electronics are crucial to realize the excellent energy resolution of at least 3% at 1MeV. The knowledge on the PMT and 1F3 electronics response is critical for detector performance understanding. A study of the JUNO 20-inch PMT and 1F3 electronics system characterization is presented using large pulses of PMT dark count at the Pan-Asia testing platform in China. Thanks to its broad amplitude range and high rate, the large pulse signals are also used to investigate the PMT after pulse response.

physics.ins-det

Dark Count Rate Stability of JUNO 20-inch PMTs in Mass Testing

The Jiangmen Underground Neutrino Observatory (JUNO) is an ambitious multipurpose neutrino experiment designed to determine the neutrino mass ordering, with an impressive energy resolution goal of at least 3% at 1 MeV. To achieve a photon detection coverage of approximately 75%, JUNO will utilize two types of 20-inch photomultiplier tubes (PMTs): the large PMT (LPMT) and the microchannel plate PMT (MCP-PMT). A significant concern in high-precision neutrino measurements is the dark count rate (DCR) of PMTs, which introduces noise that can adversely affect energy measurement accuracy. During the mass testing phase of the JUNO 20-inch PMTs, comprehensive measurements of the DCR were undertaken. These measurements not only captured the DCR values of individual PMTs but also examined the stability and temperature dependence of the DCR at an operating gain of (1x10^7). This paper presents a detailed characterization of the DCR of the JUNO 20-inch PMTs, investigating factors such as cooling time, temperature variations, and long-term stability using the JUNO Pan-Asia PMT testing facilities. The results reveal distinct DCR characteristics between the two types of PMTs, providing valuable insights into the nature of DCR and its implications for JUNO's scientific objectives. In addition to performance characterization, we implemented a monitoring system to track DCR stability over time. Notably, several spikes in DCR were identified, prompting a preliminary investigation into their causes. Potential factors contributing to these spikes, such as flasher events, were explored using coincidence rate analysis and complementary imaging techniques. The findings from this study are crucial for optimizing the performance of PMTs in JUNO, ultimately aiding the experiment in achieving its goals related to neutrino physics.

physics.ins-det

A Test System for the JUNO 20-inch PMTs Prior to Installation

The JUNO experiment requires an excellent energy resolution of 3\% at 1 MeV. To achieve this objective, a total of 20,012 20-inch photomultiplier tubes (PMTs) will be deployed for JUNO, comprising 15,012 multi-channel plate (MCP) PMTs and 5,000 dynode PMTs. Currently, JUNO is in the process of detector installation, with PMTs being installed from the top to the bottom of the stainless-steel structure located in the underground experimental hall. In order to validate the functionality of the PMTs and ensure there are no malfunctions prior to installation, a test system has been established at the JUNO site, and testing is being conducted. This paper presents an overview of the test system and reports on the initial test results.

physics.ins-det

Check on the features of potted 20-inch PMTs with 1F3 electronics prototype at Pan-Asia

The Jiangmen underground neutrino observatory (JUNO) is a neutrino project with a 20-kton liquid scintillator detector located at 700-m underground. The large 20-inch PMTs are one of the crucial components of the JUNO experiment aiming to precision neutrino measurements with better than 3% energy resolution at 1 MeV. The excellent energy resolution and a large fiducial volume provide many exciting opportunities for addressing important topics in neutrino and astro-particle physics. With the container #D at JUNO Pan-Asia PMT testing and potting station, the features of waterproof potted 20-inch PMTs were measured with JUNO 1F3 electronics prototype in waveform and charge, which are valuable for better understanding on the performance of the waterproof potted PMTs and the JUNO 1F3 electronics. In this paper, basic features of JUNO 1F3 electronics prototype run at Pan-Asia will be introduced, followed by an analysis of the waterproof potted 20-inch PMTs and a comparison with the results from commercial electronics used by the container #A and #B.