Abstract

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $\mu$rad pitch arranged in eight $\eta$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $\mu$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $\mu$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $\mu$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $\mu$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $\mu$rad. Other $\eta$-sectors of the detector show similar response and performance.

Explore related subjects

Keep this discovery

BibTeXRIS

D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo, C. Calabria, M. Caponero, C. Caputo, F. Cassese, A. Castaneda, S. Cauwenbergh, F. R. Cavallo, A. Celik, M. Choi, K. Choi, S. Choi, J. Christiansen, A. Cimmino, S. Colafranceschi, A. Colaleo, A. Conde Garcia, M. M. Dabrowski, G. De Lentdecker, R. De Oliveira, G. de Robertis, S. Dildick, B. Dorney, W. Elmetenawee, G. Fabrice, M. Ferrini, S. Ferry, P. Giacomelli, J. Gilmore, L. Guiducci, A. Gutierrez, R. M. Hadjiiska, A. Hassan, J. Hauser, K. Hoepfner, M. Hohlmann, H. Hoorani, Y. G. Jeng, T. Kamon, P. E. Karchin, H. S. Kim, S. Krutelyov, A. Kumar, J. Lee, T. Lenzi, L. Litov, F. Loddo, T. Maerschalk, G. Magazzu, M. Maggi, Y. Maghrbi, A. Magnani, N. Majumdar, P. K. Mal, K. Mandal, A. Marchioro, A. Marinov, J. A. Merlin, A. K. Mohanty, A. Mohapatra, S. Muhammad, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, E. Oliveri, L. M. Pant, P. Paolucci, I. Park, G. Passeggio, B. Pavlov, B. Philipps, M. Phipps, D. Piccolo, H. Postema, G. Pugliese, A. Puig Baranac, A. Radi. 2014-11-30. Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System. https://arxiv.org/abs/1412.0228

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det