SearcharxivSearch

arXiv subjects

L. Moleri

Publications and source records attributed to L. Moleri.

18 recordsLinked to original sources

Development of a Multi-Purpose Optical TPC for Neutron-Induced Reaction Studies at SARAF

Neutron-induced reactions play a central role in stellar and Big Bang nucleosynthesis models. Yet many of the cross sections remain poorly constrained at astrophysically relevant energies. To address these needs, we are developing a multi-purpose Optical Time Projection Chamber (OTPC) optimized for precision neutron-reaction studies at the Soreq Applied Research Accelerator Facility (SARAF) upcoming high-intensity, time-of-flight neutron beam. The detector combines a drift chamber filled with CF4-based scintillating gas mixtures, fast photodetectors for prompt scintillation detection, and high-speed optical readout of avalanche-induced secondary scintillation to enable full 3D reconstruction of charged-particle tracks. A prototype system has been assembled and tested. This has enabled systematic characterization of electron drift velocity, charge and light amplification, and 2D optical imaging of alpha-particle tracks in an Ar/CF4 gas mixture. These studies guide the design of a larger, fully integrated OTPC system intended for operation at SARAF. In parallel, we are exploring advanced image sensors to further enhance tracking resolution. We report on recent progress with the prototype and outline the next steps toward commissioning the full system.

physics.ins-det

Performance of resistive MPGDs with pad readout coupled to VMM3a ASIC

We present a comparative study of three resistive Micro-Pattern Gaseous Detector (MPGD) technologies - Micromegas, RPWELL, and $\mu\mathrm{-RWELL}$ - with VMM3a based readout, using relativistic muons and pions. The Micromegas and the RPWELL were operated in $\mathrm{Ar/CO_2/iC_4H_{10}}$ gas mixture, while the $\mu\mathrm{-RWELL}$ in $\mathrm{Ar/CO_2/CF_4}$ (greenhouse gas containing mixture). All detectors operated stably exceeding 96% efficiency. The usage of continuous readout enabled studies of detector electrical instabilities in- and off-beam at near breakdown voltages. Each technology has different advantages making it more suitable for various experimental conditions.

physics.ins-det

Cryogenic RPWELL: a novel charge-readout element for dual-phase argon TPCs

The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode via Fe$_2$O$_3$/YSZ ceramics (Fe$_2$O$_3$ in weight equal to 75$\%$), with tunable bulk resistivity in the range 10$^{9}$ - 10$^{12}$ $\Omega\cdot$cm. The detector was operated at liquid argon temperature in saturated argon vapor (90~K, 1.2~bar) and characterized in terms of its effective charge gain and stability against discharges. Maximum stable gain of G$\approx$17 was obtained, without discharges. In addition, preliminary results from novel 3D-printed thermoplastic plates doped with carbon nanotubes are presented.

physics.ins-det

The cryogenic RWELL: a stable charge multiplier for dual-phase liquid-argon detectors

The operation of a cryogenic Resistive WELL (RWELL) in liquid argon vapor is reported for the first time. It comprises a Thick Gas Electron Multiplier (THGEM) structure coupled to a resistive Diamond-Like Carbon (DLC) anode deposited on an insulating substrate. The multiplier was operated at cryogenic temperature (90~K, 1.2~bar) in saturated argon vapor and characterized in terms of charge gain and electrical stability. A comparative study with standard, non-resistive THGEM (a.k.a LEM) and WELL multipliers, confirmed the RWELL advantages in terms of discharge quenching - thus superior gain and stability.

physics.ins-det

Development of Fe$_2$O$_3$/YSZ ceramic plates for cryogenic operation of resistive-protected gaseous detectors

We present a ceramic material based on hematite (Fe$_2$O$_3$) and zirconia stabilized with yttria at 8% molar (YSZ), that exhibits stable electrical properties with transported charge and that can be tuned to the resistivities necessary to induce spark-quenching in gaseous detectors ($\rho = 10^9-10^{12}$ $\Omega \cdot$cm), from room temperature down to the liquid-vapor coexistence point of nitrogen (77 K). It, thus, allows covering the operating temperatures of most immediate interest to gaseous instrumentation. The ceramics have been produced in a region of mass concentrations far from what has been usually explored in literature: optimal characteristics are achieved for Fe$_2$O$_3$ concentrations of 75%wt (LAr boiling temperature), 35%wt (LXe boiling temperature), and 100%wt (room temperature). The nine order of magnitude enhancement observed for the electrical conductivity of the mixed phases relative to that of pure Fe$_2$O$_3$ is startling, however it can be qualitatively understood based on existing literature. Plates of 4 cm x 4 cm have been manufactured and, prior to this work, operated in-detector at the LXe boiling point (165 K), demonstrating spark-free operation. Preliminary results obtained for the first time on a spark-protected amplification structure (RP-WELL) at around the LAr boiling point (90 K) are now presented, too.

physics.ins-det

Towards a large-area RPWELL detector: design optimization and performance

We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved performances compared to previous ones: MIP detection efficiency over 96\% with 3\% uniformity across the entire detector area, a charge gain of $\mathrm{\approx{7.5 \times 10^3}}$ with a uniformity of 22\%, and discharge probability below $\mathrm{10^{-6}}$ with a few single hotspots attributed to production imperfections. These results pave the way towards further up-scaling detectors of this kind.

physics.ins-det

Novel resistive charge-multipliers for dual-phase LAr-TPCs: towards stable operation at higher gains

Cryogenic versions of Resistive WELL (RWELL) and Resistive Plate WELL (RPWELL) detectors have been developed, aimed at stable avalanche multiplication of ionization electrons in dual-phase TPCs. In the RWELL, a thin resistive layer deposited on top of an insulator is inserted in between the electron multiplier (THGEM) and the readout anode; in the RPWELL, a resistive plate is directly coupled to the THGEM. Radiation-induced ionization electrons in the liquid are extracted into the gaseous phase. They drift into the THGEM's holes where they undergo charge multiplication. Embedding resistive materials into the multiplier proved to enhance operation stability due to the mitigation of electrical discharges - thus allowing operation at higher charge gain compared to standard THGEM (a.k.a. LEM) multipliers. We present the detector concepts and report on the main preliminary results.

physics.ins-det

The New Small Wheel electronics

The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the "small" Thin Gap Chambers, with a total of 2.45 Million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm$^{2}$ at the expected HL-LHC luminosity of $\mathcal{L}$=7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.

hep-ex

Bubble dynamics in Liquid Hole Multipliers

In bubble-assisted Liquid HoleMultipliers(LHM), developed for noble-liquid radiation detectors, the stability of the bubble and the electro-mechanical properties of the liquid-to-gas interface play a dominant role in the detector performance. A model is proposed to evaluate the static equilibrium configurations of a bubble sustained underneath a perforated electrode immersed in a liquid. For the first time bubbles were optically observed in LAr; their properties were studied in contact with different material surfaces. This permitted investigating the bubble-electrodynamics via numerical simulations; it was shown that the electric field acts as an additional pressure term on the bubble meniscus. The predictions for the liquid-to-gas interface were successfully validated using X-ray micro-CT in water and in silicone oil at STP. The proposed model and the results of this study are an important milestone towards understanding and optimizing the parameters of LHM-based noble-liquid detectors.

physics.ins-det

In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector

In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.

physics.ins-det

The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector

A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.

physics.ins-det

First in-beam studies of a Resistive-Plate WELL gaseous multiplier

We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.

physics.ins-det

Optical readout: a tool for studying gas-avalanche processes

Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4 (95/5). We present the results of direct measurements, with single- and cascaded-THGEM detectors irradiated with soft x-rays, of the hole-multiplicity and avalanche asymmetry within holes, as a function of detector parameters. Further study directions are discussed.

physics.ins-det

A concept for laboratory studies of radiation detectors over a broad dynamic-range: instabilities evaluation in THGEM-structures

A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge probability. The methodology, applicable to a broad range of detectors, is applied here for instability studies in various single-stage THGEM and THGEM-WELL structures. The results indicate upon a somewhat larger attainable dynamic range in a single-stage THGEM operated with additional multiplication in the induction gap.

physics.ins-det

Laboratory studies of THGEM-based WELL structures with resistive anodes

In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-quenching capability, gain variation with position and counting rate, pulse shapes and signal propagation to neighboring readout pads; the study included both 30x30 and 100x100 mm$^2$ detectors. It was shown that the WELL structures with resistive anodes offer stable operation even in a highly ionizing environment, with effective spark quenching, as well as higher gain than the standard THGEM/induction-gap configuration. Cross talk between neighboring readout pads was shown to be effectively eliminated in the segmented detector with a conductive grid underneath the resistive layer. The latter multiplier should allow for the design of very thin detectors, e.g. sampling elements in digital hadronic calorimeters planned for experiments in future linear colliders.

physics.ins-det

Recent advances with THGEM detectors

The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are single-sided THGEM electrodes directly coupled to different anode readout electrodes. The structures differ by the coupling concept of the bottom THGEM electrode to the metallic readout pads: a Thick WELL (THWELL) with direct coupling; the Resistive WELL (RWELL) and the Segmented Resistive WELL (SRWELL) coupled through thin resistive films deposited on insulating sheets and a Resistive-Plate WELL (RPWELL) coupled through a plate of high bulk resistivity. The results are compared to that of traditional double-sided THGEM electrodes followed by induction gaps - in some cases with moderate additional multiplication within the gap. We compare the different configurations in terms of gain, avalanche extension, discharge-rate and magnitude as well as rate capabilities over a broad dynamic range - exploiting a method that mimics highly ionizing particles in the laboratory. We report on recent studies of avalanche distribution in THGEM holes using optical readout.

physics.ins-det

First studies with the Resistive-Plate WELL gaseous multiplier

We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV x-ray in Ne/5%CH4; a minor 30% gain drop occurred with a rate increase from 10 to 10^4 Hz/mm^2. The detector displayed a full "discharge-free" operation--even when exposed to high primary ionization events. We present the RPWELL detector concept and compare its performance to that of other previously explored THGEM configurations--in terms of gain, its curves, dependence on rate, and the response to high ionization. The robust Resistive Plate WELL concept is a step forward in the Micro-Pattern Gas-Detector family, with numerous potential applications.

physics.ins-det

Beam studies of novel THGEM-based potential sampling elements for Digital Hadron Calorimetry

Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a resistive layer to APV-SRS readout electronics, were investigated with muons and pions. Detection efficiencies in the 98% range were recorded with an average pad-multiplicity of ~1.1. The resistive anode resulted in efficient discharge damping, with few-volt potential drops; discharge probabilities were ~10^{-7} for muons and 10^{-6} for pions in the double-stage configuration, at rates of a few kHz/cm^2. These results, together with the robustness of THGEM electrodes against spark damage and their suitability for economic production over large areas make THGEM-based detectors highly competitive compared to the other technologies considered for the SiD-DHCAL.

physics.ins-det