Searcharxiv⌕ Search

arXiv subjects

Kiseki D. Nakamura

Publications and source records attributed to Kiseki D. Nakamura.

7 recordsLinked to original sources

In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber

We have newly developed a Cockcroft-Walton (CW) multiplier that can be used in a gas time projection chamber (TPC). A TPC requires a high voltage to form an electric field that drifts ionization electrons. Supplying the high voltage from outside the pressure vessel requires a dedicated high-voltage feedthrough. An alternative approach is to generate the high voltage inside the pressure vessel with a relatively low voltage introduced from outside. A CW multiplier can convert a low AC voltage input to a high DC voltage output, making it suitable for this purpose. We have integrated a CW multiplier into the AXEL (A Xenon ElectroLuminescence detector), a high pressure xenon gas TPC to search for neutrinoless double beta decay of $^{136}$Xe. It uses silicon photomultipliers to detect the ionization electrons through elecrtoluminescence, making it strong against electronic noise. Operation of the CW multiplier was successfully demonstrated; the TPC was operated for 40 days at 6.8 bar, and an energy resolution as high as (0.67 $\pm$ 0.08) % (FWHM) at 2615 keV was obtained.

physics.ins-det↗

Performance evaluation of electron multiplier tubes as a high-intensity muon beam monitor of accelerator neutrino experiments

Upgrade work towards increasing the beam intensity of the neutrino beamline at J- PARC is underway. Monitoring tertiary muon beams is essential for stable operation of the beamline. Accordingly, we plan to replace the present muon monitor sensors with electron multiplier tubes (EMTs). We investigated the radiation tolerance and linearity response of EMTs using a 90 MeV electron beam. An EMTs was irradiated with electrons up to 470 nC. EMTs show higher radiation tolerance than the Si sensors which are presently used as one of the muon monitor detectors for the T2K long-baseline neutrino experiment at J-PARC. The integrated charge yield decrease is found to be less than 8% after a beam irradiation equivalent to 132 days of operation at the future J-PARC beam power of 1.3 MW. The EMTs show linearity better than $\pm$5% up to the future beam intensity. The observed yield decrease is likely due to dynode deterioration based on the detailed investigation. The studies described here confirm that EMTs can be used as a high-intensity muon beam monitor. From the reported results, we are proceeding with the installation in the J-PARC neutrino beamline.

physics.ins-det↗

High-pressure xenon gas time projection chamber with scalable design and its performance at around the Q value of $^{136}$Xe double-beta decay

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0νββ$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons, called ELCC. ELCC is composed of multiple units, and one unit covers 48.5 $\mathrm{cm}^2$. A 180 L size prototype detector with 12 units, 672 channels, of ELCC was constructed and operated with 7.6 bar natural xenon gas to evaluate the performance of the detector at around the Q value of $^{136}$Xe $0νββ$. The obtained FWHM energy resolution is (0.73 $\pm$ 0.11) % at 1836 keV. This corresponds to (0.60 $\pm$ 0.03) % to (0.70 $\pm$ 0.21) % of energy resolution at the Q value of $^{136}Xe$ $0νββ$. This result shows the scalability of the AXEL detector with ELCC while maintaining high energy resolution. Factors determining the energy resolution were quantitatively evaluated and the result indicates further improvement is feasible. Reconstructed track images show distinctive structures at the endpoint of electron tracks, which will be an important feature to distinguish $0νββ$ signals from gamma-ray backgrounds.

physics.ins-det↗

Detection capability of Migdal effect for argon and xenon nuclei with position sensitive gaseous detectors

Migdal effect is attracting interests because of the potential to enhance the sensitivities of direct dark matter searches to the low mass region. In spite of its great importance, the Migdal effect has not been experimentally observed yet. A realistic experimental approach towards the first observation of the Migdal effect in the neutron scattering was studied with Monte Carlo simulations. In this study, potential background rate was studied together with the event rate of the Migdal effect by a neutron source. It was found that a table-top sized $\sim (30\rm cm )^3$ position-sensitive gaseous detector filled with argon or xenon target gas can detect characteristic signatures of the Migdal effect with sufficient rates (O($10^2\sim10^3$) events/day). A simulation result of a simple experimental set-up showed two significant background sources, namely the intrinsic neutrons and the neutron induced gamma-rays. These background rates were found to be much higher than those of the Migdal effect in the neutron scattering. As a consequence of this study, it is concluded that the experimental observation of the Migdal effect in the neutron scattering can be realized with a good understanding and reduction of the background.

physics.ins-det↗

Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.

physics.ins-det↗

Energy deposition on nuclear emulsion by slow recoil ions for directional dark matter searches

The electronic energy deposited on nuclear emulsions due to C ions of 5 -- 200~keV and Kr ions of 5 -- 600~keV are evaluated and compared with those due to fast ions for design and construction of fine grain nuclear emulsion for directional dark matter searches. Nuclear quenching factors and the electronic LET (linear energy transfer), the specific electronic energy deposited along the ion track, are evaluated. The so-called core and penumbra of heavy-ion track structure is modified for understanding the track due to recoil ions produced by dark matter candidate, WIMPs, striking nucleus in the AgBr crystal of nuclear emulsion. The very heavy recoil ions, 100 -- 180~keV Pb ions, produced in $α$-decay are also studied. In addition, the track structures due to proton ions of 25 -- 80~keV are evaluated to consider the influence of background neutrons in underground laboratories.

physics.ins-det↗

Development of a time projection chamber with a sheet-resistor field cage

A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than conventional TPCs with resistor-chains owing to its continuous sheet resistivity, and its production would be easier than that of conventional TPCs. The material used in this study, Achilles-Vynilas, was found to be thin, transparent, and low-radioactive. The performance test with cosmic muons showed very promising results, including the demonstration of a good tracking-performance. This type of TPC field cage can offer an alternative for the widely used conventional field cages

physics.ins-det↗