SearcharxivSearch

arXiv · 2503.08468

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

Abstract

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (~40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of $^{83\text{m}}$Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

Explore related subjects

Keep this discovery

BibTeXRIS

20k Collaboration, F. Acerbi, P. Adhikari, P. Agnes, I. Ahmad, S. Albergo, I. F. Albuquerque, T. Alexander, A. K. Alton, P. Amaudruz, M. Angiolilli, E. Aprile, M. Atzori Corona, D. J. Auty, M. Ave, I. C. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, A. Barrado Olmedo, P. Barrillon, G. Batignani, P. Bhowmick, M. Bloem, S. Blua, V. Bocci, W. Bonivento, B. Bottino, M. G. Boulay, A. Buchowicz, S. Bussino, J. Busto, M. Cadeddu, M. Cadoni, R. Calabrese, V. Camillo, A. Caminata, N. Canci, M. Caravati, M. Cárdenas-Montes, N. Cargioli, M. Carlini, A. Castellani, P. Castello, P. Cavalcante, S. Cebrian, S. Chashin, A. Chepurnov, S. Choudhary, L. Cifarelli, B. Cleveland, Y. Coadou, V. Cocco, D. Colaiuda, E. Conde Vilda, L. Consiglio, J. Corbett, B. S. Costa, M. Czubak, M. D'Aniello, S. D'Auria, M. D. Da Rocha Rolo, A. Dainty, G. Darbo, S. Davini, R. de Asmundis, S. De Cecco, G. Dellacasa, A. V. Derbin, A. Devoto, F. Di Capua, L. Di Noto, P. Di Stefano, L. K. Dias, D. Díaz Mairena, C. Dionisi, G. Dolganov, F. Dordei, V. Dronik, F. Dylon, A. Elersich, E. Ellingwood, T. Erjavec, N. Fearon, M. Fernandez Diaz, A. Ficorella, G. Fiorillo, P. Franchini, D. Franco, H. Frandini Gatti, E. Frolov, F. Gabriele, D. Gahan, C. Galbiati, G. Galiński, G. Gallina, G. Gallus, M. Garbini, P. Garcia Abia, A. Gawdzik. 2025-03-11. Flow and thermal modelling of the argon volume in the DarkSide-20k TPC. https://doi.org/10.1088/1748-0221%2F20%2F06%2Fp06046

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det