L. S. Kuzmin

Publications and source records attributed to L. S. Kuzmin.

6 recordsLinked to original sources

Observation of thermal microwave photons with a Josephson junction detector

When measuring electromagnetic radiation of frequency $f$, the most sensitive detector is the one that counts the single quanta of energy $h f$. Single photon detectors (SPDs) were demonstrated from $γ$-rays to infrared wavelengths, and extending this range down to the microwaves is the focus of intense research. The energy of $10\,\mathrm{GHz}$ microwave photon, about $40\,\mathrm{μeV}$ or $7\, \mathrm{yJ},$ is enough to force a superconducting Josephson junction into its resistive state, making it suitable to be used as a sensor. In this work, we use an underdamped Josephson junction to detect single thermal photons stochastically emitted by a microwave copper cavity at millikelvin temperatures. After characterizing the source and detector, we vary the temperature of the resonant cavity and measure the increased photon rate. The device shows an efficiency up to 40% and a dark count rate of $0.1\,\mathrm{Hz}$ in a bandwidth of several gigahertz. To confirm the thermal nature of the emitted photons we verify their super-Poissonian statistics, which is also a signature of quantum chaos. We discuss detector application in the scope of Dark Matter Axion searches, and note its importance for quantum information, metrology and fundamental physics.

quant-ph

Cold-electron bolometer, as a 1 cm wavelength photon counter

We investigate theoretically the possibility of using the cold-electron bolometer (CEB) as a counter for 1 cm wavelength (30 GHz) photons. To reduce the flux of photons from the environment, which interact with the detector, the bath temperature is assumed to be below 50 mK. At such temperatures, the time interval between two subsequent photons of 30 GHz that hit the detector is more than 100 hours, on average, for a frequency window of 1 MHz. Such temperatures allow the observation of the physically significant photons produced in rare events, like the axions conversion (or Primakoff conversion) in magnetic field. We present the general formalism for the detector's response and noise, together with numerical calculations for proper experimental setups. We observe that the current-biased regime is favorable, due to lower noise, and allows for the photons counting at least below 50 mK. For the experimental setups investigated here, the voltage-biased CEBs may also work as photons counters, but with less accuracy and eventually at bath temperatures below 40 mK. The voltage-biased setups also require smaller volumes of the normal metal island of the detector.

cond-mat.mes-hall

Electromagnetic radiation detectors based on Josephson junctions: Effective Hamiltonian

We theoretically analyze two setups of low energy single-photon counters based on Josephson junctions (JJ). For this, we propose two simple and general models, based on the macroscopic quantum tunneling formalism (MQT). The first setup is similar to the photon counter based on the "cold electron bolometer" (CEB), where the JJ replaces the CEB in the center of the superconducting antenna. In the second setup, the JJ is capacitively coupled to the antenna. We derive the Hamiltonians for the two setups and we write the Schrödinger equations taking into account both, the antenna and the JJ. The quantum particles of the MQT models are in two-dimensional potential landscapes, which are parabolic along one direction and may have the form of a washboard potential along another direction. Such a potential landscape has a series of local minima, separated by saddle points. If the particle is prepared in the initial state in the metastable "ground state" of a local minimum, then the photon absorption causes it to jump into an excited state. If the excitation energy is bigger than the potential barrier seen by the quantum particle (the difference between the "ground state" and the saddle point), the photon is detected. The models are simple and allow us to do mostly analytical calculations. We show that the two setups are equivalent form the MQT point of view, since one Hamiltonian can be transformed into the other by changes of variables. For typical values of the JJ and antenna parameters, the setups may work as counters of photons of wavelengths up to 1 cm, at least.

cond-mat.mes-hall

Observation of photon noise by cold-electron bolometers

We have measured a response to a black body radiation and noise of the cold-electron bolometers. The experimental results have been fitted by theoretical model with two heat-balance equations. The measured noise has been decomposed into several terms with the help of theory. It is demonstrated that the photon noise exceeds any other noise components, that allows us to conclude that the bolometers see the photon noise. Moreover, a peculiar shape of the noise dependence on the absorbed power originates completely from the photonic component according to the theory. In the additional experiment on heating of the cryostat plate together with the sample holder we have observed nearly independence of the noise on the electron temperature of the absorber, which has provided another proof of the presence of the photon noise in the first experiment.

physics.ins-det

Quasioptical qualification of parallel/series arrays of cold-electron bolometers with a cross-slot antenna

We perform experimental and theoretical study of the parallel-series arrays of Cold-Electron Bolometers (CEBs) integrated into a cross-slot antenna and composed with an immersion silicon lens. The purpose is to determine the absorption efficiency, the responsivity and the noise equivalent power (NEP) of the bolometers. The absorbed power has been found in two independent ways. The comparison of two approaches gives better understanding of the system and secures from misinterpretations. The first approach is fitting of the bolometer IV curves with solutions of heat-balance equations. The second approach is modeling of electromagnetic properties of the system, including an antenna, lens, optical can, band-pass filters and black body source. The difference between both methods does not exceed $30\%$. The optimization of experimental setup is proposed to approach the photon limited detection mode.

physics.ins-det

Strong Tunneling and Coulomb Blockade in a Single-Electron Transistor

We have developed a detailed experimental study of a single-electron transistor in a strong tunneling regime. Although weakened by strong charge fluctuations, Coulomb effects were found to persist in all samples including one with the effective conductance 8 times higher than the quantum value (6.45 k$Ω$)$^{-1}$. A good agreement between our experimental data and theoretical results for the strong tunneling limit is found. A reliable operation of transistors with conductances 3-4 times larger than the quantum value is demonstrated.

cond-mat