Searcharxiv⌕ Search

arXiv subjects

Luigi Piro

Publications and source records attributed to Luigi Piro.

At least 37 records · Page 2Linked to original sources

Review of the particle background of the Athena X-IFU instrument

X-ray observations are limited by the background, due to intrinsic faintness or diffuse nature of the sources. The future Athena X-ray observatory has among its goals the characterization of these sources. We aim at characterizing the particle-induced background of the Athena microcalorimeter, in both its low (Soft Protons) and high (GCR) energy induced components, to assess the instrument capability to characterize background dominated sources such as the outskirts of clusters of galaxies. We compare two radiation environments, namely the L1 and L2 Lagrangian points, and derive indications against the latter. We estimate the particle-induced background level on the X-IFU microcalorimeter with Monte Carlo simulations, before and after all the solutions adopted to reduce its level. Concerning the GCR induced component the background level is compliant with the mission requirement. Regarding the Soft Protons component, the analysis does not predict dramatically different backgrounds in the L1 and L2 orbits. However, the lack of data concerning the L2 environment labels it as very weakly characterizable, and thus we advise against its choice as orbit for X-ray missions. We then use these background levels to simulate the observation of a typical galaxy cluster from its center out to 1.2 R200 to probe the characterization capabilities of the instrument out to the outskirts. We find that without any background reduction it is not possible to characterize the properties of the cluster in the outer regions. We also find no improvement of the observations when carried out during the solar maximum with respect to the solar minimum conditions.

astro-ph.IM↗

Searching for the radio remnants of short duration gamma-ray bursts

Neutron star mergers produce a substantial amount of fast-moving ejecta, expanding outwardly for years after the merger. The interaction of these ejecta with the surrounding medium may produce a weak isotropic radio remnant, detectable in relatively nearby events. We use late-time radio observations of short duration gamma-ray bursts (sGRBs) to constrain this model. Two samples of events were studied: four sGRBs that are possibly in the local (<200 Mpc) universe were selected to constrain the remnant non-thermal emission from the sub-relativistic ejecta, whereas 17 sGRBs at cosmological distances were used to constrain the presence of a proto-magnetar central engine, possibly re-energezing the merger ejecta. We consider the case of GRB~170817A/GW170817, and find that in this case the early radio emission may be quenched by the jet blast-wave. In all cases, for ejecta mass range of M_ej \lesssim 10^{-2} (5 * 10^{-2}) M_sun, we can rule out very energetic merger ejecta E_ej \gtrsim 5 * 10^{52}(10^{53}) erg, thus excluding the presence of a powerful magnetar as a merger remnant.

astro-ph.HE↗

The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector

The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here we report the test performed on the first CryoAC DM sample (namely the AC-S10 prototype), showing that it is fully compliant with its requirements.

astro-ph.IM↗

Gamma-Ray Burst Afterglows In The Multi-Messenger Era: Numerical Models and Closure Relations

Gamma-ray bursts (GRBs) associated with gravitational wave events are, and will likely continue to be, viewed at a larger inclination than GRBs without gravitational wave detections. As demonstrated by the afterglow of GW170817, this requires an extension of the common GRB afterglow models which typically assume emission from an on-axis top hat jet. We present a characterization of the afterglows arising from structured jets, providing a framework covering both successful and choked jets. We compute new closure relations for structured jets and compare with the established relations for energy injection and refreshed shock models. The temporal slope before the jet break is found to be a simple function of the ratio between the viewing angle and effective opening angle of the jet. A numerical model to calculate synthetic light curves and spectra is publicly available as the open source Python package afterglowpy.

astro-ph.HE↗

Magnetic shielding of soft protons in future X-ray telescopes: the case of the ATHENA Wide Field Imager

Both the interplanetary space and the Earth magnetosphere are populated by low energy ($\leq300$ keV) protons that are potentially able to scatter on the reflecting surface of Wolter-I optics of X-ray focusing telescopes and reach the focal plane. This phenomenon, depending on the X-ray instrumentation, can dramatically increase the background level, reducing the sensitivity or, in the most extreme cases, compromising the observation itself. The use of a magnetic diverter, deflecting protons away from the field of view, requires a detailed characterization of their angular and energy distribution when exiting the mirror. We present the first end-to-end Geant4 simulation of proton scattering by X-ray optics and the consequent interaction with the diverter field and the X-ray detector assembly, selecting the ATHENA Wide Field Imager as a case study for the evaluation of the residual soft proton induced background. We obtain that, in absence of a magnetic diverter, protons are indeed funneled towards the focal plane, with a focused Non X-ray Background well above the level required by ATHENA science objectives ($5\times10^{-4}$ counts cm$^{-2}$ s$^{-1}$ keV$^{-1}$), for all the plasma regimes encountered in both L1 and L2 orbits. These results set the proton diverter as a mandatory shielding system on board the ATHENA mission and all high throughput X-ray telescopes operating in the interplanetary space. For a magnetic field computed to deflect 99\% of the protons that would otherwise reach the WFI, Geant4 simulations show that this configuration, in the assumption of a uniform field, would efficiently shield the focal plane, yielding a residual background level of the order or below the requirement.

astro-ph.IM↗

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of the test setup towards the Demonstration Model

The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the TES array. Before the delivery, we will characterize and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the main results of the activities performed to improve our cryogenic test setup, making it suitable for the DM integration. These activities mainly consist in the development of a mechanichal setup and a cryogenic magnetic shielding system, whose effectiveness has been assessed by FEM simulations and a measurement at warm. The preliminary performance test has been performed by means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.

astro-ph.IM↗

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the role of the athermal phonons collectors in the AC-S8 prototype

The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below the TES array. The last CryoAC single-pixel prototypes, namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers sensed by 65 parallel-connected iridium TES. This design has been adopted to improve the response generated by the athermal phonons, which will be used as fast anticoincidence flag. The latter sample is featured also with a network of Aluminum fingers directly connected to the TES, designed to further improve the athermals collection efficiency. In this paper we will report the main results obtained with AC-S8, showing that the additional fingers network is able to increase the energy collected from the athermal part of the pulses (from the 6% of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to prevent the quasiparticle recombination in the aluminum, assuring a fast pulse rising front (L/R limited). In our road map, the AC-S8 prototype is the last step before the development of the CryoAC Demonstration Model (DM), which will be the detector able to demonstrate the critical technologies expected in the CryoAC development programme.

astro-ph.IM↗

The Athena X-ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of about 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.

astro-ph.IM↗

The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model

Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bath, the threshold energy at 20 keV and the reproducibility of the thermal conductance between the suspended absorber and the thermal bath. This detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and then delivered to SRON for the integration in the X-IFU Focal Plane Assemby (FPA) DM. In this paper we report the status of the CryoAC DM development, showing the main result obtained with the last developed prototype, namely AC-S9. This is a DM-like sample, which we have preliminary integrated and tested before performing the final etching process to suspend the silicon absorber. The results are promising for the DM, since despite the limitations due to the absence of the final etching (high thermal capacity, high thermal conductance, partial TES surface coverage), we have been able to operate the detector with TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold fully compatible with our requirement (20 keV).

astro-ph.IM↗

Reproducibility and monitoring of the instrumental particle background for the X-Ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) is the cryogenic imaging spectrometer on board the future X-ray observatory \textsl{Athena}. With a hexagonal array of 3840 AC-biased Transition Edge Sensors (TES), it will provide narrow-field observations (5$^{\prime}$ equivalent diameter) with unprecedented high spectral resolution (2.5 eV up to 7 keV) over the 0.2 - 12 keV bandpass. Throughout its observations, the X-IFU will face various sources of X-ray background. Specifically, the so-called Non-X-ray Background (NXB) caused by the interaction of high-energy cosmic rays with the instrument, may lead to a degradation of its sensitivity in the observation of faint extended sources (e.g. galaxy clusters outskirts). To limit this effect, a cryogenic anti-coincidence detector (CryoAC) will be placed below the detector plane to lower the NXB level down to the required level of $5 \times 10^{-3}$ cts/s/cm$^{2}$/keV over 2 - 10 keV. In this contribution, we investigate ways to accurately monitor the NXB and ensure the highest reproducibility in-flight. Using the limiting science case of the background-dominated observation of galaxy clusters outskirts, we demonstrate that a reproducibility of 2\% on the absolute knowledge of the background is required to perform driving science objectives, such as measuring abundances and turbulence in the outskirts. Monitoring of the NXB in-flight through closed observations, the detector's CryoAC or the companion instrument (Wide Field Imager) will be used to meet this requirement.

astro-ph.IM↗

The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering

Given the unprecedented effective area, the new ATHENA Silicon Pore Optics (SPO) focusing technology, the dynamic and variable L2 environment, where no X-ray mission has flown up to date, a dedicated Geant4 simulation campaign is needed to evaluate the impact of low energy protons scattering on the ATHENA mirror surface and the induced residual background level on its X-ray detectors. The Geant4 mass model is built as part of the ESA AREMBES project activities using the BoGEMMS framework. An SPO mirror module row is the atomic unit of the mass model, allowing the simulation of the full structure by means of 20 independent runs, one for each row. Thanks to the BoGEMMS configuration files, both single pores, mirror modules or the entire SPO row can be built with the same Geant4 geometry. Both Remizovich, in its elastic approximation, and Coulomb single scattering Geant4 models are used in the interaction of mono-energetic proton beams with a single SPO pore. The scattering efficiency for the first model is almost twice the efficiency obtained with the latter but for both cases we obtain similar polar and azimuthal angular distributions, with about 70-75% of scatterings generated by single or double reflections. The soft proton flux modelled for the plasma sheet region is used as input for the simulation of soft proton funnelling by the full SPO mass model. A much weaker soft proton vignetting than the one observed by XMM-Newton EPIC detectors is generated by ATHENA mirrors. The residual soft proton flux reaching the focal plane, defined as a 15 cm radius, is 10^4 times lower than the input L2 soft proton population entering the mirror, at the same energy, with rates comparable or higher than the ones observed in XMM EPIC-pn most intense soft proton flares.

astro-ph.IM↗

The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band

ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed <1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E>10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.

astro-ph.IM↗

The particle background of the X-IFU instrument

In this paper we are going to review the latest estimates for the particle background expected on the X-IFU instrument onboard of the ATHENA mission. The particle background is induced by two different particle populations: the so called "soft protons" and the Cosmic rays. The first component is composed of low energy particles (< 100s keV) that get funnelled by the mirrors towards the focal plane, losing part of their energy inside the filters and inducing background counts inside the instrument sensitivity band. The latter component is induced by high energy particles (> 100 MeV) that possess enough energy to cross the spacecraft and reach the detector from any direction, depositing a small fraction of their energy inside the instrument. Both these components are estimated using Monte Carlo simulations and the latest results are presented here.

astro-ph.IM↗

Updates on the background estimates for the X-IFU instrument onboard of the ATHENA mission

ATHENA, with a launch foreseen in 2028 towards the L2 orbit, addresses the science theme "The Hot and Energetic Universe", coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these, the X-ray Integral Field Unit (X-IFU) is a TES based kilo-pixel array providing spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The background for this kind of detectors accounts for several components: the diffuse Cosmic X-ray Background, the low energy particles (<~100 keV) focalized by the mirrors and reaching the detector from inside the field of view, and the high energy particles (>~100 MeV) crossing the spacecraft and reaching the focal plane from every direction. Each one of these components is under study to reduce their impact on the instrumental performances. This task is particularly challenging, given the lack of data on the background of X-ray detectors in L2, the uncertainties on the particle environment to be expected in such orbit, and the reliability of the models used in the Monte Carlo background computations. As a consequence, the activities addressed by the group range from the reanalysis of the data of previous missions like XMM-Newton, to the characterization of the L2 environment by data analysis of the particle monitors onboard of satellites present in the Earth magnetotail, to the characterization of solar events and their occurrence, and to the validation of the physical models involved in the Monte Carlo simulations. All these activities will allow to develop a set of reliable simulations to predict, analyze and find effective solutions to reduce the particle background experienced by the X-IFU, ultimately satisfying the scientific requirement that enables the science of ATHENA. While the activities are still ongoing, we present here some preliminary results already obtained by the group.

astro-ph.IM↗

The Athena X-ray Integral Field Unit (X-IFU)

The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for High-ENergy Astrophysics (Athena) will provide spatially resolved high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels over a field of view of 5 arc minute equivalent diameter and a spectral resolution of 2.5 eV up to 7 keV. In this paper, we first review the core scientific objectives of Athena, driving the main performance parameters of the X-IFU, namely the spectral resolution, the field of view, the effective area, the count rate capabilities, the instrumental background. We also illustrate the breakthrough potential of the X-IFU for some observatory science goals. Then we briefly describe the X-IFU design as defined at the time of the mission consolidation review concluded in May 2016, and report on its predicted performance. Finally, we discuss some options to improve the instrument performance while not increasing its complexity and resource demands (e.g. count rate capability, spectral resolution). The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with further ESA member state contributions from Belgium, Finland, Germany, Poland, Spain, Switzerland and two international partners from the United States and Japan.

astro-ph.IM↗

A hot cocoon in the ultralong GRB 130925A: hints of a PopIII-like progenitor in a low density wind environment

GRB 130925A is a peculiar event characterized by an extremely long gamma-ray duration ($\approx$7 ks), as well as dramatic flaring in the X-rays for $\approx$20 ks. After this period, its X-ray afterglow shows an atypical soft spectrum with photon index $Γ$$\sim$4, as observed by Swift and Chandra, until $\approx 10^7$ s, when XMM-Newton observations uncover a harder spectral shape with $Γ$$\sim$2.5, commonly observed in GRB afterglows. We find that two distinct emission components are needed to explain the X-ray observations: a thermal component, which dominates the X-ray emission for several weeks, and a non-thermal component, consistent with a typical afterglow. A forward shock model well describes the broadband (from radio to X-rays) afterglow spectrum at various epochs. It requires an ambient medium with a very low density wind profile, consistent with that expected from a low-metallicity blue supergiant (BSG). The thermal component has a remarkably constant size and a total energy consistent with those expected by a hot cocoon surrounding the relativistic jet. We argue that the features observed in this GRB (its ultralong duration, the thermal cocoon, and the low density wind environment) are associated with a low metallicity BSG progenitor and, thus, should characterize the class of ultralong GRBs.

astro-ph.HE↗

The Hot and Energetic Universe: A White Paper presenting the science theme motivating the Athena+ mission

This White Paper, submitted to the recent ESA call for science themes to define its future large missions, advocates the need for a transformational leap in our understanding of two key questions in astrophysics: 1) How does ordinary matter assemble into the large scale structures that we see today? 2) How do black holes grow and shape the Universe? Hot gas in clusters, groups and the intergalactic medium dominates the baryonic content of the local Universe. To understand the astrophysical processes responsible for the formation and assembly of these large structures, it is necessary to measure their physical properties and evolution. This requires spatially resolved X-ray spectroscopy with a factor 10 increase in both telescope throughput and spatial resolving power compared to currently planned facilities. Feedback from supermassive black holes is an essential ingredient in this process and in most galaxy evolution models, but it is not well understood. X-ray observations can uniquely reveal the mechanisms launching winds close to black holes and determine the coupling of the energy and matter flows on larger scales. Due to the effects of feedback, a complete understanding of galaxy evolution requires knowledge of the obscured growth of supermassive black holes through cosmic time, out to the redshifts where the first galaxies form. X-ray emission is the most reliable way to reveal accreting black holes, but deep survey speed must improve by a factor ~100 over current facilities to perform a full census into the early Universe. The Advanced Telescope for High Energy Astrophysics (Athena+) mission provides the necessary performance (e.g. angular resolution, spectral resolution, survey grasp) to address these questions and revolutionize our understanding of the Hot and Energetic Universe. These capabilities will also provide a powerful observatory to be used in all areas of astrophysics.

astro-ph.HE↗

The Hot and Energetic Universe: The missing baryons and the warm-hot intergalactic medium

The backbone of the large-scale structure of the Universe is determined by processes on a cosmological scale and by the gravitational interaction of the dominant dark matter. However, the mobile baryon population shapes the appearance of these structures. Theory predicts that most of the baryons reside in vast unvirialized filamentary structures that connect galaxy groups and clusters, but the observational evidence is currently lacking. Because the majority of the baryons are supposed to exist in a large-scale, hot and dilute gaseous phase, X-rays provide the ideal tool to progress our understanding. Observations with the Athena+ X-ray Integral Field Unit will reveal the location, chemical composition, physical state and dynamics of the active population of baryons.

astro-ph.HE↗