Searcharxiv⌕ Search

arXiv subjects

M. Atzori Corona

Publications and source records attributed to M. Atzori Corona.

At least 19 recordsLinked to original sources

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of $2.94\pm0.05_{\text{stat}}\pm0.74_{\text{syst}}$~eV using a CaWO$_4$ based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.

physics.ins-det↗

Phenomenological implications of the high-precision COHERENT germanium CE$ν$NS data

This work presents the first comprehensive phenomenological analysis of the newly released Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) data on germanium, measured by the COHERENT collaboration at the Spallation Neutron Source. Leveraging the unprecedented precision of this dataset, we provide state-of-the-art determinations of key Standard Model and nuclear physics parameters. Specifically, we extract updated constraints on the weak mixing angle, the neutrino charge radii, and we perform a detailed extraction of the neutron root-mean-square radius of germanium nuclei. We also investigate the impact of quenching factor uncertainties by exploring an extended Lindhard framework, and assess their effect on the extraction of nuclear parameters. Additionally, we use these results to evaluate scenarios beyond the Standard Model, placing robust bounds on neutrino non-standard interactions. To maximize the statistical power and robustness of our findings, whenever possible, we perform a global combined analysis incorporating previous COHERENT measurements along with reactor antineutrino data from the CONUS+, TEXONO, and $ν$GeN experiments as well as dark-matter experiments.

hep-ph↗

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

physics.ins-det↗

Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment

The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CE$ν$NS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO$_4$ detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of $\overlineσ_{\mathrm{BL}} = (2.79 \pm 0.60)\,\mathrm{eV}$ was achieved. The best-performing detector reached $σ_{\mathrm{BL}} = (2.16 \pm 0.02_{\mathrm{stat}})\,\mathrm{eV}$, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO$_4$ detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CE$ν$NS measurements.

physics.ins-det↗

Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches

The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$ν$NS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters operated at the Chooz nuclear power plant in France. Access to recoil energies at the $\mathcal{O}(10~\mathrm{eV})$ scale enables CE$ν$NS studies at extremely low momentum transfer and provides enhanced sensitivity to new physics. In this work, we present sensitivity projections for the upcoming NUCLEUS technical and physics runs, incorporating a data-driven treatment of the low-energy excess (LEE) observed during commissioning. We develop a likelihood framework that exploits reactor-power variation to disentangle signal and background in a low signal-to-background regime and to assess the impact of the dominant systematic uncertainties. For the Technical Run with a 7 g CaWO$_4$ target, we find competitive sensitivity to several scenarios beyond the Standard Model, which do not require a CE$ν$NS observation. For the Physics Run, assuming complete suppression of the LEE, we project a 4.7 $σ$ observation of CE$ν$NS with a statistical precision of about 20 % in 1 year, enabling a determination of the weak mixing angle at the lowest momentum transfer probed to date with CE$ν$NS and leading CE$ν$NS-based constraints on the neutrino charge radius and new mediator models.

hep-ex↗

When backgrounds become signals: neutrino interactions in xenon-based dark matter detectors

Direct detection dark matter experiments have proven to be compelling probes for studying low-energy neutrino interactions with both nuclei and atomic electrons, offering complementary information to accelerator and reactor-based neutrino experiments. Recently, the XENONnT and PandaX-4T collaborations reported the first evidence of coherent elastic neutrino-nucleus scattering from $^8\mathrm{B}$ solar neutrinos. Thanks to their excellent background rejection capabilities and distinctive signal signatures, dual-phase time projection chambers are also sensitive to $pp$ solar neutrinos via their elastic scattering off atomic electrons in the target material. Although this signal is subdominant within the Standard Model, it becomes significantly enhanced in many beyond the Standard Model scenarios, offering a unique opportunity to probe new physics in the low-energy regime. In this work, we analyze the latest electron recoil and nuclear recoil data from XENONnT, PandaX-4T, and LUX-ZEPLIN to probe Standard Model and Beyond the Standard Model physics. While the precision of current neutrino measurements from such detectors remains lower than that achieved by dedicated neutrino experiments, their sensitivity to the tau neutrino component of solar neutrinos helps complete the overall picture, especially when investigating flavor-dependent new physics effects.

hep-ph↗

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide programme

Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass WIMP interactions, setting new world-leading constraints in the 1-3 GeV/c^2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.

hep-ex↗

Characterization of argon recoils at the keV scale with ReD and ReD+

The ReD experiment measured the ionization yield Qy of argon for nuclear recoils in the 2-10 keV range using a dual-phase Time Projection Chamber irradiated with neutrons from a Cf-252 fission source. The measurement extends coverage below 7 keV, confirms consistency with previous data above 7 keV, and indicates a higher Qy at lower energies. These results are relevant for argon-based experiments searching for dark matter in the form of low-mass Weakly Interacting Massive Particles, which are very sensitive to the modeling of the detector response in this energy range.

hep-ex↗

Toward precision physics tests with future COHERENT detectors

We present a comprehensive sensitivity study of future CE$ν$NS detectors, focusing on a cryogenic cesium iodide detector and a tonne-scale liquid argon one, currently being developed by the COHERENT Collaboration. These setups will enable precision measurements of the weak mixing angle at low energies and allow accurate extraction of the neutron nuclear distribution radius. We also demonstrate that next-generation detectors will place constraints on the neutrino charge radius comparable to or better than current global fits. In addition, we explore the sensitivity to non standard neutrino electromagnetic properties, such as magnetic moments and millicharges, as well as new mediators. These findings reinforce the role of CE$ν$NS experiments in the upcoming precision era, with future detectors playing a key role in advancing our understanding of neutrino interactions and electroweak physics at low energies.

physics.ins-det↗

Particle background characterization and prediction for the NUCLEUS reactor CE$ν$NS experiment

NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE$ν$NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE$ν$NS signal region of interest between 10 and 100 eV, a total particle background rate of $\sim$ 250 d$^{-1}$kg$^{-1}$keV$^{-1}$ is expected in the CaWO$_4$ target detectors. This corresponds to a signal-to-background ratio $\gtrsim$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE$ν$NS.

physics.ins-det↗

Commissioning of the NUCLEUS Experiment at the Technical University of Munich

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO$_4$ targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW$_{\text{th}}$ reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.

hep-ex↗

Characterization of the ionization response of argon to nuclear recoils at the keV scale with the ReD experiment

In the recent years, argon-based experiments looking for Dark Matter in the Universe have explored the non-standard scenario in which Dark Matter is made by low-mass Weakly Interacting Massive Particles, of mass in the range of 1-10 GeV instead of the canonical hundreds of GeV. Detecting such particles is challenging, as their expected signatures are nuclear recoils with energies below 10 keV, observable solely via ionization. This necessitates a precise understanding of the detector response in this energy regime, which remains incomplete for argon. To address this, the ReD experiment was developed within the framework of the DarkSide-20k Collaboration to produce and characterize few-keV nuclear recoils. A compact dual-phase argon Time Projection Chamber (TPC) was irradiated with neutrons from a Cf252 source, to produce Ar recoils in the energy range of interest via (n,n') elastic scattering. A downstream spectrometer composed of 18 plastic scintillators detected the neutrons scattered off Ar nuclei, enabling recoil energy reconstruction via two-body kinematics. The ionization yield Qy of argon, defined as the number of electrons produced per unit energy deposit, was measured in a model-independent way between 2 and 10 keV. These measurements extend direct experimental coverage well below the previous limit of approximately 7 keV. The results are consistent with existing data above 7 keV, while they indicate a higher Qy at lower energies.

nucl-ex↗

Joint analysis of reactor and accelerator CE$ν$NS data on germanium: implications for the Standard Model and nuclear physics

This work presents the first comprehensive joint analysis of all available Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) data on germanium: those observed at the Spallation Neutron Source (SNS) by the COHERENT collaboration and those of the nuclear reactors revealed by the CONUS+ experiment using germanium detectors. In addition to COHERENT and CONUS+, we incorporate reactor data from TEXONO and $ν$GeN, thereby enhancing both the statistical significance and the systematic reliability of our study. We provide state-of-the-art determinations of key nuclear physics and Standard Model parameters, including the neutron root-mean-square (rms) radius of germanium nuclei, the weak mixing angle, and the neutrino charge radius. The observed tension of about $2 σ$ between the COHERENT germanium measurement and the Standard Model prediction motivates a detailed reassessment of the theoretical cross-section. In particular, we examine the impact of nuclear form factors and uncertainties in the nuclear radius, as well as the potential influence of a systematic shift in the neutrino flux normalisation at the SNS. Our results highlight the reliability of CE$ν$NS as a precision tool, reinforced by the complementarity of different experimental inputs, and lay the groundwork for future advances in the field.

hep-ph↗

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det↗

Reactor antineutrinos CE$ν$NS on germanium: CONUS+ and TEXONO as a new gateway to SM and BSM physics

Coherent elastic neutrino-nucleus scattering (CE$ν$NS) is a key process for probing Standard Model and beyond the Standard Model (BSM) properties. Following its first detection by the COHERENT Collaboration, recent reactor-based experiments provide a unique opportunity to refine our current understanding. In particular, the high-precision data from CONUS+, combined with the strong bounds from TEXONO, not only validate the CE$ν$NS process at low energies but also provide improved constraints on the weak mixing angle, neutrino electromagnetic properties (including the charge radius, millicharge, and magnetic moment), and nonstandard interactions and light mediators. We also examine the role of elastic neutrino-electron scattering, which gains significance in certain BSM scenarios and allows us to obtain the best limit for the millicharge of the electron neutrinos. By combining reactor and higher-energy spallation neutron source measurements, this work strengthens CE$ν$NS as a precision tool for testing the Standard Model and beyond.

hep-ph↗

Production, Quality Assurance and Quality Control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m^2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the quality assurance and quality control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision flip-chip bonding, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

physics.ins-det↗

Fundamental Nuclear and Particle Physics At Neutron Sources

Fundamental neutron and neutrino physics at neutron sources, combining precision measurements and theory, can probe new physics at energy scales well beyond the highest energies probed by the LHC and possible future high energy collider facilities. The European Spallation Source (ESS) will in the not too far future be a most powerful pulsed neutron source and simultaneously the world's brightest pulsed neutrino source. The ESS, and neutron sources in general, can provide unprecedented and unique opportunities to contribute to the search for the missing elements in the Standard Model of particle physics. Currently there are no strong indications where hints of the origin of the new physics will emerge. A multi-pronged approach will provide the fastest path to fill the gaps in our knowledge and neutron sources have a pivotal role to play. To survey the ongoing and proposed physics experiments at neutron sources and assess their potential impact, a workshop was held at Lund University in January, 2025. This report is a summary of that workshop and has been prepared as input to the European Strategy Update.

nucl-ex↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (~40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of $^{83\text{m}}$Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

physics.ins-det↗