Searcharxiv⌕ Search

arXiv subjects

Laura Baudis

Publications and source records attributed to Laura Baudis.

At least 37 records · Page 2Linked to original sources

Characterisation of Silicon Photomultipliers for Liquid Xenon Detectors

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the vacuum ultraviolet scintillation light from LXe at 178$\,$nm with high resolution and detection efficiency and low noise rates. Further requirements for dark matter and double beta decay searches are ultra-low radioactivity levels of all the components including the substrates and cold electronics. Here we describe our characterisation of Hamamatsu 6$\times$6$\,$mm$^2$ SiPMs in the temperature range 110-300$\,$K in nitrogen gas, as well as long-term measurements in cold nitrogen gas at 172$\,$K and liquid xenon at 185$\,$K. After we introduce the experimental setups, the data acquisition schemes and analysis methods, we show the single-photon response, the gain versus bias voltage, as well as the dark and correlated noise rates. We demonstrate the long-term stability at cryogenic temperatures, and conclude that SiPM arrays are promising candidates for photosensor arrays in liquid xenon detectors. Furthermore, we study the radioactivity of the raw SiPM materials with gamma spectrometry and inductively coupled plasma mass spectrometry and conclude that SiPMs are suitable for use in low-background experiments.

physics.ins-det↗

The Search for Dark Matter

The dark matter problem is almost a century old. Since the 1930s evidence has been growing that our cosmos is dominated by a new form of non-baryonic matter, that holds galaxies and clusters together and influences cosmic structures up to the largest observed scales. At the microscopic level, we still do not know the composition of this dark, or invisible matter, which does not interact directly with light. The simplest assumption is that it is made of new particles that interact with gravity and at most weakly with known elementary particles. I will discuss searches for such new particles, both space- and Earth-bound including those placed in deep underground laboratories. While a dark matter particle hasn't been yet identified, even after decades of concerted efforts, new technological developments and experiments have reached sensitivities where a discovery might be imminent, albeit certainly not guaranteed.

astro-ph.CO↗

A Dual-phase Xenon TPC for Scintillation and Ionisation Yield Measurements in Liquid Xenon

A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in liquid xenon at energies below 50 keV, which are relevant for rare event searches using xenon as target material. Here we describe in detail the detector, its associated infrastructure, and the signal identification algorithm developed for processing and analysing the data. We present the first characterisation of the new instrument with calibration data from an internal 83m-Kr source. The zero-field light yield is 15.0 and 14.0 photoelectrons/keV at 9.4 keV and 32.1 keV, respectively, and the corresponding values at an electron drift field of 1 kV/cm are 10.8 and 7.9 photoelectrons/keV. The charge yields at these energies are 28 and 31 electrons/keV, with the proportional scintillation yield of 24 photoelectrons per one electron extracted into the gas phase, and an electron lifetime of 200 $μ$s. The relative energy resolution, $σ/E$, is 11.9 % and 5.8 % at 9.4 keV and 32.1 keV, respectively using a linear combination of the scintillation and ionisation signals. We conclude with measurements of the electron drift velocity at various electric fields, and compare these to literature values.

astro-ph.IM↗

Cosmogenic activation of xenon and copper

Rare event search experiments using liquid xenon as target and detection medium require ultra-low background levels to fully exploit their physics potential. Cosmic ray induced activation of the detector components and, even more importantly, of the xenon itself during production, transportation and storage at the Earth's surface, might result in the production of radioactive isotopes with long half-lives, with a possible impact on the expected background. We present the first dedicated study on the cosmogenic activation of xenon after 345 days of exposure to cosmic rays at the Jungfraujoch research station at 3470m above sea level, complemented by a study of copper which has been activated simultaneously. We have directly observed the production of 7Be, 101Rh, 125Sb, 126I and 127Xe in xenon, out of which only 125Sb could potentially lead to background for a multi-ton scale dark matter search. The production rates for five out of eight studied radioactive isotopes in copper are in agreement with the only existing dedicated activation measurement, while we observe lower rates for the remaining ones. The specific saturation activities for both samples are also compared to predictions obtained with commonly used software packages, where we observe some underpredictions, especially for xenon activation.

astro-ph.IM↗

Dark matter sensitivity of multi-ton liquid xenon detectors

We study the sensitivity of multi ton-scale time projection chambers using a liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent and spin-dependent WIMP-nucleon scattering interactions. Taking into account realistic backgrounds from the detector itself as well as from neutrinos, we examine the impact of exposure, energy threshold, background rejection efficiency and energy resolution on the dark matter sensitivity. With an exposure of 200 t x y and assuming detector parameters which have been already demonstrated experimentally, spin-independent cross sections as low as $2.5 \times 10^{-49}$ cm$^2$ can be probed for WIMP masses around 40 GeV/$c^2$. Additional improvements in terms of background rejection and exposure will further increase the sensitivity, while the ultimate WIMP science reach will be limited by neutrinos scattering coherently off the xenon nuclei.

physics.ins-det↗

Dark matter searches

One of the major challenges of modern physics is to decipher the nature of dark matter. Astrophysical observations provide ample evidence for the existence of an invisible and dominant mass component in the observable universe, from the scales of galaxies up to the largest cosmological scales. The dark matter could be made of new, yet undiscovered elementary particles, with allowed masses and interaction strengths with normal matter spanning an enormous range. Axions, produced non-thermally in the early universe, and weakly interacting massive particles (WIMPs), which froze out of thermal equilibrium with a relic density matching the observations, represent two well-motivated, generic classes of dark matter candidates. Dark matter axions could be detected by exploiting their predicted coupling to two photons, where the highest sensitivity is reached by experiments using a microwave cavity permeated by a strong magnetic field. WIMPs could be directly observed via scatters off atomic nuclei in underground, ultra low-background detectors, or indirectly, via secondary radiation produced when they pair annihilate. They could also be generated at particle colliders such as the LHC, where associated particles produced in the same process are to be detected. After a brief motivation and an introduction to the phenomenology of particle dark matter detection, I will discuss the most promising experimental techniques to search for axions and WIMPs, addressing their current and future science reach, as well as their complementarity.

astro-ph.CO↗

Production and Characterization of 228Th Calibration Sources with Low Neutron Emission for GERDA

The GERDA experiment at the Laboratori Nazionali del Gran Sasso (LNGS) searches for the neutrinoless double beta decay of 76-Ge. In view of the GERDA Phase II data collection, four new 228-Th radioactive sources for the calibration of the germanium detectors enriched in 76-Ge have been produced with a new technique, leading to a reduced neutron flux from ( alpha; n ) reactions. The gamma activities of the sources were determined with a total uncertainty of 4 percent using an ultra-low background HPGe detector operated underground at LNGS. The emitted neutron flux was determined using a low background LiI(Eu) detector and a 3-He counter at LNGS. In both cases, a reduction of about one order of magnitude with respect to commercially available 228-Th sources was obtained. Additionally, a specific leak test with a sensitivity to leaks down to 10 mBq was developed to investigate the tightness of the stainless steel capsules housing the sources after their use in cryogenic environment.

physics.ins-det↗

Enhancement of Light Yield and Stability of Radio-Pure Tetraphenyl-Butadiene Based Coatings for VUV Light Detection in Cryogenic Environments

The detection of VUV scintillation light, e.g. in (liquid) argon detectors, commonly includes a reflector with a fluorescent coating, converting UV photons to visible light. The light yield of these detectors depends directly on the conversion efficiency. Several coating/reflector combinations were produced using VM2000, a specular reflecting multi layer polymer, and Tetratex, a diffuse reflecting PTFE fabric, as reflector foils. The light yield of these coatings was optimised and has been measured in a dedicated liquid argon setup built at the University of Zurich. It employs a small, 1.3 kg LAr cell viewed by a 3-inch, low radioactivity PMT of type R11065-10 from Hamamatsu. The cryogenic stability of these coatings was additionally studied. The optimum reflector/coating combination was found to be Tetratex dip coated with Tetraphenyl-butadiene with a thickness of 0.9 mg/cm$^2$ resulting in a 3.6 times higher light yield compared to uncoated VM2000. Its performance was stable in long term measurements, ran up to 100 days, in liquid argon. This coated reflector was further investigated concerning radioactive impurities found to be suitable for current and upcoming low-background experiments. Therefore it is used for the liquid argon veto in Phase II of the GERDA neutrinoless double beta decay experiment.

physics.ins-det↗

WIMP Dark Matter Direct-Detection Searches in Noble Gases

Cosmological observations and the dynamics of the Milky Way provide ample evidence for an invisible and dominant mass component. This so-called dark matter could be made of new, colour and charge neutral particles, which were non-relativistic when they decoupled from ordinary matter in the early universe. Such weakly interacting massive particles (WIMPs) are predicted to have a non-zero coupling to baryons and could be detected via their collisions with atomic nuclei in ultra-low background, deep underground detectors. Among these, detectors based on liquefied noble gases have demonstrated tremendous discovery potential over the last decade. After briefly introducing the phenomenology of direct dark matter detection, I will review the main properties of liquefied argon and xenon as WIMP targets and discuss sources of background. I will then describe existing and planned argon and xenon detectors that employ the so-called single- and dual-phase detection techniques, addressing their complementarity and science reach.

astro-ph.IM↗

Dark Matter in the Coming Decade: Complementary Paths to Discovery and Beyond

In this Report we discuss the four complementary searches for the identity of dark matter: direct detection experiments that look for dark matter interacting in the lab, indirect detection experiments that connect lab signals to dark matter in our own and other galaxies, collider experiments that elucidate the particle properties of dark matter, and astrophysical probes sensitive to non-gravitational interactions of dark matter. The complementarity among the different dark matter searches is discussed qualitatively and illustrated quantitatively in several theoretical scenarios. Our primary conclusion is that the diversity of possible dark matter candidates requires a balanced program based on all four of those approaches.

hep-ph↗

Kaluza-Klein Dark Matter: Direct Detection vis-a-vis LHC (2013 update)

We present updated results on the complementarity between high-energy colliders and dark matter direct detection experiments in the context of Universal Extra Dimensions (UED). In models with relatively small mass splittings between the dark matter candidate and the rest of the (colored) spectrum, the collider sensitivity is diminished, but direct detection rates are enhanced. UED provide a natural framework to study such mass degeneracies. We discuss the detection prospects for the KK photon $γ_1$ and the KK $Z$-boson $Z_1$, combining the expected LHC reach with cosmological constraints from WMAP/Planck, and the sensitivity of current or planned direct detection experiments. Allowing for general mass splittings, neither colliders, nor direct detection experiments by themselves can explore all of the relevant KK dark matter parameter space. Nevertheless, they probe different parameter space regions, and the combination of the two types of constraints can be quite powerful.

hep-ph↗

Monte Carlo Studies and Optimization for the Calibration System of the GERDA Experiment

The GERmanium Detector Array, GERDA, searches for neutrinoless double beta decay in Ge-76 using bare high-purity germanium detectors submerged in liquid argon. For the calibration of these detectors gamma emitting sources have to be lowered from their parking position on top of the cryostat over more than five meters down to the germanium crystals. With the help of Monte Carlo simulations, the relevant parameters of the calibration system were determined. It was found that three Th-228 sources with an activity of 20 kBq each at two different vertical positions will be necessary to reach sufficient statistics in all detectors in less than four hours of calibration time. These sources will contribute to the background of the experiment with a total of (1.07 +/- 0.04(stat) +0.13 -0.19(sys)) 10^{-4} cts/(keV kg yr) when shielded from below with 6 cm of tantalum in the parking position.

physics.ins-det↗

Response of liquid xenon to Compton electrons down to 1.5 keV

The response of liquid xenon to low-energy electronic recoils is relevant in the search for dark-matter candidates which interact predominantly with atomic electrons in the medium, such as axions or axion-like particles, as opposed to weakly interacting massive particles which are predicted to scatter with atomic nuclei. Recently, liquid-xenon scintillation light has been observed from electronic recoils down to 2.1 keV, but without applied electric fields that are used in most xenon dark matter searches. Applied electric fields can reduce the scintillation yield by hindering the electron-ion recombination process that produces most of the scintillation photons. We present new results of liquid xenon's scintillation emission in response to electronic recoils as low as 1.5 keV, with and without an applied electric field. At zero field, a reduced scintillation output per unit deposited energy is observed below 10 keV, dropping to nearly 40% of its value at higher energies. With an applied electric field of 450 V/cm, we observe a reduction of the scintillation output to about 75% relative to the value at zero field. We see no significant energy dependence of this value between 1.5 keV and 7.8 keV. With these results, we estimate the electronic-recoil energy thresholds of ZEPLIN-III, XENON10, XENON100, and XMASS to be 2.8 keV, 2.5 keV, 2.3 keV, and 1.1 keV, respectively, validating their excellent sensitivity to low-energy electronic recoils.

astro-ph.IM↗

Performance of the Hamamatsu R11410 Photomultiplier Tube in cryogenic Xenon Environments

The Hamamatsu R11410 photomultiplier, a tube of 3" diameter and with a very low intrinsic radioactivity, is an interesting light sensor candidate for future experiments using liquid xenon (LXe) as target for direct dark matter searches. We have performed several experiments with the R11410 with the goal of testing its performance in environments similar to a dark matter detector setup. In particular, we examined its long-term behavior and stability in LXe and its response in various electric field configurations.

astro-ph.IM↗

Direct dark matter detection: the next decade

Direct dark matter searches are promising techniques to identify the nature of dark matter particles. I describe the future of this field of research, focussing on the question of what can be achieved in the next decade. I will present the main techniques and R&D projects that will allow to build so-called ultimate WIMP detectors, capable of probing spin-independent interactions down to the unimaginably low cross section of 1e-48 cm2, before the irreducible neutrino background takes over. If a discovery is within the reach of a near-future dark matter experiment, these detectors will be able to constrain WIMP properties such as its mass, scattering cross section and possibly spin. With input from the LHC and from indirect searches, direct detection experiments will hopefully allow to determine the local density and to constrain the local phase-space structure of our dark matter halo.

astro-ph.IM↗

Results from the XENON100 Dark Matter Search Experiment

XENON100 is a liquid xenon time projection chamber built to search for rare collisions of hypothetical, weakly interacting massive particles (WIMPs), which are candidates for the dark matter in our universe, with xenon atoms. Operated in a low-background shield at the Gran Sasso Underground Laboratory in Italy, XENON100 has reached the unprecedented background level of <0.15 events/(day keV) in the energy range below 100 keV in 30 kg of target mass, before electronic/nuclear recoil discrimination. It found no evidence for WIMPs during a dark matter run lasting for 100.9 live days in 2010, excluding with 90% confidence scalar WIMP-nucleon cross sections above 7e-45 cm2 at a WIMP mass of 50 GeV/c2. A new run started in March 2011, and more than 210 live days of WIMP-search data were acquired. Results are expected to be released in spring 2012. The construction of the ton-scale XENON1T detector in Hall B of the Gran Sasso Laboratory will start in late 2012.

astro-ph.IM↗

DARWIN: dark matter WIMP search with noble liquids

DARWIN (dark matter wimp search with noble liquids) is a design study for a next-generation, multi-ton dark matter detector in Europe. Liquid argon and/or liquid xenon are the target media for the direct detection of dark matter candidates in the form of weakly interacting massive particles (WIMPs). Light and charge signals created by particle interactions in the active detector volume are observed via the time projection chamber technique. DARWIN is to probe the spin-independent, WIMP-nucleon cross section down 1e-48 cm2 and to measure WIMP-induced nuclear recoil spectra with high-statistics, should they be discovered by an existing or near-future experiment. After a brief introduction, I will describe the project, selected R&D topics, expected backgrounds and the physics reach.

astro-ph.IM↗

Complementarity of Dark Matter Direct Detection Targets

We investigate the reconstruction capabilities of Dark Matter mass and spin-independent cross-section from future ton-scale direct detection experiments using germanium, xenon or argon as targets. Adopting realistic values for the exposure, energy threshold and resolution of Dark Matter experiments which will come online within 5 to 10 years, the degree of complementarity between different targets is quantified. We investigate how the uncertainty in the astrophysical parameters controlling the local Dark Matter density and velocity distribution affects the reconstruction. For a 50 GeV WIMP, astrophysical uncertainties degrade the accuracy in the mass reconstruction by up to a factor of $\sim 4$ for xenon and germanium, compared to the case when astrophysical quantities are fixed. However, combination of argon, germanium and xenon data increases the constraining power by a factor of $\sim 2$ compared to germanium or xenon alone. We show that future direct detection experiments can achieve self-calibration of some astrophysical parameters, and they will be able to constrain the WIMP mass with only very weak external astrophysical constraints.

astro-ph.CO↗