SearcharxivSearch

arXiv subjects

Lorenzo Ferrari Barusso

Publications and source records attributed to Lorenzo Ferrari Barusso.

5 recordsLinked to original sources

Letter Of Intent for a future $μ^+ \to \mathrm{e}^+ γ$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $μ^+ \to \mathrm{e}^+ γ$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $μ^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $μ\to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $μ^+ \to \mathrm{e}^+ γ$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $μ^+ \to \mathrm{e}^+ γ$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $μ^+ \to \mathrm{e}^+ γ$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex

Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment

We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.

physics.ins-det

The TES-based Cryogenic AntiCoincidence Detector of ATHENA X-IFU: Validation of the thermal end-to-end simulator towards the updated Demonstration Model (DM 1.1)

The Cryogenic AntiCoincidence Detector (CryoAC) is a key element of the X-ray Integral Field Unit (X-IFU) on board the future ATHENA X-ray observatory. It is a TES-based detector designed to reduce the particle background of the instrument, thereby increasing its sensitivity. The detector design is driven by an end-to-end simulator which includes the electro-thermal modelling of the detector and the dynamics of its readout chain. Here, we present the measurements carried out on the last CryoAC single pixel prototype, namely DM127, in order to evaluate the critical thermal parameters of the detector and consequently to tune and validate the CryoAC end-to-end simulator.

astro-ph.IM

The end-to-end simulator of the ATHENA X-IFU Cryogenic AntiCoincidence detector (CryoAC)

The X-IFU is one of the two instruments of ATHENA, the next ESA large X-ray observatory. It is a cryogenic spectrometer based on an array of TES microcalorimeters. To reduce the particle background, the TES array works in combination with a Cryogenic AntiCoincidence detector (CryoAC). The CryoAC is a 4-pixel detector, based on ~1 cm2 silicon absorbers sensed by Ir/Au TES. It is required to have a wide energy bandwidth (from 20 keV to ~1 MeV), high efficiency (< 0.014% missed particles), low dead-time (< 1%) and good time-tagging accuracy (10 us at 1 sigma). An end-to-end simulator of the CryoAC detector has been developed both for design and performance assessment, consisting of several modules. First, the in-flight flux of background particles is evaluated by Geant4 simulations. Then, the current flow in the TES is evaluated by solving the electro-thermal equations of microcalorimeters, and the detector output signal is generated by simulating the SQUID FLL dynamics. Finally, the output is analyzed by a high-efficiency trigger algorithm, producing the simulated CryoAC telemetry. Here, we present in detail this end-to-end simulator, and how we are using it to define the new CryoAC baseline configuration in the new Athena context.

astro-ph.IM

The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector

The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.

astro-ph.IM