Searcharxiv⌕ Search

arXiv subjects

Lucio Piccirillo

Publications and source records attributed to Lucio Piccirillo.

26 records · Page 2Linked to original sources

B-Pol: Detecting Primordial Gravitational Waves Generated During Inflation

B-Pol is a medium-class space mission aimed at detecting the primordial gravitational waves generated during inflation through high accuracy measurements of the Cosmic Microwave Background (CMB) polarization. We discuss the scientific background, feasibility of the experiment, and implementation developed in response to the ESA Cosmic Vision 2015-2025 Call for Proposals.

astro-ph↗

Observing CMB polarisation through ice

Ice crystal clouds in the upper troposphere can generate polarisation signals at the uK level. This signal can seriously affect very sensitive ground based searches for E- and B-mode of Cosmic Microwave Background polarisation. In this paper we estimate this effect within the ClOVER experiment observing bands (97, 150 and 220 GHz) for the selected observing site (Llano de Chajnantor, Atacama desert, Chile). The results show that the polarisation signal from the clouds can be of the order of or even bigger than the CMB expected polarisation. Climatological data suggest that this signal is fairly constant over the whole year in Antarctica. On the other hand the stronger seasonal variability in Atacama allows for a 50% of clean observations during the dry season.

astro-ph↗

Prototype finline-coupled TES bolometers for CLOVER

CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to ensure a 100% operational focal plane. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and present preliminary measurements of the prototype detectors performance.

astro-ph↗

TES imaging array technology for CLOVER

CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the required NEPs the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to guarantee fully functioning focal planes. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and give an update on the detector development.

astro-ph↗

COMPASS: An Upper Limit on CMB Polarization at an Angular Scale of 20 arc minutes

COMPASS is an on-axis 2.6 meter telescope coupled to a correlation polarimeter operating at a wavelength of 1 cm. The entire instrument was built specifically for CMB polarization studies. We report here on observations of February 2001 - April 2001 using this system. We set an upper limit on E-mode polarized anisotropies of 33.5 uK (95% confidence limit) in the l-range 200-600.

astro-ph↗

COMPASS: An Instrument for Measuring the Polarization of the CMB on Intermediate Angular Scales

COMPASS is an on-axis 2.6 meter telescope coupled to a correlation polarimeter. The entire instrument was built specifically for CMB polarization studies. Careful attention was given to receiver and optics design, stability of the pointing platform, avoidance of systematic offsets, and development of data analysis techniques. Here we describe the experiment, its strengths and weaknesses, and the various things we have learned that may benefit future efforts to measure the polarization of the CMB.

astro-ph↗

An Instrument for Investigating the Large Angular Scale Polarization of the Cosmic Microwave Background

We describe the design and performance of a microwave polarimeter used to make precision measurements of polarized astrophysical radiation in three microwave frequency bands spanning 26-36 GHz. The instrument uses cooled HEMT amplifiers in a correlation polarimeter configuration to achieve high sensitivity and long-term stability. The instrument demonstrates long term stability and has produced the most restrictive upper limits to date on the large angular scale polarization of the 2.7 K cosmic microwave background radiation.

astro-ph↗

A Limit on the Large Angular Scale Polarization of the Cosmic Microwave Background

We present an upper limit on the polarization of the Cosmic Microwave Background at 7 degree angular scales in the frequency band between 26 and 36 GHz, produced by the POLAR experiment. The campaign produced a map of linear polarization over the R.A. range 112 degrees - 275 degrees at declination 43degrees. The model-independent upper limit on the E-mode polarization component of the CMB at angular scales l = 2 - 20 is 10 microKelvin (95% confidence). The corresponding limit for the B-mode is also 10 microKelvin. Constraining the B-mode power to be zero, the 95% confidence limit on E-mode power alone is 8 microKelvin.

astro-ph↗