SearcharxivSearch

arXiv subjects

L. M. Pant

Publications and source records attributed to L. M. Pant.

At least 19 recordsLinked to original sources

Study of neutron response using time of flight technique in ISMRAN detector

We report the measurements of the fast neutron energy response in Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector consisting of an array of 9$\times$10 Plastic Scintillator Bars (PSBs) at BARC, Mumbai. ISMRAN is an above ground detector setup at $\sim$13 m from the Dhruva reactor core for the detection of reactor anti-neutrinos (${\overline{\ensuremathν}}_{e}$) via the inverse beta decay (IBD) process. The dominant sources of reactor-related background in the vicinity of the detector are high energy $γ$-rays and fast neutrons. Therefore, a good understanding of fast neutron response in PSB is an essential pre-requisite for suppression and discrimination of the fast neutron background from IBD events. Kinetic energies of the fast neutron were determined using the Time-of-Flight (TOF) technique, which is used to get the scintillation light yield due to recoiling proton in PSB. We also measured the fast neutron capture time distribution in ISMRAN array using a novel technique involving TOF of the measured fast neutrons. The observed characteristic neutron capture time ( $τ$ ) of 68.29 $\pm$ 9.48 $μ$s is in good agreement with GEANT4 based MC simulation. These experimentally measured results will be useful for discriminating correlated and uncorrelated (accidental) background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.

physics.ins-det

Measurement of cosmic muon-induced neutron background with ISMRAN detector in a non-reactor environment

The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremathν}}_{e}$) experiment, located inside the Dhruva research reactor facility, Mumbai, India. The primary goal of the ISMRAN experiment is the indirect detection of reactor ${\overline{\ensuremathν}}_{e}$ through an inverse beta decay (IBD) process, using a cluster of 90 optically segmented plastic scintillator detectors, weighing $\sim$1 ton. In this work, we present the neutron capture time response and energy deposition of neutron capture signals generated by cosmic muons in the ISMRAN geometry, and we compare these experimental results with Geant4-based Monte Carlo (MC) simulations. The obtained mean capture time of fast neutrons is 74.46 $\pm$ 5.98 $\mathrmμ$s and is comparable with the MC simulation results. The efficiency-corrected rate of muon-induced neutron background inside the ISMRAN geometry, due to the presence of a passive shielding structure of 10 cm lead followed by 10 cm borated polyethylene with a surface area of 600 $\mathrm{cm^{2}}$, deployed on top of the ISMRAN setup, is reported to be 1334 $\pm$ 64 (stat.) $\pm$ 70 (sys.) per day. This result shows good agreement with the expected background rate from MC simulations using Geant4. We also estimate the muon-induced fast-neutron rate in the ISMRAN geometry for the actual shielding configuration of 9000 $\mathrm{cm^{2}}$ surface area to be 3335 $\pm$ 160 (stat.) $\pm$ 175 (sys.) neutrons $\mathrm{day^{-1}}$ through an extrapolation, after incorporating the model dependent acceptance correction factor from the Geant4 MC simulation. Finally, using these results, we evaluate the neutron production yield due to the composite shielding in the ISMRAN geometry, which is 2.81$\times$$\mathrm{10^{-5}}$ neutrons per $μ$ per (g/$\mathrm{cm^{2}}$) at sea level.

physics.ins-det

Background measurements and detector response studies for ISMRAN experiment

We report the measurement of the non-reactor environmental backgrounds and the detector response with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), which is $\sim$1 ton detector setup by volume, consisting of 10$\times$9 (10 rows and 9 columns) Plastic Scintillator Bars (PSBs) array at BARC, Mumbai, India. ISMRAN is an above-ground anti-neutrino ($\mathrm{\overlineν_{e}}$) experiment at very short baseline located at Dhruva research reactor facility. It is enclosed by a shielding made of 10 cm thick lead and 10 cm thick borated polyethylene to minimize the backgrounds and is mounted on a movable base structure, situated at $\sim$ 13 m away from the reactor core. These measurements are useful in the context of the ISMRAN detector setup that will be used to detect the reactor $\mathrm{\overlineν_{e}}$ and measure its energy spectrum through the inverse beta decay (IBD) process. In this paper, we present the energy resolution model and energy non-linearity model of PSB and the cosmogenic muon-induced background, based on the sum of their energy depositions and number of hit bars. Reconstructed sum energy spectrum and number of hit bars distribution for $\mathrm{{}^{22}Na}$ radioactive source has been compared with Geant4 based Monte Carlo simulations. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.

physics.ins-det

Evaluation of the response of plastic scintillator bars and measurement of neutron capture time in non-reactor environment for the ISMRAN experiment

We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector setup consisting of 9$\times$10 Plastic Scintillator Bars (PSBs) array at BARC, Mumbai. These measurements are useful in the context of the ISMRAN detector setup, which will be used to detect the reactor anti-neutrinos (${\bar{\ensuremathν}}_{e}$) and measure its energy spectra, through the inverse beta decay (IBD) process. A GEANT4 based Monte Carlo (MC) simulation is used to understand the optical transmission, energy resolution and energy non-linearity of the ISMRAN detector. A detailed analysis procedure has been developed to understand the natural radioactive, cosmogenic and cosmic muon-induced backgrounds with the ISMRAN detector setup in a non-reactor environment, based on their energy deposition, number of bars hit as well as topological event selection criteria in position and time for triggered events. Data and MC simulated distributions of reconstructed sum energy and number of bars hit has been compared for the radioactive $γ$ + positron source such as $\mathrm{{}^{22}Na}$ placed at the center of the ISMRAN array. Fast neutron energy response and capture time distribution in ISMRAN array has been studied using a novel technique involving Time of Flight (TOF) of the measured fast neutrons. The observed characteristic neutron capture time ( $τ$ ) of 68.29 $\pm$ 9.48 $μ$s is in good agreement with $\sim$65 $μ$s obtained from MC simulation. These experimentally measured results will be useful for discriminating the correlated and uncorrelated background events from the true IBD events in reactor ON and OFF conditions inside the reactor hall.

physics.ins-det

Cosmic ray measurements using the ISMRAN setup in a non-reactor environment

The cosmic rays data collected using a large area plastic scintillator array ISMRAN (Indian Scintillator Matrix for Reactor AntiNeutrino) are presented. The data collected serve as a useful benchmark of cosmogenic background in a non-reactor environment for the future measurements of electron-antineutrinos to be performed using the ISMRAN setup. The zenith angle distribution of the atmospheric muons has been measured and compared with Monte Carlo expectations. The detector setup was further used to measure the lifetime distribution of stopped muons and extract their rates inside the detector matrix. The measured spectra of decaying muons and associated electrons show a good agreement with the MC simulations performed through GEANT4 simulation.

nucl-ex

Measurements using a prototype array of plastic scintillator bars for reactor based electron anti-neutrino detection

We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embedding technique is used to estimate the efficiencies from a data driven background study. The obtained anti-neutrino like events in RON condition are 218 $\pm$ 50 (stat) $\pm$ 37 (sys) after background subtraction. The obtained results are compared with theoretical estimation which yields 214 $\pm$ 32 (sys) anti-neutrino events for the RON condition.

nucl-ex

Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions

We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.

physics.ins-det

Active-sterile neutrino mixing constraint using reactor antineutrinos with the ISMRAN set-up

In this work, we present an analysis of the sensitivity to the active-sterile neutrino mixing with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up at very short baseline. In this article, we have considered the measurement of electron antineutrino induced events employing a single detector which can be placed either at a single position or moved between near and far positions from the given reactor core. Results extracted in the later case are independent of the theoretical prediction of the reactor anti-neutrino spectrum and detector related systematic uncertainties. Our analysis shows that the results obtained from the measurement carried out at a combination of the near and far detector positions are improved significantly at higher $Δm^{2}_{41}$ compared to the ones obtained with the measurement at a single detector position only. It is found that the best possible combination of near and far detector positions from a 100 MW$_{th}$ power DHRUVA research reactor core are 7 m and 9 m, respectively, for which ISMRAN set-up can exclude in the range 1.4 $eV^{2} \leq Δm^{2}_{41} \leq$ 4.0 $eV^{2}$ of reactor antineutrino anomaly region along with the present best-fit point of active-sterile neutrino oscillation parameters. At those combinations of detector positions, the ISMRAN set-up can observe the active sterile neutrino oscillation with a 95$\%$ confidence level provided that $\sin^{2}2θ_{14}\geq 0.09$ at $Δm^{2}_{41}$ = 1 eV$^{2}$ for an exposure of 1 ton-yr. The active-sterile neutrino mixing sensitivity can be improved by about 22\% at the same exposure by placing the detector at near and far distances of 15 m and 17 m, respectively, from the compact proto-type fast breeder reactor (PFBR) facility which has a higher thermal power of 1250 MW$_{th}$.

hep-ph

Machine learning technique to improve anti-neutrino detection efficiency for the ISMRAN experiment

The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and delayed neutron from IBD will provide the signature of $\barν_e$ event in ISMRAN. The number of segments with energy deposit ($\mathrm{N_{bars}}$) and sum total of these deposited energies are used as discriminants for identifying prompt positron event and delayed neutron capture event. However, a simple cut based selection of above variables leads to a low $\barν_e$ signal detection efficiency due to overlapping region of $\mathrm{N_{bars}}$ and sum energy for the prompt and delayed events. Multivariate analysis (MVA) tools, employing variables suitably tuned for discrimination, can be useful in such scenarios. In this work we report the results from an application of artificial neural network -- the multilayer perceptron (MLP), particularly the Bayesian extension -- MLPBNN, to the simulated signal and background events in ISMRAN. The results from application of MLP to classify prompt positron events from delayed neutron capture events on Hydrogen, Gadolinium nuclei and also from the typical reactor $γ$-ray and fast neutron backgrounds is reported. An enhanced efficiency of $\sim$91$\%$ with a background rejection of $\sim$73$\%$ for prompt selection and an efficiency of $\sim$89$\%$ with a background rejection of $\sim$71$\%$ for the delayed capture event, is achieved using the MLPBNN classifier for the ISMRAN experiment.

physics.data-an

Sensitivity to sterile neutrino mixing using reactor antineutrinos

The reactor antineutrinos are used for the precise measurement of oscillation parameters in the 3-neutrino model, and also used to investigate active-sterile neutrino mixing sensitivity in the 3$+$1 neutrino framework. In the present work, we study the feasibility of sterile neutrino search with the Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) experimental set-up using electron antineutrinos ($\overlineν_e$) produced from reactor as a source. The so-called 3$+$1 scenario is considered for active-sterile neutrino mixing, which leads to projected exclusion curves in the sterile neutrino mass and mixing angle plane. The analysis is performed considering both the reactor and detector related parameters. It is found that, the ISMRAN set-up can observe the active-sterile neutrino mixing sensitivity for $\sin^{2}2θ_{14} \geq$ 0.064 and $Δm^{2}_{41}$ = 1.0 eV$^2$ at 90$\%$ confidence level for an exposure of 1 ton-year by using neutrinos produced from the DHRUVA reactor with thermal power of 100 MW$_{th}$. It is also observed that, there is a significant improvement of the active-sterile neutrino mixing parameter $\sin^{2}2θ_{14}$ to $\sim$ 0.03 at the same $Δm^{2}_{41}$ by putting the ISMRAN detector set-up at a distance of 20 m from the compact proto-type fast breeder reactor (PFBR) facility with thermal power of 1250 MW$_{th}$.

hep-ph

A plastic scintillator array for reactor based anti-neutrino studies

Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN), a plastic scintillator array (10$\times$10), is being constructed for the purpose of electron anti-neutrino ($\overline\nuup_{e}$) detection for reactor monitoring applications. A prototype detector called mini-ISMRAN, which consists of 16$\%$ of ISMRAN, has been setup for studying the detector response, background rates and event characterization in the reactor and non-reactor environment. The data acquisition system based on waveform digitizers is being used for pulse processing and event triggering. Monte-Carlo based simulations using GEANT4 are performed to optimize lead (Pb) and borated polyethylene (BP) shielding for background reduction and to study the positron, neutron and $γ$-ray response in the ISMRAN detector. Characterization of plastic scintillator detectors with known radioactive sources is done for energy, timing and position measurements. Using the energy summation and bar multiplicity selection, coincident events from $\mathrm{{}^{60}Co}$ decay are reconstructed in non-reactor environment. Results from background measurements using various detectors are quantified in reactor ON and OFF condition. The shielding of 10 cm Pb and 10 cm BP along with the requirement of hits in multiple bars, reduces the uncorrelated background in reactor ON condition.

physics.ins-det

High Rate RPC detector for LHC

The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\ {\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.

physics.ins-det

Experimental results on charge fluctuations in heavy-ion collisions

We present a subset of experimental results on charge fluctuation from the heavy-ion collisions to search for phase transition and location of critical point in the QCD phase diagram. Measurements from the heavy-ion experiments at the SPS and RHIC energies observe that total charge fluctuations increase from central to peripheral collisions. The net-charge fluctuations in terms of dynamical fluctuation measure $ν_{(+-,dyn)}$ are studied as a function of collision energy (\sqsn) and centrality of the collisions. The product of $ν_{(+-,dyn)}$ and $\langle N_{ch} \rangle$ shows a monotonic decrease with collision energies, which indicates that at LHC energy the fluctuations have their origin in the QGP phase. The fluctuations in terms of higher moments of net-proton, net-electric charge and net-kaon have been measured for various \sqsn. Deviations are observed in both $Sσ$ and $κσ^2$ for net-proton multiplicity distributions from the Skellam and hadron resonance gas model for \sqsn $<$ 39 GeV. Higher moment results of the net-electric charge and net-kaon do not observe any significant non-monotonic behavior as a function of collision energy. We also discuss the extraction of the freeze-out parameters using particle ratios and experimentally measured higher moments of net-charge fluctuations. The extracted freeze-out parameters from experimentally measured moments and lattice calculations, are found to be in agreement with the results obtained from the fit of particle ratios to the thermal model calculations.

nucl-ex

R&D towards the CMS RPC Phase-2 upgrade

The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.

physics.ins-det

Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.

physics.ins-det

Photoproduction of ω Mesons off the Proton

The differential cross sections and unpolarized spin-density matrix elements for the reaction $γp\to pω$ were measured using the CBELSA/TAPS experiment for initial photon energies ranging from the reaction threshold to 2.5 GeV. These observables were measured from the radiative decay of the $ω$ meson, $ω\toπ^0γ$. The cross sections cover the full angular range and show the full extent of the $t$-channel forward rise. The overall shape of the angular distributions in the differential cross sections and unpolarized spin-density matrix elements are in fair agreement with previous data. In addition, for the first time, a beam of linearly-polarized tagged photons in the energy range from 1150 MeV to 1650 MeV was used to extract polarized spin-density matrix elements. These data were included in the Bonn-Gatchina partial wave analysis (PWA). The dominant contribution to $ω$ photoproduction near threshold was found to be the $3/2^+$ partial wave, which is primarily due to the sub-threshold $N(1720)\,3/2^+$ resonance. At higher energies, pomeron-exchange was found to dominate whereas $π$-exchange remained small. These $t$-channel contributions as well as further contributions from nucleon resonances were necessary to describe the entire dataset: the $1/2^-$, $3/2^-$, and $5/2^+$ partial waves were also found to contribute significantly.

nucl-ex

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.

physics.ins-det

Transparency ratio in γA -> η' A' and the in-medium η' width

The photoproduction of η'-mesons off different nuclei has been measured with the CBELSA/TAPS detector system for incident photon energies between 1500 - 2200 MeV. The transparency ratio has been deduced and compared to theoretical calculations describing the propagation of η'-mesons in nuclei. The comparison indicates a width of the η' -meson of the order of Γ= 15-25 MeV at ρ=ρ_0 for an average momentum p_{η'} = 1050 MeV/c, at which the η'-meson is produced in the nuclear rest frame. The inelastic η' N cross section is estimated to be 3 - 10 mb. Parameterizing the photoproduction cross section of η'-mesons by σ(A) = σ_0 A^α, a value of α= 0.84\pm0.03 has been deduced.

nucl-ex