Searcharxiv⌕ Search

arXiv subjects

L. Dumoulin

Publications and source records attributed to L. Dumoulin.

At least 37 records · Page 2Linked to original sources

Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.

physics.ins-det↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.

physics.ins-det↗

Enhanced light signal for the suppression of pile-up events in Mo-based bolometers for the $0νββ$ decay search

Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of $^{100}$Mo with macro-bolometers, due to their modest time resolution. Scintillating bolometers as those based on Li$_2$MoO$_4$ crystals and employed in the CROSS and CUPID experiments can eventually exploit the coincident fast signal detected in a light detector to reduce this background. However, the scintillation provides a modest signal-to-noise ratio, making difficult a pile-up pulse-shape recognition and rejection at timescales shorter than a few ms. Neganov-Trofimov-Luke assisted light detectors (NTL-LDs) offer the possibility to effectively increase the signal-to-noise ratio, preserving a fast time-response, and enhance the capability of pile-up rejection via pulse shape analysis. In this article we present: a) an experimental work performed with a Li$_2$MoO$_4$ scintillating bolometer, studied in the framework of the CROSS experiment, and utilizing a NTL-LD; b) a simulation method to reproduce, synthetically, randomly coincident two-neutrino double-beta decay events; c) a new analysis method based on a pulse-shape discrimination algorithm capable of providing high pile-up rejection efficiencies. We finally show how the NTL-LDs offer a balanced solution between performance and complexity to reach background index $\sim$$10^{-4}$ counts/keV/kg/year with 280~g Li$_2$MoO$_4$ ($^{100}$Mo enriched) bolometers at 3034 keV, the Q-value of the double-beta decay, and target the goal of a next generation experiment like CUPID.

physics.ins-det↗

Tagging and localisation of ionizing events using NbSi transition edge phonon sensors for Dark Matter searches

In the context of direct searches of sub-GeV Dark Matter particles with germanium detectors, the EDELWEISS collaboration has tested a new technique to tag ionizing events using NbSi transition edge athermal phonon sensors. The emission of the athermal phonons generated by the Neganov-Trofimov-Luke effect associated with the drift of electrons and holes through the detectors is used to tag ionization events generated in specific parts of the detector localized in front of the NbSi sensor and to reject by more than a factor 5 (at 90% C.L.) the background from heat-only events that dominates the spectrum above 3 keV. This method is able to improve by a factor 2.8 the previous limit on spin-independent interactions of 1 GeV/c2 WIMPs obtained with the same detector and data set but without this tagging technique.

physics.ins-det↗

Final results on the $0νββ$ decay half-life limit of $^{100}$Mo from the CUPID-Mo experiment

The CUPID-Mo experiment to search for 0$νββ$ decay in $^{100}$Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0$νββ$ decay experiment. CUPID-Mo was comprised of 20 enriched Li$_2$$^{100}$MoO$_4$ scintillating calorimeters, each with a mass of $\sim$ 0.2 kg, operated at $\sim$20 mK. We present here the final analysis with the full exposure of CUPID-Mo ($^{100}$Mo exposure of 1.47 kg$\times$yr) used to search for lepton number violation via 0$νββ$ decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $^{100}$Mo 0$νββ$ decay half-life of $T^{0ν}_{1/2} > 1.8 \times 10^{24}$ year (stat.+syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $\left < (0.28$--$0.49)$ eV, dependent upon the nuclear matrix element utilized.

nucl-ex↗

Search for sub-GeV Dark Matter via Migdal effect with an EDELWEISS germanium detector with NbSi TES sensors

The EDELWEISS collaboration reports on the search for Dark Matter (DM) particle interactions via Migdal effect with masses between $32$ MeV$\cdot$c$^{-2}$ to $2$ GeV$\cdot$c$^{-2}$ using a $200$ g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a Transition Edge Sensor made of a NbSi thin film. The detector was biased at $66$ V in order to benefit from the Neganov-Trofimov-Luke amplification and resulting in a resolution on the energy of electron recoils of $4.46$ eV$_{ee}$ (RMS) and an analysis threshold of $30$ eV$_{ee}$. The sensitivity is limited by a dominant background not associated to charge creation in the detector. The search constrains a new region of parameter space for cross-sections down to $10^{-29}$ cm$^2$ and masses between $32$ and $100$ MeV$\cdot$c$^{-2}$. The achieved low threshold with the NbSi sensor shows the relevance of its use for athermal-phonon sensitive devices for low-mass DM searches.

astro-ph.GA↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 meters away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment's shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $^3$He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance.

astro-ph.IM↗

New measurement of double beta decays of $^{100}$Mo to excited states of $^{100}$Ru with the CUPID-Mo experiment

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li$_2^{100}$MoO$_4$ (LMO) calorimeters each equipped with a Ge light detector (LD) for particle identification. In this work, we present the result of a search for two-neutrino and neutrinoless double beta decays of $^{100}$Mo to the first 0$^+$ and $2^+$ excited states of $^{100}$Ru using the full CUPID-Mo exposure (2.71 kg$\times$yr of LMO). We measure the half-life of $2νββ$ decay to the $0^{+}_1$ state as $T_{1/2}^{2ν\rightarrow 0_1^+}=7.5\pm 0.8 \ \text{(stat.)} \ ^{+ 0.4}_{-0.3} \ \text{(syst.)} )\times 10^{20} \ \mathrm{yr}$. The bolometric technique enables measurement of the electron energies as well as the gamma rays from nuclear de-excitation and this allows us to set new limits on the two-neutrino decay to the $2_1^+$ state of $T^{2ν\rightarrow 2_1^+}_{1/2}>4.4\times 10^{21} \ \mathrm{yr} \ \text{(90 % c.i.)}$ and on the neutrinoless modes of $T_{1/2}^{0ν\rightarrow 2_1^+}>2.1\times10^{23} \ \mathrm{yr}\ \text{(90 % c.i.)}$, $T_{1/2}^{0ν\rightarrow 0_1^+}>1.2\times10^{23} \ \mathrm{yr}\ \text{(90 % c.i.)}$. Information on the electrons spectral shape is obtained which allows us to make the first comparison of the single state (SSD) and higher state (HSD) $2νββ$ decay models for the $0_1^+$ excited state of $^{100}$Ru.

nucl-ex↗

Determining $g_{A}/g_{V}$ with High Resolution Spectral Measurements Using an LiInSe$_2$ Bolometer

Neutrinoless Double-Beta decay (0$νββ$) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant ($g_A/g_V$), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0$νββ$ experiments. In this Letter, we present measurements performed on a high-resolution LiInSe$_{2}$~ bolometer in a ''source=detector'' configuration to measure the spectral shape of the 4-fold forbidden $β$-decay of $^{115}$In. The value of $g_A/g_V$ is determined by comparing the spectral shape of theoretical predictions to the experimental $β$ spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of $g_A/g_V$ at $>5σ$ with a model-dependent quenching factor of $0.655\pm0.002$ as compared to the free-nucleon value for the Interacting Shell Model. We also measured the $^{115}$In half-life to be [$5.18\pm0.06(\text{stat.})^{+0.005}_{-0.015}(\text{sys.})]\times{10}^{14}$ yr within the Interacting Shell Model framework. This work demonstrates the power of the bolometeric technique to perform precision nuclear physics single-$β$ decay measurements, which can help reduce the uncertainties in the calculation of $0νββ$ nuclear matrix elements.

nucl-ex↗

First cryogenic tests on BINGO innovations

Neutrinoless double-beta decay ($0\nu2β$) is a hypothetical rare nuclear transition. Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating that the lepton number is not conserved. BINGO (Bi-Isotope $0\nu2β$ Next Generation Observatory) aims to set the technological grounds for future bolometric $0\nu2β$ experiments. It is based on a dual heat-light readout, i.e. a main scintillating absorber embedding the double-beta decay isotope accompanied by a cryogenic light detector. BINGO will study two of the most promising isotopes: $^{100}$Mo embedded in Li$_2$MoO$_4$ (LMO) crystals and $^{130}$Te embedded in TeO$_2$. BINGO technology will reduce dramatically the background in the region of interest, thus boosting the discovery sensitivity of $0\nu2β$. The proposed solutions will have a high impact on next-generation bolometric tonne-scale experiments, like CUPID. In this contribution, we present the results obtained during the first tests performed in the framework of BINGO R&D.

physics.ins-det↗

Toward CUPID-1T

Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$. We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.

nucl-ex↗

QUBIC VII: The feedhorn-switch system of the technological demonstrator

We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.

astro-ph.IM↗

QUBIC II: Spectro-Polarimetry with Bolometric Interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

astro-ph.IM↗

QUBIC III: Laboratory Characterization

A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.

astro-ph.IM↗

Coherent elastic neutrino-nucleus scattering: Terrestrial and astrophysical applications

Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a process in which neutrinos scatter on a nucleus which acts as a single particle. Though the total cross section is large by neutrino standards, CE$ν$NS has long proven difficult to detect, since the deposited energy into the nucleus is $\sim$ keV. In 2017, the COHERENT collaboration announced the detection of CE$ν$NS using a stopped-pion source with CsI detectors, followed up the detection of CE$ν$NS using an Ar target. The detection of CE$ν$NS has spawned a flurry of activities in high-energy physics, inspiring new constraints on beyond the Standard Model (BSM) physics, and new experimental methods. The CE$ν$NS process has important implications for not only high-energy physics, but also astrophysics, nuclear physics, and beyond. This whitepaper discusses the scientific importance of CE$ν$NS, highlighting how present experiments such as COHERENT are informing theory, and also how future experiments will provide a wealth of information across the aforementioned fields of physics.

hep-ph↗

Low-mass Dark Matter searches with EDELWEISS

The EDELWEISS collaboration searches for light Dark Matter (DM) particles using germanium detectors equipped with a charge and phonon signal readout. Using the Neganov-Trofimov-Luke effect, an rms resolution of 0.53 electron-hole pair was obtained on a massive (33.4 g) Ge detector operated underground at the Laboratoire Souterrain de Modane. This record sensitivity made possible a search for Dark Photon DM down to 1 eV/c2 and to DM-electron interactions below 1 MeV/c2. This demonstrates for the first time the high relevance of cryogenic Ge detectors in searches at low thresholds and is an important step of the development of Ge detectors with improved performance in the context of the EDELWEISS-SubGeV program.

physics.ins-det↗

First germanium-based constraints on sub-MeV Dark Matter with the EDELWEISS experiment

The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$ DM particles interacting with electrons, as well as on dark photons down to 1 eV/c$^2$. These are competitive with other searches. In particular, new limits are set on the kinetic mixing of dark photon DM in a so far unconstrained parameter space region in the 6 to 9 eV/c$^2$ mass range. These results demonstrate the high relevance of cryogenic Ge detectors for the search of DM interactions producing eV-scale electron signals.

astro-ph.GA↗

EXCESS workshop: Descriptions of rising low-energy spectra

Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.

astro-ph.IM↗