Design and development of Fabry-Perot based wavelength calibration system for PARAS-2 spectrograph

Precise wavelength calibration is essential for high-precision radial velocity (RV) spectrographs, necessitating a stable calibrator that provides a dense grid of uniformly spaced lines to accurately determine stellar line positions and monitor instrumental drifts. In this work, we present the development of a cost-effective Fabry-Perot (FP) etalon-based wavelength calibrator designed to overcome the limitations of conventional sources such as hollow cathode lamps (HCLs) and iodine cells. This FP calibrator, combined with a Xenon (Xe) arc lamp assembly, has been integrated with the PARAS-2 spectrograph on the PRL 2.5m telescope at Mount Abu Observatory. Operated under controlled temperature and pressure conditions, the system generates a dense, comb-like spectrum covering 62 echelle orders with more than 10,000 well-defined and stable spectral lines, enabling precise measurement of instrumental drift. Initial results show that the free spectral range (FSR) varies from 0.16 Å~near 4000 Å~to 0.49 Å~ near 7000 Å, with a value of 0.3 Å~around the central wavelength of 5500 Å~. The estimated finesse ranges from 9 near 4000 Å~to 19 near 6900 Å, with an approximate value of 17 at 5500 Å. The temperature and pressure stability tests demonstrate RMS variations of $0.002 ^\circ\mathrm{C}$ and $5\times10^{-4}$ mbar, respectively. Based on these values, the theoretical stability of the FP wavelength calibrator is estimated to be within 10 cm/s, establishing it as a reliable alternative to Laser Frequency Combs (LFCs) for high-resolution spectroscopic calibration. We present an initial assessment of the RV stability of the FP calibrator, yielding 40-70 cm/s of relative drifts, which are up for further investigations. The observed excess over the theoretically estimated limit is likely attributable to instabilities arising from arc wandering in the xenon arc lamp.

astro-ph.IM↗

The PRL 2.5m Telescope and its First Light Instruments: FOC & PARAS-2

We present here the information on the design and performance of the recently commissioned 2.5-meter telescope at the PRL Mount Abu Observatory, located at Gurushikhar, Mount Abu, India. The telescope has been successfully installed at the site, and the Site Acceptance Test (SAT) was completed in October 2022. It is a highly advanced telescope in India, featuring the Ritchey-Chr$\acute{e}$tien optical configuration with primary mirror active optics, tip-tilt on side-port, and wave front correction sensors. Along with the telescope, its two first light instruments {namely Faint Object Camera (FOC) and PARAS-2} were also integrated and attached with it in the June 2022. {FOC is a} camera that uses a 4096 X 4112 pixels detector SDSS type filters with enhanced transmission and known as u', g', r', i', z'. It has a limiting magnitude of 21 mag in 10 minutes exposure in the r'-band. The other first light instrument PARAS-2 is a state-of-the-art high-resolution fiber-fed spectrograph operates in 380-690 nm wave-band, aimed to unveil the super-Earth like worlds. The spectrograph works at a resolution of $\sim$107,000, making it the highest-resolution spectrograph in Asia to date, which is under {ultra}-stable temperature and pressure environment, at 22.5 $\pm$ 0.001 $^{\circ}$C and 0.005 $\pm$ 0.0005 mbar, respectively. Initial calibration tests of the spectrograph using a Uranium Argon Hollow Cathode Lamp (UAr HCL) have yielded intrinsic instrumental RV stability down to 30 cm s$^{-1}$.

astro-ph.IM↗