SearcharxivSearch

arXiv subjects

Liao Wu

Publications and source records attributed to Liao Wu.

17 recordsLinked to original sources

LightFARM: Model Predictive Lighting Control with Battery-Free IoT for Energy-Efficient Indoor Farming

Lighting is the dominant energy load in indoor farming, yet most deployed systems still rely on fixed rule-based or schedule-based control. We present LightFARM, a predictive lighting control framework that couples crop illumination with battery-free sensing for more energy-efficient indoor farming. LightFARM combines finite-horizon predictive control with compact models of photosynthesis, thermal dynamics, and sensor energy state. The controller adjusts lighting intensity to balance photosynthetic benefit, electrical power consumption, thermal safety, and sensing-energy feasibility. A key design feature is that the same light-emitting diode (LED) fixtures serve both as the photosynthetic light source for crops and as a controllable energy source for self-powered sensor nodes. We implement LightFARM in a real indoor basil cultivation system and evaluate it through two independent 12-day cultivation trials. Compared with a conventional rule-based baseline, LightFARM reduces lighting energy consumption by approximately 41% and improves energy productivity from 36.1 to 52.9 $\mathrm{g\,kWh^{-1}}$ and from 41.1 to 60.2 $\mathrm{g\,kWh^{-1}}$ ($\approx 46.5\%$ on average). These results suggest that energy-cooperative predictive lighting control is a promising approach to improving indoor farming efficiency under practical resource constraints, while explicitly accounting for the trade-off between energy savings and crop yield.

eess.SP

Reinforcement Learning for Follow-the-Leader Robotic Endoscopic Navigation via Synthetic Data

Autonomous navigation is crucial for both medical and industrial endoscopic robots, enabling safe and efficient exploration of narrow tubular environments without continuous human intervention, where avoiding contact with the inner walls has been a longstanding challenge for prior approaches. We present a follow-the-leader endoscopic robot based on a flexible continuum structure designed to minimize contact between the endoscope body and intestinal walls, thereby reducing patient discomfort. To achieve this objective, we propose a vision-based deep reinforcement learning framework guided by monocular depth estimation. A realistic intestinal simulation environment was constructed in \textit{NVIDIA Omniverse} to train and evaluate autonomous navigation strategies. Furthermore, thousands of synthetic intraluminal images were generated using NVIDIA Replicator to fine-tune the Depth Anything model, enabling dense three-dimensional perception of the intestinal environment with a single monocular camera. Subsequently, we introduce a geometry-aware reward and penalty mechanism to enable accurate lumen tracking. Compared with the original Depth Anything model, our method improves $\delta_{1}$ depth accuracy by 39.2% and reduces the navigation J-index by 0.67 relative to the second-best method, demonstrating the robustness and effectiveness of the proposed approach.

cs.RO

Towards Closing the Domain Gap with Event Cameras

Although traditional cameras are the primary sensor for end-to-end driving, their performance suffers greatly when the conditions of the data they were trained on does not match the deployment environment, a problem known as the domain gap. In this work, we consider the day-night lighting difference domain gap. Instead of traditional cameras we propose event cameras as a potential alternative which can maintain performance across lighting condition domain gaps without requiring additional adjustments. Our results show that event cameras maintain more consistent performance across lighting conditions, exhibiting domain-shift penalties that are generally comparable to or smaller than grayscale frames and provide superior baseline performance in cross-domain scenarios.

cs.CV

A Wearable Strain-Sensor-Based Shoulder Patch for Fatigue Detection in Bicep Curls

A common challenge in home-based rehabilitation is muscle compensation induced by pain or fatigue, where patients with weakened primary muscles recruit secondary muscle groups to assist their movement, causing issues such as delayed rehabilitation progress or risk of further injury. In a home-based setting, the subtle compensatory actions may not be perceived since physiotherapists cannot directly observe patients. To address this problem, this study develops a novel wearable strain sensor-based shoulder patch to detect fatigue-induced muscle compensation during bicep curl exercises. Built on an observation that the amplitude of a strain sensor's resistance is correlated to the motion of a joint that the sensor is attached to, we develop an algorithm that can robustly detect the state when significant changes appear in the shoulder joint motion, which indicates fatigue-induced muscle compensation in bicep curls. The developed shoulder patch is tested on 13 subjects who perform bicep curl exercises with a 5 kg dumbbell until reaching fatigue. During the experiment, the performance of the shoulder patch is also benchmarked with optical tracking sensors and surface electromyography (sEMG) sensors. Results reveal that the proposed wearable sensor and detection methods effectively monitor fatigue-induced muscle compensation during bicep curl exercises in both Real-Time and Post Hoc modes. This development marks a significant step toward enhancing the effectiveness of home-based rehabilitation by providing physiotherapists with a tool to monitor and adjust treatment plans remotely.

eess.SP

JammingSnake: A follow-the-leader continuum robot with variable stiffness based on fiber jamming

Follow-the-leader (FTL) motion is essential for continuum robots operating in fragile and confined environments. It allows the robot to exert minimal force on its surroundings, reducing the risk of damage. This paper presents a novel design of a snake-like robot capable of achieving FTL motion by integrating fiber jamming modules (FJMs). The proposed robot can dynamically adjust its stiffness during propagation and interaction with the environment. An algorithm is developed to independently control the tendon and FJM insertion movements, allowing the robot to maintain its shape while minimizing the forces exerted on surrounding structures. To validate the proposed design, comparative tests were conducted between a traditional tendon-driven robot and the novel design under different configurations. The results demonstrate that our design relies significantly less on contact with the surroundings to maintain its shape. This highlights its potential for safer and more effective operations in delicate environments, such as minimally invasive surgery (MIS) or industrial in-situ inspection.

cs.RO

Automatic Tissue Traction Using Miniature Force-Sensing Forceps for Minimally Invasive Surgery

A common limitation of autonomous tissue manipulation in robotic minimally invasive surgery (MIS) is the absence of force sensing and control at the tool level. Recently, our team has developed miniature force-sensing forceps that can simultaneously measure the grasping and pulling forces during tissue manipulation. Based on this design, here we further present a method to automate tissue traction that comprises grasping and pulling stages. During this process, the grasping and pulling forces can be controlled either separately or simultaneously through force decoupling. The force controller is built upon a static model of tissue manipulation, considering the interaction between the force-sensing forceps and soft tissue. The efficacy of this force control approach is validated through a series of experiments comparing targeted, estimated, and actual reference forces. To verify the feasibility of the proposed method in surgical applications, various tissue resections are conducted on ex vivo tissues employing a dual-arm robotic setup. Finally, we discuss the benefits of multi-force control in tissue traction, evidenced through comparative analyses of various ex vivo tissue resections with and without the proposed method, and the potential generalization with traction on different tissues. The results affirm the feasibility of implementing automatic tissue traction using miniature forceps with multi-force control, suggesting its potential to promote autonomous MIS. A video demonstrating the experiments can be found at https://youtu.be/f5gXuXe67Ak.

cs.RO

Effects of fiber number and density on fiber jamming: Towards follow-the-leader deployment of a continuum robot

Fiber jamming modules (FJMs) offer flexibility and quick stiffness variation, making them suitable for follow-the-leader (FTL) motions in continuum robots, which is ideal for minimally invasive surgery (MIS). However, their potential has not been fully exploited, particularly in designing and manufacturing small-sized FJMs with high stiffness variation. Although existing research has focused on factors like fiber materials and geometry to maximize stiffness variation, the results often do not apply to FJMs for MIS due to size constraints. Meanwhile, other factors such as fiber number and packing density, less significant to large FJMs but critical to small-sized FJMs, have received insufficient investigation regarding their impact on the stiffness variation for FTL deployment. In this paper, we design and fabricate FJMs with a diameter of 4mm. Through theoretical and experimental analysis, we find that fiber number and packing density significantly affect both absolute stiffness and stiffness variation. Our experiments confirm the feasibility of using FJMs in a medical FTL robot design. The optimal configuration is a 4mm FJM with 0.4mm fibers at a 56% packing density, achieving up to 3400% stiffness variation. A video demonstration of a prototype robot using the suggested parameters for achieving FTL motions can be found at https://youtu.be/7pI5U0z7kcE.

cs.RO

Analysis of Fatigue-Induced Compensatory Movements in Bicep Curls: Gaining Insights for the Deployment of Wearable Sensors

A common challenge in Bicep Curls rehabilitation is muscle compensation, where patients adopt alternative movement patterns when the primary muscle group cannot act due to injury or fatigue, significantly decreasing the effectiveness of rehabilitation efforts. The problem is exacerbated by the growing trend toward transitioning from in-clinic to home-based rehabilitation, where constant monitoring and correction by physiotherapists are limited. Developing wearable sensors capable of detecting muscle compensation becomes crucial to address this challenge. This study aims to gain insights into the optimal deployment of wearable sensors through a comprehensive study of muscle compensation in Bicep Curls. We collect upper limb joint kinematics and surface electromyography signals (sEMG) from eight muscles in 12 healthy subjects during standard and fatigue stages. Two muscle synergies are derived from sEMG signals and are analyzed comprehensively along with joint kinematics. Our findings reveal a shift in the relative contribution of forearm muscles to shoulder muscles, accompanied by a significant increase in activation amplitude for both synergies. Additionally, more pronounced movement was observed at the shoulder joint during fatigue. These results suggest focusing on the shoulder muscle activities and joint motions when deploying wearable sensors to effectively detect compensatory movements.

cs.RO

A Low-Cost Teleoperable Surgical Robot with a Macro-Micro Structure and a Continuum Tip for Open-Source Research

Surgical robotic systems equipped with microscale, high-dexterity manipulators have shown promising results in minimally invasive surgery (MIS). One barrier to the widespread adoption of such systems is the prohibitive cost of research and development efforts using current state-of-the-art equipment. To address this challenge, this paper proposes a low-cost and modifiable tendon-driven continuum manipulator for MIS applications. The device is capable of being teleoperated in conjunction with a macro-scale six-axis robotic arm using a haptic stylus. Its control software incorporates and extends freely available and open-source software packages. For verification, we perform teleoperation trials on the proposed continuum manipulator using an electromagnetic tracker. We then integrate the manipulator with a UR5e robotic arm. A series of simulated tumour biopsies were conducted using the integrated robotic system and an anatomical model (phantom), validating its potential efficacy in MIS applications. The complete source code, CAD files for all additively manufactured components, a parts list for the manipulator, and a demonstration video of the proposed system are made available in this work.

cs.RO

A Mechatronic System for the Visualisation and Analysis of Orchestral Conducting

This paper quantitatively analysed orchestral conducting patterns, and detected variations as a result of extraneous body movement during conducting, in the first experiment of its kind. A novel live conducting system featuring data capture, processing, and analysis was developed. Reliable data of an expert conductor's movements was collected, processed, and used to calculate average trajectories for different conducting techniques with various extraneous body movements; variations between extraneous body movement techniques and controlled technique were definitively determined in a novel quantitative analysis. A portable and affordable mechatronic system was created to capture and process live baton tip data, and was found to be accurate through calibration against a reliable reference. Experimental conducting field data was captured through the mechatronic system, and analysed against previously calculated average trajectories; the extraneous movement used during the field data capture was successfully identified by the system.

cs.RO

Geometric interpretation of the general POE model for a serial-link robot via conversion into D-H parameterization

While Product of Exponentials (POE) formula has been gaining increasing popularity in modeling the kinematics of a serial-link robot, the Denavit-Hartenberg (D-H) notation is still the most widely used due to its intuitive and concise geometric interpretation of the robot. This paper has developed an analytical solution to automatically convert a POE model into a D-H model for a robot with revolute, prismatic, and helical joints, which are the complete set of three basic one degree of freedom lower pair joints for constructing a serial-link robot. The conversion algorithm developed can be used in applications such as calibration where it is necessary to convert the D-H model to the POE model for identification and then back to the D-H model for compensation. The equivalence of the two models proved in this paper also benefits the analysis of the identifiability of the kinematic parameters. It is found that the maximum number of identifiable parameters in a general POE model is 5h+4r +2t +n+6 where h, r, t, and n stand for the number of helical, revolute, prismatic, and general joints, respectively. It is also suggested that the identifiability of the base frame and the tool frame in the D-H model is restricted rather than the arbitrary six parameters as assumed previously.

cs.RO

Model-less Active Compliance for Continuum Robots using Recurrent Neural Networks

Endowing continuum robots with compliance while it is interacting with the internal environment of the human body is essential to prevent damage to the robot and the surrounding tissues. Compared with passive compliance, active compliance has the advantages in terms of increasing the force transmission ability and improving safety with monitored force output. Previous studies have demonstrated that active compliance can be achieved based on a complex model of the mechanics combined with a traditional machine learning technique such as a support vector machine. This paper proposes a recurrent neural network based approach that avoids the complexity of modeling while capturing nonlinear factors such as hysteresis, friction and delay of the electronics that are not easy to model. The approach is tested on a 3-tendon single-segment continuum robot with force sensors on each cable. Experiments are conducted to demonstrate that the continuum robot with an RNN based feed-forward controller is capable of responding to external forces quickly and entering an unknown environment compliantly.

cs.RO

Camera Frame Misalignment in a Teleoperated Eye-in-Hand Robot: Effects and a Simple Correction Method

Misalignment between the camera frame and the operator frame is commonly seen in a teleoperated system and usually degrades the operation performance. The effects of such misalignment have not been fully investigated for eye-in-hand systems - systems that have the camera (eye) mounted to the end-effector (hand) to gain compactness in confined spaces such as in endoscopic surgery. This paper provides a systematic study on the effects of the camera frame misalignment in a teleoperated eye-in-hand robot and proposes a simple correction method in the view display. A simulation is designed to compare the effects of the misalignment under different conditions. Users are asked to move a rigid body from its initial position to the specified target position via teleoperation, with different levels of misalignment simulated. It is found that misalignment between the input motion and the output view is much more difficult to compensate by the operators when it is in the orthogonal direction (~40s) compared with the opposite direction (~20s). An experiment on a real concentric tube robot with an eye-in-hand configuration is also conducted. Users are asked to telemanipulate the robot to complete a pick-and-place task. Results show that with the correction enabled, there is a significant improvement in the operation performance in terms of completion time (mean 40.6%, median 38.6%), trajectory length (mean 34.3%, median 28.1%), difficulty (50.5%), unsteadiness (49.4%), and mental stress (60.9%).

cs.RO

Haptics-Enabled Forceps with Multi-Modal Force Sensing: Towards Task-Autonomous Surgery

Many robotic surgical systems have been developed with micro-sized forceps for tissue manipulation. However, these systems often lack force sensing at the tool side and the manipulation forces are roughly estimated and controlled relying on the surgeon's visual perception. To address this challenge, we present a vision-based module to enable the micro-sized forceps' multi-modal force sensing. A miniature sensing module adaptive to common micro-sized forceps is proposed, consisting of a flexure, a camera, and a customised target. The deformation of the flexure is obtained by the camera estimating the pose variation of the top-mounted target. Then, the external force applied to the sensing module is calculated using the flexure's displacement and stiffness matrix. Integrating the sensing module into the forceps, in conjunction with a single-axial force sensor at the proximal end, we equip the forceps with haptic sensing capabilities. Mathematical equations are derived to estimate the multi-modal force sensing of the haptics-enabled forceps, including pushing/pulling forces (Mode-I) and grasping forces (Mode-II). A series of experiments on phantoms and ex vivo tissues are conducted to verify the feasibility of the proposed design and method. Results indicate that the haptics-enabled forceps can achieve multi-modal force estimation effectively and potentially realize autonomous robotic tissue grasping procedures with controlled forces. A video demonstrating the experiments can be found at https://youtu.be/pi9bqSkwCFQ.

cs.RO

Real-time Joint Motion Analysis and Instrument Tracking for Robot-Assisted Orthopaedic Surgery

Robotic-assisted orthopaedic surgeries demand accurate, automated leg manipulation for improved spatial accuracy to reduce iatrogenic damage. In this study, we propose novel rigid body designs and an optical tracking volume setup for tracking of the femur, tibia and surgical instruments. Anatomical points inside the leg are measured using Computed Tomography with an accuracy of 0.3mm. Combined with kinematic modelling, we can express these points relative to any frame and across joints to sub-millimetre accuracy. It enables the setup of vectors on the mechanical axes of the femur and tibia for kinematic analysis. Cadaveric experiments are used to verify the tracking of internal anatomies and joint motion analysis. The proposed integrated solution is a first step in the automation of leg manipulation and can be used as a ground-truth for future robot-assisted orthopaedic research.

cs.RO

Optimal Dexterity for a Snake-like Surgical Manipulator using Patient-specific Task-space Constraints in a Computational Design Algorithm

Tendon-driven snake-like arms have been used to create highly dexterous continuum robots so that they can bend around anatomical obstacles to access clinical targets. In this paper, we propose a design algorithm for developing patient-specific surgical continuum manipulators optimized for oriental dexterity constrained by task-space obstacles. The algorithm uses a sampling-based approach to finding the dexterity distribution in the workspace discretized by voxels. The oriental dexterity measured in the region of interest in the task-space formed a fitness function to be optimized through differential evolution. This was implemented in the design of a tendon-driven manipulator for knee arthroscopy. The results showed a feasible design that achieves significantly better dexterity than a rigid tool. This highlights the potential of the proposed method to be used in the process of designing dexterous surgical manipulators in the field.

cs.RO

The ACRV Picking Benchmark (APB): A Robotic Shelf Picking Benchmark to Foster Reproducible Research

Robotic challenges like the Amazon Picking Challenge (APC) or the DARPA Challenges are an established and important way to drive scientific progress. They make research comparable on a well-defined benchmark with equal test conditions for all participants. However, such challenge events occur only occasionally, are limited to a small number of contestants, and the test conditions are very difficult to replicate after the main event. We present a new physical benchmark challenge for robotic picking: the ACRV Picking Benchmark (APB). Designed to be reproducible, it consists of a set of 42 common objects, a widely available shelf, and exact guidelines for object arrangement using stencils. A well-defined evaluation protocol enables the comparison of \emph{complete} robotic systems -- including perception and manipulation -- instead of sub-systems only. Our paper also describes and reports results achieved by an open baseline system based on a Baxter robot.

cs.RO