SearcharxivSearch

arXiv subjects

M. Cadeddu

Publications and source records attributed to M. Cadeddu.

At least 19 recordsLinked to original sources

Measurement of the muon flux at SNOLAB using the DEAP-3600 experiment

A direct measurement of the muon flux at SNOLAB is performed using the DEAP-3600 experiment, located 2 km underground at SNOLAB near Sudbury, Canada. Primarily designed for the direct detection of weakly interacting massive particles (WIMPs), a dark matter candidate, DEAP-3600 consists of an inner spherical acrylic vessel containing a liquid argon target; this vessel is enclosed within a steel shell which is submerged in an instrumented water tank, serving as a muon veto for the dark matter search. The muon flux measurement is performed using a cut-and-count analysis of events observed in the muon veto detector and of events which are coincident between the muon veto and the liquid argon target. The requirement that muons traverse both the water and liquid argon minimizes instrumental backgrounds and systematic uncertainties. Using data collected from November 2016 to March 2020, the muon flux is measured by this coincidence analysis to be $(3.71 \pm 0.25_{\textrm{stat}} \pm 0.09_{\textrm{sys}}) \times 10^{-10}\, \mu/$cm$^2$/s. The standalone measurement using muon veto data only is compatible within uncertainties. Both measurements agree with the previous result by the SNO experiment and with simulations carried out using the MUTE software. These results provide an important benchmark for future rare-event searches at the SNOLAB facility.

hep-ex

Testing Lepton Wave Function Factorization in $^{71}\text{Ge}$ Electron Capture

Electron-capture ratios provide precision tests of atomic wave functions and of possible non-factorization effects in nuclear electron capture. By exploiting exact leptonic wave functions, we present a general framework for predicting the electron capture rates of $^{71}\mathrm{Ge}$. Adopting a non-factorized treatment of the transition matrix element, we investigate the interplay between the nuclear transition density, which encodes the nuclear structure contribution, and the leptonic wave functions. Using phenomenologically constrained transition densities, we quantify the impact of non-factorization effects on the capture rates. Finally, we compare our theoretical predictions for the $L/K$, $M/K$ and $M/L$ electron capture ratios with the current experimental world averages, providing an up-to-date assessment of the theoretical and experimental status of $^{71}\mathrm{Ge}$ electron capture.

hep-ph

Search for two-neutrino double electron capture in $^{36}$Ar with the DarkSide-50 detector

Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shells and two neutrinos are emitted. We report on the first search for two-neutrino double electron capture in the $\textit{KK}$- and $\textit{KL}$-shells of $^{36}$Ar using the low-radioactivity liquid argon target from underground sources in the DarkSide-50 experiment. No statistically significant excess was observed with approximately 12 ton-day exposure of underground argon (UAr) and, taking into account the $^{36}$Ar isotopic abundance in UAr (0.007%), we set a limit on the half-life of the two-electron capture process in $^{36}$Ar of $T_{1/2} > 9.2 \times 10^{19}$ yr at 90% C.L. The sensitivity of the DarkSide-20k experiment, which will become operational in the next few years, was also evaluated and is expected to increase by a factor $\sim$100 with 10 years of expected operation and assuming the same $^{36}$Ar abundance as in the DarkSide-50 underground argon target.

nucl-ex

First evidence of neutrino absorption on argon using $^{8}$B solar neutrinos in DEAP-3600

We report experimental evidence for electron neutrino charged-current interactions (neutrino absorption, CC $\nu_e$) from $^{8}$B solar neutrinos on $^{40}$Ar using an exposure of ($7.29 \pm 0.05$) tonne$\cdot$years in the DEAP-3600 detector. A region of interest (ROI) of 10.5-13.0 MeV reconstructed energy calibrated on single-peak events, corresponding to incident neutrino energy in 12.0-14.5 MeV, is used for this measurement. We observe 5 single-peak and 1 double-peak neutrino-like events consistent with the $^{8}$B solar neutrino energy spectrum in the ROI after correcting for nonlinearities in the detector response at high energies. With an expected background of $0.48~^{+0.16}_{-0.15}$ events, the data correspond to a significance of $4.0\,\sigma$ with respect to the background-only hypothesis. We report an energy-averaged cross section of $(4.0~^{+2.0}_{-1.6}~\mathrm{(stat)}~^{+0.8}_{-0.7}~\mathrm{(sys)})\times 10^{-41}\,\mathrm{cm}^2$ in the ROI for the CC $\nu_{e}$ signal, a factor $(2.4~^{+1.3}_{-1.0})$ higher than predicted by Bhattacharya, Goodman and Garc\'ia (2009).

hep-ex

Phenomenological implications of the high-precision COHERENT germanium CE$\nu$NS data

This work presents the first comprehensive phenomenological analysis of the newly released Coherent Elastic Neutrino-Nucleus Scattering (CE$\nu$NS) data on germanium, measured by the COHERENT collaboration at the Spallation Neutron Source. Leveraging the unprecedented precision of this dataset, we provide state-of-the-art determinations of key Standard Model and nuclear physics parameters. Specifically, we extract updated constraints on the weak mixing angle, the neutrino charge radii, and we perform a detailed extraction of the neutron root-mean-square radius of germanium nuclei. We also investigate the impact of quenching factor uncertainties by exploring an extended Lindhard framework, and assess their effect on the extraction of nuclear parameters. Additionally, we use these results to evaluate scenarios beyond the Standard Model, placing robust bounds on neutrino non-standard interactions. To maximize the statistical power and robustness of our findings, whenever possible, we perform a global combined analysis incorporating previous COHERENT measurements along with reactor antineutrino data from the CONUS+, TEXONO, and $\nu$GeN experiments as well as dark-matter experiments.

hep-ph

Dark Matter Search with the DEAP-3600 Detector using the Profile Likelihood Ratio Method

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is based on three parameters: estimated energy, pulse-shape discrimination parameter, and reconstructed position within the detector. Using this method, the expected signal sensitivity of DEAP-3600 benefits from an increased fiducial volume and improved event selection acceptance. Alpha-decays from a small number of dust particulates circulating within the liquid argon target are the dominant source of background events and limit the sensitivity of this search. This result provides improved exclusion upper limits on the WIMP-nucleon spin-independent cross section on liquid argon for WIMP masses between 20 GeV/$c^{2}$ and 100 GeV/$c^{2}$. At 100 GeV/$c^{2}$ the observed limit is 3.4 $\times$ 10$^{-45}$ cm$^2$ at 90% confidence level.

hep-ex

Towards Low-Energy Electron High-Resolution Spectroscopy with Transition-Edge Sensors

We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a critical temperature of $\sim$ 80 mK. The electron source is based on vertically-aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the (92 - 99) eV kinetic energy range, we obtain a Gaussian energy resolution for fully-absorbed electrons of (0.479 $\pm$ 0.041 $\pm$ 0.055) eV. When considering the full-width at half-maximum of the peak, the corresponding resolution is of (1.44 $\pm$ 0.17 $\pm$ 0.27) eV. The former represents an improvement of (46 - 60)% with respect to previous results, and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 20, and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.

physics.ins-det

Characterization of argon recoils at the keV scale with ReD and ReD+

The ReD experiment measured the ionization yield Qy of argon for nuclear recoils in the 2-10 keV range using a dual-phase Time Projection Chamber irradiated with neutrons from a Cf-252 fission source. The measurement extends coverage below 7 keV, confirms consistency with previous data above 7 keV, and indicates a higher Qy at lower energies. These results are relevant for argon-based experiments searching for dark matter in the form of low-mass Weakly Interacting Massive Particles, which are very sensitive to the modeling of the detector response in this energy range.

hep-ex

First Nuclear Ultra-Heavy Dark Matter Search in Argon Time Projection Chambers with the DarkSide-50 Experiment

We report the first search for nuclear ultra-heavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles (WIMPs), nuclear UHDM candidates may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth's overburden, we apply selection criteria optimized for multi-scatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of $m_\chi = 10, 50, 100, 500 \, \mathrm{GeV/c^2}$ are presented.

hep-ex

A possible solution to the gallium anomaly moving beyond the leptonic wave function factorization

For over thirty years, a $\sim20\%$ deficit, now exceeding $5\sigma$, has persisted between measured and predicted neutrino capture rates on $^{71}$Ga, as observed in radioactive source experiments (namely GALLEX, SAGE, and more recently BEST) using $^{51}$Cr and $^{37}$Ar. This long-standing discrepancy, referred to as the gallium anomaly, has posed a significant challenge to our understanding of both experimental methods and theoretical predictions. In this work, we revisit the theoretical calculation of the neutrino capture cross-section by moving beyond the standard treatment of the leptonic wave functions, revealing limitations in the commonly used factorization approach based on the detailed balance principle. Incorporating phenomenologically constrained Gamow-Teller transition densities, able to correctly reproduce the precisely measured half-life of $^{71}{\textrm{Ge}}$, we find that the revised cross-section can be significantly reduced, potentially resolving the gallium anomaly without invoking new physics.

hep-ph

Ultra-high precision high voltage system for PTOLEMY

The PTOLEMY project is prototyping a novel electromagnetic filter for high-precision $\beta$ spectroscopy, with the ultimate and ambitious long-term goal of detecting the cosmic neutrino background through electron capture on tritium bound to graphene. Intermediate small-scale prototypes can achieve competitive sensitivity to the effective neutrino mass, even with reduced energy resolution. To reach an energy resolution better than \SI{500}{meV} at the tritium $\beta$-spectrum endpoint of \SI{18.6}{keV}, and accounting for all uncertainties in the filtering chain, the electrode voltage must be controlled at the level of a few parts per million and monitored in real time. In this work, we present the first results obtained in this effort, using a chain of commercial ultra-high-precision voltage references, read out by precision multimeters and a \emph{field mill} device. The currently available precision on high voltage is, in the conservative case, as low as \SI{0.2}{ppm} per \SI{1}{kV} single board and $\lesssim$ \SI{50}{mV} over the \SI{10}{kV} series, presently limited by field mill read-out noise. However, assuming uncorrelated Gaussian noise extrapolation, the real precision could in principle be as low as \SI{0.05}{ppm} over \SI{20}{kV}.

physics.ins-det

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide programme

Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass WIMP interactions, setting new world-leading constraints in the 1-3 GeV/c^2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.

hep-ex

Characterization of the ionization response of argon to nuclear recoils at the keV scale with the ReD experiment

In the recent years, argon-based experiments looking for Dark Matter in the Universe have explored the non-standard scenario in which Dark Matter is made by low-mass Weakly Interacting Massive Particles, of mass in the range of 1-10 GeV instead of the canonical hundreds of GeV. Detecting such particles is challenging, as their expected signatures are nuclear recoils with energies below 10 keV, observable solely via ionization. This necessitates a precise understanding of the detector response in this energy regime, which remains incomplete for argon. To address this, the ReD experiment was developed within the framework of the DarkSide-20k Collaboration to produce and characterize few-keV nuclear recoils. A compact dual-phase argon Time Projection Chamber (TPC) was irradiated with neutrons from a Cf252 source, to produce Ar recoils in the energy range of interest via (n,n') elastic scattering. A downstream spectrometer composed of 18 plastic scintillators detected the neutrons scattered off Ar nuclei, enabling recoil energy reconstruction via two-body kinematics. The ionization yield Qy of argon, defined as the number of electrons produced per unit energy deposit, was measured in a model-independent way between 2 and 10 keV. These measurements extend direct experimental coverage well below the previous limit of approximately 7 keV. The results are consistent with existing data above 7 keV, while they indicate a higher Qy at lower energies.

nucl-ex

When backgrounds become signals: neutrino interactions in xenon-based dark matter detectors

Direct detection dark matter experiments have proven to be compelling probes for studying low-energy neutrino interactions with both nuclei and atomic electrons, offering complementary information to accelerator and reactor-based neutrino experiments. Recently, the XENONnT and PandaX-4T collaborations reported the first evidence of coherent elastic neutrino-nucleus scattering from $^8\mathrm{B}$ solar neutrinos. Thanks to their excellent background rejection capabilities and distinctive signal signatures, dual-phase time projection chambers are also sensitive to $pp$ solar neutrinos via their elastic scattering off atomic electrons in the target material. Although this signal is subdominant within the Standard Model, it becomes significantly enhanced in many beyond the Standard Model scenarios, offering a unique opportunity to probe new physics in the low-energy regime. In this work, we analyze the latest electron recoil and nuclear recoil data from XENONnT, PandaX-4T, and LUX-ZEPLIN to probe Standard Model and Beyond the Standard Model physics. While the precision of current neutrino measurements from such detectors remains lower than that achieved by dedicated neutrino experiments, their sensitivity to the tau neutrino component of solar neutrinos helps complete the overall picture, especially when investigating flavor-dependent new physics effects.

hep-ph

Toward precision physics tests with future COHERENT detectors

We present a comprehensive sensitivity study of future CE$\nu$NS detectors, focusing on a cryogenic cesium iodide detector and a tonne-scale liquid argon one, currently being developed by the COHERENT Collaboration. These setups will enable precision measurements of the weak mixing angle at low energies and allow accurate extraction of the neutron nuclear distribution radius. We also demonstrate that next-generation detectors will place constraints on the neutrino charge radius comparable to or better than current global fits. In addition, we explore the sensitivity to non standard neutrino electromagnetic properties, such as magnetic moments and millicharges, as well as new mediators. These findings reinforce the role of CE$\nu$NS experiments in the upcoming precision era, with future detectors playing a key role in advancing our understanding of neutrino interactions and electroweak physics at low energies.

physics.ins-det

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

hep-ex

Reassessing the gallium anomaly using self-consistent electron wave functions

The gallium anomaly, a persistent discrepancy exceeding $4\sigma$ in the $^{71}$Ga neutrino capture rates from $^{51}$Cr and $^{37}$Ar radioactive sources by the GALLEX, SAGE, and recently BEST experiments, has challenged particle physics and nuclear theory for over three decades. We present a new calculation of the neutrino capture cross section, abandoning the conventional leading-order approximation for electronic wave functions by numerically solving the Dirac-Coulomb equation for both bound and continuum electron states. Finally, we reevaluate the gallium anomaly, updating its global significance and presenting the most up-to-date status of its interpretation in terms of sterile neutrinos.

hep-ph

Production, Quality Assurance and Quality Control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m^2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the quality assurance and quality control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision flip-chip bonding, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

physics.ins-det