Publications and source records attributed to L. Servoli.

12 recordsLinked to original sources

Toward High-Resolution Detection of Target Fragmentation: TEA-Sensitized NIT for Proton Therapy Applications

Nano Imaging Trackers (NIT) are fine-grained nuclear emulsions capable of tracking charged particles with sub-micrometric spatial resolution. The DAMON (Direct Measurement of Target Fragmentation) experiment recently employed NIT to detect target-fragmentation events relevant to proton therapy in direct kinematics. These measurements showed that the small crystal size, while providing high spatial resolution, limits the reconstruction efficiency for primary proton tracks and high-energy secondary protons. This work reports an enhancement of NIT sensitivity achieved through alternative chemical sensitization methods, namely gold-plus-sulfur (Au-S) and triethanolamine (TEA), together with the use of the GR-1 developer. The detector response was evaluated with gamma-ray, carbon-ion and proton exposures, including clinically relevant proton energies.

physics.ins-det

New method for clustering thresholds determination in Microstrip Silicon Detector

The Microstrip Silicon Detector (MSD) is one of the subsystems of the FragmentatiOn Of Target (FOOT) experiment whose goal is to measure double differential nuclear fragmentation cross sections for applications in particle therapy and radioprotection in space. The MSD, composed of six 150 $\mu$m-thick silicon sensors arranged in three X-Y measuring planes, is part of the FOOT experiment tracking region. In this work, we propose a new method to set the MSD thresholds for the clustering algorithm independently of the other detectors of the experiment. The obtained values can be used as reference values from which to perform a threshold scan in order to evaluate the single-ion detection efficiency of each MSD sensor and to orient the clustering analysis using tracking information.}

physics.ins-det

HASPIDE-SPACE: a new concept of a radiation-resistant instrument for solar energetic particles

Galactic cosmic rays and solar energetic particles (SEPs) affect the performance of instruments carried on board space missions and are the source of the absorbed dose to astronauts. Particles above 100 MeV are the most penetrating. The overall particle flux impacting spacecraft increases by several orders of magnitude during the most intense SEP events and gamma-ray bursts, compared to the galactic cosmic-ray background. Unfortunately, most detectors dedicated to the monitoring of solar particles in space do not allow measurements above 200 MeV. Space agencies and the space and heliospheric weather communities are interested in improving this scenario. We propose a new, compact, low-power, and radiation-resistant instrument, intended for long-duration missions to monitor solar X-rays, electrons, and protons up to energies of tens of keV, MeV, and 600 MeV, respectively. Intense long and short gamma-ray bursts would be observed in the absence of solar activity.

hep-ex

Cross Section Measurements of Large Angle Fragments Production in the Interaction of Carbon Ion Beams with Thin Targets

The fragmentation cross sections of carbon ion beams with kinetic energies of $115 - 353~\text{MeV/u}$ impinging on thin targets of graphite (C), polyvinyl-toluene (C$_9$H$_{10}$) and PMMA (C$_2$O$_5$H$_8$) have been measured at 90$^{\text{o}}$ and 60$^{\text{o}}$ at the CNAO particle therapy center (Pavia, Italy). The presented measurements are a complete reanalysis by the FOOT collaboration of already published elemental cross section on composite targets, in order to refine the analysis, improve the systematic uncertainties and show the comparison with the FLUKA Monte Carlo code calculations. In this work, the kinetic energy at production of measured fragments has been completely redefined, together with the efficiencies computation. The new analysis strategy has been successfully validated against the Monte Carlo cross sections. Two detection arms were positioned at two different angles to perform the measurement at 90$^{\text{o}}$ and 60$^{\text{o}}$. The fragment species have been identified in charge (Z$_{id}$ = H) and mass (M$_{id}$ = $^1$H, $^2$H, $^3$H) combining the information of the deposited energy in thin plastic scintillators, of the deposited energy in a thick LYSO crystal and of the fragments Time of Flight (ToF) measurement. The ToF was also used to compute the fragments measured kinetic energy. The cross sections are presented as a function of the fragments kinetic energy at production thanks to an unfolding technique applied to the data.

nucl-ex

Angular differential and elemental fragmentation cross sections of a $400\,\text{MeV/nucleon}$ $^{16}\text{O}$ beam on a graphite target with the FOOT experiment

This paper presents the measurements of the angular differential cross sections for the forward production of He, Li, Be, B, C and N nuclei in the fragmentation process of a 400$\text{MeV/nucleon}$ $^{16}\text{O}$ beam interacting with a graphite target. Due to the limited data available in this energy regime, these measurements of nuclear fragmentation cross sections are relevant to improve nuclear interaction models for Particle Therapy and space radioprotection applications. The data analyzed in this paper were collected during a measurement campaign carried out at the GSI Helmholtz Center for Heavy Ion Research facility in Darmstadt (Germany) by the FOOT collaboration. The results are compared with similar results found in the literature and with a previous FOOT measurement of the same process, using the same setup, from a previous pilot run performed at GSI. The pilot run data, however, had limited statistics and only allowed for the measurement of elemental fragmentation cross sections integrated in the setup acceptance. This data set, with statistics more than 100 times larger compared to the data collected in the previous run, enabled the measurement of angular differential cross sections, fully exploiting the granularity of the FOOT $\Delta \text{E}$-TOF system. Furthermore, a better comprehension of the FOOT apparatus allowed to improve the analysis techniques, leading to a reduction in the final systematic uncertainties.

nucl-ex

Proton irradiation on Hydrogenated Amorphous Silicon flexible devices

Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two different configurations and thicknesses. The first device was a 2 um thick n-i-p diode having a 5 mm x 5 mm area. The second device was a 5 um thick charge selective contact detector having the same area. Both the devices were deposited on a flexible polyimide substrate and were irradiated up to the fluence of 1016 neq/cm2. The response to different proton fluxes has been measured before irradiation and after irradiation at 1016 neq/cm2 for charge-selective contacts and n-i-p devices. The effect of annealing for partial performance recovery at 100{\deg}C for 12 hours was also studied and a final characterization on annealed devices was performed. This test is the first combined displacement and total ionizing dose test on flexible a-Si:H devices.

physics.ins-det

Characterization of hydrogenated amorphous silicon sensors on polyimide flexible substrate

Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H sensors can be successfully utilized in dosimetry, beam monitoring for particle physics (x-ray, electron, gamma-ray and proton detection) and radiotherapy, radiation flux measurement for space applications (study of solar energetic particles and stellar events) and neutron flux measurements. In this paper we have studied the dosimetric x-ray response of n-i-p diodes deposited on Polyimide. We measured the linearity of the photocurrent response to x-rays versus dose-rate from which we have extracted the dosimetric x-ray sensitivity at various bias voltages. In particular low bias voltage operation has been studied to assess the high energy efficiency of these kind of sensor. A measurement of stability of x-ray response versus time has been shown. The effect of detectors annealing has been studied. Operation under bending at various bending radii is also shown.

physics.ins-det

Development of thin hydrogenated amorphous silicon detectors on a flexible substrate

The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (mostly Polyimide) for beam monitoring, neutron detection and space applications. Since a-Si:H is a material with superior radiation hardness, the benefit for the above-mentioned applications can be appreciated mostly in radiation harsh environments. Furthermore, the possibility to deposit this material on flexible substrates like Polyimide (PI), polyethylene naphthalate (PEN) or polyethylene terephthalate (PET) facilitates the usage of these detectors in medical dosimetry, beam flux and beam profile measurements. Particularly interesting is its use when positioned directly on the flange of the vacuum-to-air separation interface in a beam line, as well as other applications where a thin self-standing radiation flux detector is envisaged. In this paper, the HASPIDE project will be described and some preliminary results on PI and glass substrates will be reported.

physics.ins-det

Testing of planar hydrogenated amorphous silicon sensors with charge selective contacts for the construction of 3D- detectors

Hydrogenated Amorphous Silicon (a-Si:H) is a material well known for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and dosimetry. Planar p-i-n diode detectors are fabricated entirely by means of intrinsic and doped PECVD of a mixture of Silane (SiH4) and molecular Hydrogen. In order to develop 3D detector geometries using a-Si:H, two options for the junction fabrication have been considered: ion implantation and charge selective contacts through atomic layer deposition. In order to test the functionality of the charge selective contact electrodes, planar detectors have been fabricated utilizing this technique. In this paper, we provide a general overview of the 3D fabrication project followed by the results of leakage current measurements and x-ray dosimetric tests performed on planar diodes containing charge selective contacts to investigate the feasibility of the charge selective contact methodology for integration with the proposed 3D detector architectures.

physics.ins-det

Recent Results from Polycrystalline CVD Diamond Detectors

Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse height versus particle rate of unirradiated and irradiated polycrystalline CVD (pCVD) diamond pad detectors up to a particle flux of $20\,\mathrm{MHz/cm^2}$ and a fluence up to $4 \times 10^{15}\,n/\mathrm{cm^2}$.

physics.ins-det

Measurements and TCAD Simulations of Bulk and Surface Radiation Damage Effects in Silicon Detectors

In this work we propose the application of a radiation damage model based on the introduction of deep level traps/recombination centers suitable for device level numerical simulation of radiation detectors at very high fluences (e.g. 1÷2 10^16 1-MeV equivalent neutrons per square centimeter) combined with a surface damage model developed by using experimental parameters extracted from measurements from gamma irradiated p-type dedicated test structures.

physics.ins-det

Full Geant4 and FLUKA Simulations of an e-LINAC for its Use in Particle Detectors Performance Tests

In this work we present the results of full Geant4 and FLUKA simulations and comparison with dosimetry data of an electron LINAC of St. Maria Hospital located in Terni, Italy. The facility is being used primarily for radiotherapy and the goal of present study is the detailed investigation of electron beam parameters to evaluate the possibility to use the e-LINAC (during time slots when it is not used for radiotherapy) to test the performance of detector systems in particular those designed to operate in space. The critical beam parameters are electron energy, profile and flux available at the surface of device to be tested. The present work aims to extract these parameters from dosimetry calibration data available at the e-LINAC. The electron energy ranges is from 4 MeV to 20 MeV. The dose measurements have been performed by using an Advanced Markus Chamber which has a small sensitive volume.

physics.ins-det