SearcharxivSearch

arXiv subjects

L. Bergé

Publications and source records attributed to L. Bergé.

At least 19 recordsLinked to original sources

The CROSS experiment: detector construction, background projection, and sensitivity to $^{100}$Mo $0\nu2β$ decay

The CROSS experiment to search for neutrinoless double-beta ($0\nu2β$) decay in $^{100}$Mo with the help of an array of scintillating cryogenic calorimeters, containing 4.9 kg of $^{100}$Mo, has been ongoing in a low-background setup at the Canfranc underground laboratory (Spain) since mid-November 2025. In this paper, we present the construction of the CROSS detector and the description of Geant4-based Monte Carlo simulations of expected background in the region of interest. The simulations predict the background index in a 100-keV-wide interval centered at the $Q$-value of $^{100}$Mo (3034 keV) on the level of 3.2(5) $\times$ 10$^{-3}$ cnts/keV/kg/yr. Taking into account an 18% deadtime induced by the muon veto cut and a typical 90% duty cycle of the facility, such background level would allow to reach the world-leading sensitivity to $^{100}$Mo $0\nu2β$ decay (lim $T_{1/2} \sim 4 \times 10^{24}$ yr) in 1 year of data taking. Considering conservatively a factor 3 (10) worse background index due to unpredictable radioactive contamination of construction materials and/or detector performance, a 2-yr-long operation of the CROSS array would be still compatible with the best (competitive) sensitivity to $0\nu2β$ decay in $^{100}$Mo.

physics.ins-det

Four-wave mixing and secondary radiations generated by nonharmonic two-color filaments in air: Influence of the Kerr and plasma nonlinearities

Four-wave mixing (FWM) is an efficient source of light waves emitted at various frequencies, usually associated with third-order optical nonlinearities. Whereas attention has mostly been paid in the past to the generation of Stokes (e.g., visible) modes by mixing two nonharmonic frequencies in degenerate FWM, the present work aims to analyze the weaker components, i.e., the anti-Stokes (resp. mid-IR) radiation and cascaded satellites, and characterize their conversion efficiency and tunability. Here we report the production of tunable mid-infrared radiation around 3.3 $μ$m delivered by two-color femtosecond filaments in air combining $\sim 800$ nm fundamental and $\sim 1.3$ $μ$m seed waves. Although the Kerr response of air plays a key role in creating both visible and mid-IR radiations, we show that plasma nonlinearities also contribute by broadening and mixing the pump frequencies. Two experimental setups are exploited to focus, separately, on the production of FWM modes and cascaded satellites - called secondary radiations. A first filamentation setup employing different focal lengths for the two colors displays an ionization-induced broadening of the mid-IR radiation during the plasma stage. A second setup focusing the two pump components over equal propagation distances allows us to unveil the secondary radiations emerging at lower intensity levels when plasma occurs. We examine which player, among the plasma- or Kerr-induced FWM, is the most active in the conversion process. Numerical simulations based on a local-current model and a unidirectional solver highlight the role of the Kerr stage in amplifying the FWM radiations prior to the development of the weaker satellites in plasma regime. Their results, agreeing well with the experimental data, demonstrate that a broad visible emission is needed to trigger secondary radiations.

physics.optics

Low Energy Phonon Bursts Created By Fast Neutron Damage

Solid state athermal phonon calorimeters used in the search for low mass dark matter or coherent neutrino-nucleus interactions have long observed a large excess of events below several hundred eV. The relaxation of damage created by the interaction of fast cosmic ray neutrons with the detector has been proposed as a source of these excess events. By comparing neutron exposed detectors to control detectors, we report the first measurement of phonon bursts caused by damage created by fast neutrons. Differences in the spectral shape, the rate dependence on thermal history, and the observed spectral rate scaled to the neutron exposure between irradiated and control detectors suggest that our observed LEE backgrounds are not dominated by neutron damage-induced phonon bursts.

physics.ins-det

Sensitivity of the CUPID experiment to $0νββ$ decay of $^{100}$Mo

CUPID is a next-generation bolometric experiment to search for neutrinoless double-beta decay ($0νββ$) of $^{100}$Mo using Li$_2$MoO$_4$ scintillating crystals. It will operate 1596 crystals at $\sim$10 mK in the CUORE cryostat at the Laboratori Nazionali del Gran Sasso in Italy. Each crystal will be facing two Ge-based bolometric light detectors for $α$ rejection. We compute the discovery and the exclusion sensitivity of CUPID to $0νββ$ in a Frequentist and a Bayesian framework. This computation is done numerically based on pseudo-experiments. For the CUPID baseline scenario, with a background and an energy resolution of $1.0 \times 10^{-4}$ counts/keV/kg/yr and 5 keV FWHM at the Q-value, respectively, this results in a Bayesian exclusion sensitivity (90% c.i.) of $\hat{T}_{1/2} > 1.6 \times 10^{27} \ \mathrm{yr}$, corresponding to the effective Majorana neutrino mass of $\hat{m}_{ββ} < \ 9.6$ -- $28 \ \mathrm{meV}$. The Frequentist discovery sensitivity (3$σ$) is $\hat{T}_{1/2}= 1.0 \times 10^{27} \ \mathrm{yr}$, corresponding to $\hat{m}_{ββ}= \ 12$ -- $36 \ \mathrm{meV}$.

nucl-ex

Muon veto system for the CROSS double-beta decay search experiment

In preparation to the CROSS experiment at the Canfranc underground laboratory (Spain) $-$ aiming to search for neutrinoless double-beta ($0νββ$) decay of $^{100}$Mo using low-temperature detectors with heat-scintillation readout $-$ we report on development of a dedicated muon veto system. The need for the muon veto in CROSS is caused by a comparatively high residual cosmic muon flux at the experimental site ($\sim$20 $μ$/m$^2$/h), being a dominant background in the region of interest (ROI) at $\sim$3 MeV. Thus, we installed the muon veto system around the CROSS low-background setup, forming four lateral, one top, and four bottom sectors. In this paper we describe the design, construction and operation of the CROSS muon veto system, as well as its optimization and validation by comparing dedicated Monte Carlo (MC) simulations of muons with low-temperature measurements in the setup. We demonstrate a stable operation of the veto system with the average trigger rates compatible with MC simulations. Also, we investigated two muon trigger logics based on coincidences with either 2 sectors or a single sector of the veto. The MC study shows that, in combination with the multiplicity cut of thermal detectors, these trigger logics allow to reject 99.2\% and 99.7\% of muon-induced events in the ROI, respectively. Despite a comparatively high dead time ($\sim$18\%) introduced by coincidences with any of nine sectors of the veto $-$ the adopted strategy $-$ the muon-induced background in the ROI of the CROSS experiment can be reduced down to $\sim$2 $\times 10^{-3}$ cnts/keV/kg/yr, i.e., an acceptable level compatible with a high-sensitivity $0νββ$ decay search foreseen in CROSS.

physics.ins-det

Cryogenic light detectors with thermal signal amplification for $0νββ$ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li$_{2}$$^{100}$MoO$_4$ crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of $O$(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

physics.ins-det

CUPID, the CUORE Upgrade with Particle IDentification

CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo with a discovery sensitivity covering the full neutrino mass regime in the inverted ordering scenario, as well as the portion of the normal ordering regime with lightest neutrino mass larger than 10 meV. With a conservative background index of 10$^{-4}$ cnts/(keV$\cdot$kg$\cdot$yr), 240 kg isotope mass, 5 keV FWHM energy resolution at 3 MeV and 10 live-years of data taking, CUPID will have a 90\% C.L. half-life exclusion sensitivity of 1.8 $\cdot$ 10$^{27}$ yr, corresponding to an effective Majorana neutrino mass ($m_{ββ}$) sensitivity of 9--15 meV, and a $3σ$ discovery sensitivity of 1 $\cdot$ 10$^{27}$ yr, corresponding to an $m_{ββ}$ range of 12--21 meV.

physics.ins-det

Simulating ultrarelativistic beam-plasma instabilities with a quasistatic particle-in-cell code

Quasistatic particle-in-cell (PIC) codes are increasingly employed to study laser or plasma wakefield accelerators. By decoupling the slow dynamics of the driver (a laser or ultrarelativistic particle beam) from the fast plasma response, these codes can reduce the computational time by several orders of magnitude compared to conventional PIC codes. In this work, we demonstrate that quasistatic PIC codes can also be utilized to investigate relativistic beam-plasma instabilities, with a focus on the oblique two-stream instability (OTSI). For this purpose, we have developed a 2D quasistatic PIC code, QuaSSis, based on a new numerical scheme that can handle transversely periodic boundary conditions, a capability absent in previous quasistatic codes. The accuracy of QuaSSis is benchmarked first against standard PIC simulations performed with the CALDER code, and then against an analytical spatiotemporal model of the OTSI. Physically, this instability grows exponentially from initial fluctuations in the particle charge or current densities. Since the numerical noise inherent to PIC simulations can mimic these fluctuations to some extent, its control is crucial to seed the beam-plasma instability at the desired amplitude. Common methods for tuning this noise involve modifying the resolution or adding filters, but these can be computationally costly when aiming at very low noise levels. Here, we show that this noise can be finely controlled by properly initializing the positions and weights of the macroparticles.

physics.plasm-ph

Searching for Beyond the Standard Model physics using the improved description of $^{100}$Mo $2νββ$ decay spectral shape with CUPID-Mo

The current experiments searching for neutrinoless double-$β$ ($0νββ$) decay also collect large statistics of Standard Model allowed two-neutrino double-$β$ ($2νββ$) decay events. These can be used to search for Beyond Standard Model (BSM) physics via $2νββ$ decay spectral distortions. $^{100}$Mo has a natural advantage due to its relatively short half-life, allowing higher $2νββ$ decay statistics at equal exposures compared to the other isotopes. We demonstrate the potential of the dual read-out bolometric technique exploiting a $^{100}$Mo exposure of 1.47 kg $\times$ y, acquired in the CUPID-Mo experiment at the Modane underground laboratory (France). We set limits on $0νββ$ decays with the emission of one or more Majorons, on $2νββ$ decay with Lorentz violation, and $2νββ$ decay with a sterile neutrino emission. In this analysis, we investigate the systematic uncertainty induced by modeling the $2νββ$ decay spectral shape parameterized through an improved model, an effect never considered before. This work motivates searches for BSM processes in the upcoming CUPID experiment, which will collect the largest amount of $2νββ$ decay events among the next-generation experiments.

nucl-ex

Development of large-volume $^{130}$TeO$_2$ bolometers for the CROSS $2β$ decay search experiment

We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to about 91%, for the CROSS double-beta decay experiment. A powder used for the crystals growth was additionally purified by the directional solidification method, resulting in the reduction of the concentration of impurities by a factor 10, to a few ppm of the total concentration of residual elements (the main impurity is Fe). The purest part of the ingot (the first ~200 mm, about 80% of the total length of the cylindrical part of the ingot) was determined by scanning segregation profiles of impurities and used for the $^{130}$TeO$_2$ powder production with no evidence of re-contamination. The crystal growth was verified with precursors produced from powder with natural Te isotopic composition, and two small-size (20x20x10 mm) samples were tested at a sea-level laboratory showing high bolometric and spectrometric performance together with acceptable $^{210}$Po content (below 10 mBq/kg). This growth method was then applied for the production of six large cubic $^{130}$TeO$_2$ crystals and 4 of them were taken randomly to be characterized at the Canfranc underground laboratory, in the CROSS-dedicated low-background cryogenic facility. Two $^{130}$TeO$_2$ samples were coated with a thin, $O$(100 nm), metal film in form of Al layer (on 4 sides) or AlPd grid (on a single side) to investigate the possibility to tag surface events by pulse-shape discrimination. Similarly to the small natural precursors, large-volume $^{130}$TeO$_2$ bolometers show high performance and even better internal purity ($^{210}$Po activity $\sim$ 1 mBq/kg, while activities of $^{228}$Th and $^{226}$Ra are below 0.01 mBq/kg), satisfying requirements for the CROSS and, potentially, next-generation experiments.

physics.ins-det

A novel mechanical design of a bolometric array for the CROSS double-beta decay experiment

The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector performance. A single module of the structure holds two scintillating bolometers (with a crystal size of 45x45x45 mm and a Ge slab facing the crystal's upper side) in the Cu frame, allowing for a modular construction of a large-scale array. Two designs are released: the initial $Thick$ version contains around 15% of Cu over the crystal mass (lithium molybdate, LMO), while this ratio is reduced to ~6% in a finer ($Slim$) design. Both designs were tested extensively at aboveground (IJCLab, France) and underground (LSC, Spain) laboratories. In particular, at LSC we used a pulse-tube-based CROSS facility to operate a 6-crystal array of LMOs enriched/depleted in $^{100}$Mo. The tested LMOs show high spectrometric performance in both designs; notably, the measured energy resolution is 5--7 keV FWHM at 2615 keV $γ$s, nearby the Q-value of $^{100}$Mo (3034 keV). Due to the absence of a reflective cavity around LMOs, a low scintillation signal is detected by Ge bolometers: ~0.3 keV (150 photons) for 1-MeV $γ$($β$) LMO-event. Despite that, an acceptable separation between $α$ and $γ$($β$) events is achieved with most devices. The highest efficiency is reached with light detectors in the $Thick$ design thanks to a lower baseline noise width (0.05--0.09 keV RMS) when compared to that obtained in the $Slim$ version (0.10--0.35 keV RMS). Given the pivotal role of bolometric photodetectors for particle identification and random coincidences rejection, we will use the structure here described with upgraded light detectors, featuring thermal signal amplification via the Neganov-Trofimov-Luke effect, as also demonstrated in the present work.

physics.ins-det

BINGO innovative assembly for background reduction in bolometric $0νββ$ experiments

BINGO is a project aiming to set the grounds for large-scale bolometric neutrinoless double-beta-decay experiments capable of investigating the effective Majorana neutrino mass at a few meV level. It focuses on developing innovative technologies (a detector assembly, cryogenic photodetectors and active veto) to achieve a very low background index, of the order of $10^{-5}$ counts/(keV kg yr) in the region of interest. The BINGO demonstrator, called MINI-BINGO, is designed to investigate the promising double-beta-decay isotopes $^{100}$Mo and $^{130}$Te and it will be composed of Li$_2$MoO$_4$ and TeO$_2$ crystals coupled to bolometric light detectors and surrounded by a Bi$_4$Ge$_3$O$_{12}$-based veto. This will allow us to reject a significant background in bolometers caused by surface contamination from $α$-active radionuclides by means of light yield selection and to mitigate other sources of background, such as surface contamination from $β$-active radionuclides, external $γ$ radioactivity, and pile-up due to random coincidence of background events. This paper describes an R\&D program towards the BINGO goals, particularly focusing on the development of an innovative assembly designed to reduce the passive materials within the line of sight of the detectors, which is expected to be a dominant source of background in next-generation bolometric experiments. We present the performance of two prototype modules -- housing four cubic (4.5-cm side) Li$_2$MoO$_4$ crystals in total -- operated in the Canfranc underground laboratory in Spain within a facility developed for the CROSS double-beta-decay experiment.

physics.ins-det

Results from a Prototype TES Detector for the Ricochet Experiment

Coherent elastic neutrino-nucleus scattering (CE$ν$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$ν$NS spectrum induced by the high neutrino flux from the Institut Laue-Langevin nuclear reactor. The experiment will employ an array of detectors, each with a mass of $\sim$30 g and a targeted energy threshold of 50 eV. Nine of these detectors (the "Q-Array") will be based on a novel Transition-Edge Sensor (TES) readout style, in which the TES devices are thermally coupled to the absorber using a gold wire bond. We present initial characterization of a Q-Array-style detector using a 1 gram silicon absorber, obtaining a baseline root-mean-square resolution of less than 40 eV.

physics.ins-det

Modeling terahertz emissions from energetic electrons and ions in foil targets irradiated by ultraintense femtosecond laser pulses

Terahertz (THz) emissions from fast electron and ion currents driven in relativistic, femtosecond laser-foil interactions are examined theoretically. We first consider the radiation from the energetic electrons exiting the backside of the target. Our kinetic model takes account of the coherent transition radiation due to these electrons crossing the plasma-vacuum interface as well as of the synchrotron radiation due to their deflection and deceleration in the sheath field they set up in vacuum. After showing that both mechanisms tend to largely compensate each other when all the electrons are pulled back into the target, we investigate the scaling of the net radiation with the sheath field strength. We then demonstrate the sensitivity of this radiation to a percent-level fraction of escaping electrons. We also study the influence of the target thickness and laser focusing. The same sheath field that confines most of the fast electrons around the target rapidly sets into motion the surface ions. We describe the THz emission from these accelerated ions and their accompanying hot electrons by means of a plasma expansion model that allows for finite foil size and multidimensional effects. Again, we explore the dependencies of this radiation mechanism on the laser-target parameters. Under conditions typical of current ultrashort laser-solid experiments, we find that the THz radiation from the expanding plasma is much less energetic -- by one to three orders of magnitude -- than that due to the early-time motion of the fast electrons.

physics.plasm-ph

Measuring the CMB primordial B-modes with Bolometric Interferometry

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of Δν/ν \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.

astro-ph.CO

All-optical attoclock for imaging tunnelling wavepackets

Recent experiments on measuring time-delays during tunnelling of cold atoms through an optically created potential barrier are reinvigorating the controversial debate regarding possible time-delays during light-induced tunnelling of an electron from an atom. Compelling theoretical and experimental arguments have been put forward to advocate opposite views, confirming or refuting the existence of finite tunnelling time delays. Yet, such a delay, whether present or not, is but a single quantity characterizing the tunnelling wavepacket; the underlying dynamics are richer. Here we propose to augment photo-electron detection in laser-induced tunnelling with detection of light emitted by the tunnelling electron -- the so-called Brunel radiation. Using a combination of single-color and two-color driving fields, we identify the all-optical signatures of the re-shaping of the tunnelling wavepacket as it emerges from the tunnelling barrier and moves away from the core. This reshaping includes not only an effective time-delay but also time-reversal asymmetry of the ionization process, which we describe theoretically and observe experimentally. We show how both delay and reshaping are mapped on the polarization properties of the Brunel radiation, with different harmonics behaving as different hands of a clock moving at different speeds. The all-optical detection paves the way to time-resolving optical tunnelling in condensed matter systems, e.g. tunnelling across bandgaps in solids, on the attosecond time-scale.

physics.optics

Test of $^{116}$CdWO$_4$ and Li$_2$MoO$_4$ scintillating bolometers in the CROSS underground facility with upgraded detector suspension

In preparation to the CROSS $2β$ decay experiment, we installed a new detector suspension with magnetic dumping inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two scintillating bolometers based on large-volume 116CdWO4 (CWO-enr) and Li2MoO4 (LMO) crystals. The former, a reference device, was used for testing new noise conditions and for comparing bolometric performance of an advanced Li2MoO4 crystal developed in the framework of the CLYMENE project, in view of next-generation double-beta decay experiments like CUPID. We cooled down detectors to 15 mK and achieved high performance for all tested devices. In particular both CWO-enr and LMO bolometers demonstrated the energy resolution of 6 keV FWHM for the 2.6 MeV gamma quanta, among the best for thermal detectors based on such compounds. The baseline noise resolution (FWHM) of the CWO-enr detector was improved by 2 keV, compared to the best previous measurement of this detector in the CROSS facility, while the noise of the Ge-based optical bolometer was improved by a factor 2, to 100 eV FWHM. Despite of the evident progress in the improving of noise conditions of the set-up, we see high-frequency harmonics of a pulse-tube induced noise, suggesting a noise pick-up by cabling. Another Ge light detector was assisted with the signal amplification exploiting the Neganov-Trofimov-Luke effect, which allowed to reach 20 eV FWHM noise resolution by applying 60 V electrode bias. Highly-efficient particle identification was achieved with both detectors, despite a low scintillation efficiency of the LMO material. The radiopurity level of the LMO crystal is rather high; only traces of 210Po and 226Ra were detected (0.1 mBq/kg each), while the 228Th activity is expected to be at least an order of magnitude lower, as well as a 40K activity is found to be < 6 mBq/kg.

physics.ins-det

First demonstration of 30 eVee ionization energy resolution with Ricochet germanium cryogenic bolometers

The future Ricochet experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the Ricochet collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30~eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar heat-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector. Additionally, we discuss the implications of these results in the context of the future Ricochet experiment and its expected background mitigation performance.

astro-ph.IM