SearcharxivSearch

arXiv subjects

M. Cordelli

Publications and source records attributed to M. Cordelli.

At least 19 recordsLinked to original sources

An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

physics.ins-det

An induced annealing technique for SiPMs neutron radiation damage

The use of Silicon Photo-Multipliers(SiPMs)has become popular in the design of High Energy Physics experimental apparatus with a growing interest for their application in detector area where a significant amount of non-ionising dose is delivered. For these devices, the main effect caused by the neutron fluence is a linear increase of the leakage current. In this paper, we present a technique that provides a partial recovery of the neutron damage on SiPMs by means of an Electrical Induced Annealing. Tests were performed, at the temperature of 20C, on a sample of three SiPM arrays (2x3) of 6 mm^2 cells with 50 um pixel sizes: two from Hamamatsu and one from SensL. These SiPMs have been exposed to neutrons generated by the Elbe Positron Source facility (Dresden), up to a total fluence of 8x10^11 n1MeV-eq/cm^2. Our techniques allowed to reduced the leakage current of a factor ranging between 15-20 depending on the overbias used and the SiPM vendor. Because, during the process the SiPM current can reach O(100 mA), the sensors need to be operated in a condition that provides thermal dissipation. Indeed, caution must be used when applying this kind of procedures on the SiPMs, because it may damage permanently the device itself.

physics.ins-det

Measurement of the charge asymmetry of electrons from the decays of $W$ bosons produced in $p\bar{p}$ collisions at $\sqrt{s}=1.96$ TeV

At the Fermilab Tevatron proton-antiproton ($p\bar{p}$) collider, high-mass electron-neutrino ($eν$) pairs are produced predominantly in the process $p \bar{p} \rightarrow W(\rightarrow eν) + X$. The asymmetry of the electron and positron yield as a function of their pseudorapidity constrain the slope of the ratio of the $u$- to $d$-quark parton distributions versus the fraction of the proton momentum carried by the quarks. This paper reports on the measurement of the electron-charge asymmetry using the full data set recorded by the Collider Detector at Fermilab in 2001--2011 and corresponding to 9.1~fb$^{-1}$ of integrated luminosity. The measurement significantly improves the precision of the Tevatron constraints on the parton-distribution functions of the proton. Numerical tables of the measurement are provided.

hep-ex

A novel measurement of initial-state gluon radiation in hadron collisions using Drell-Yan events

A study of initial-state gluon radiation (ISR) in hadron collisions is presented using Drell-Yan (DY) events produced in proton-antiproton collisions by the Tevatron collider at a center-of-mass energy of 1.96 TeV. This paper adopts a novel approach which uses the mean value of the Z/$γ^*$ transverse momentum $ $ in DY events as a powerful observable to characterize the effect of ISR. In a data sample corresponding to an integrated luminosity of 9.4 fb$^{-1}$ collected with the CDF Run II detector, $ $ is measured as a function of the Z/$γ^*$ invariant mass. It is found that these two observables have a dependence, $ = -8 + 2.2 \ln m_{DY}^2$ [GeV/c], where $m_{DY}$ is the value of the Z/$γ^*$ mass measured in units of GeV/$c^2$. This linear dependence is observed for the first time in this analysis. It may be exploited to model the effect of ISR and constrain its impact in other processes.

hep-ex

Mu2e calorimeter readout system

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.

physics.ins-det

Search for Higgs-like particles produced in association with bottom quarks in proton-antiproton collisions

We report on a search for a spin-zero non-standard-model particle in proton-antiproton collisions collected by the Collider Detector at Fermilab at a center-of-mass-energy of 1.96 TeV. This particle, the $ϕ$ boson, is expected to decay into a bottom-antibottom quark pair and to be produced in association with at least one bottom quark. The data sample consists of events with three jets identified as initiated by bottom quarks and corresponds to $5.4~\text{fb}^{-1}$ of integrated luminosity. In each event, the invariant mass of the two most energetic jets is studied by looking for deviations from the multijet background, which is modeled using data. No evidence is found for such particle. Exclusion upper limits ranging from 20 to 2 pb are set for the product of production cross sections times branching fraction for hypothetical $ϕ$ boson with mass between 100 and 300 GeV/$c^2$. These are the most stringent constraints to date.

hep-ex

The Mu2e calorimeter: quality assurance of production crystals and SiPMs

The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.

physics.ins-det

Search for standard-model Z and Higgs bosons decaying into a bottom-antibottom quark pair in proton-antiproton collisions at 1.96 TeV

The Collider Detector at Fermilab collected a unique sample of jets originating from bottom-quark fragmentation ($b$-jets) by selecting online proton-antiproton ($p\bar{p}$) collisions with a vertex displaced from the $p\bar{p}$ interaction point, consistent with the decay of a bottom-quark hadron. This data set, collected at a center-of-mass energy of $\sqrt{s}=$1.96 TeV, and corresponding to an integrated luminosity of $5.4~\rm{fb}^{-1}$, is used to measure the $Z$-boson production cross section times branching ratio into $b\bar{b}$. The number of $Z\rightarrow b\bar{b}$ events is determined by fitting the dijet-mass distribution while constraining the dominant $b$-jet background, originating from QCD multijet events, with data. The result, $σ(p\bar{p} \rightarrow Z) \times \mathcal{B}(Z \rightarrow b\bar{b})= 1.11\pm 0.08(\text{stat}) \pm 0.14(\text{syst})~\text{nb}$, is the most precise measurement of this process, and is consistent with the standard-model prediction. The data set is also used to search for Higgs-boson production. No significant signal is expected in our data and the first upper limit on the cross section for the inclusive $p\bar p \rightarrow H\rightarrow b\bar b$ process at $\sqrt{s}=$1.96 TeV is set, corresponding to 33 times the expected standard-model cross section, or $σ= 40.6$ pb, at the 95\% confidence level.

hep-ex

Measurement of the differential cross sections for $W$-boson production in association with jets in $p\bar{p}$ collisions at $\sqrt{s}=1.96$ TeV

This paper presents a study of the production of a single $W$ boson in association with one or more jets in proton-antiproton collisions at $\sqrt{s}=1.96$ TeV, using the entire data set collected in 2001-2011 by the Collider Detector at Fermilab at the Tevatron, which corresponds to an integrated luminosity of $9.0$ fb$^{-1}$. The $W$ boson is identified through its leptonic decays into electron and muon. The production cross sections are measured for each leptonic decay mode and combined after testing that the ratio of the $W(\rightarrow μν)+$jets cross section to the $W(\rightarrow eν)+$jets cross section agrees with the hypothesis of $e$-$μ$ lepton universality. The combination of measured cross sections, differential in the inclusive jet multiplicity ($W+\geqslant N$ jets with $N=1,\,2,\,3, \textrm{or }4$) and in the transverse energy of the leading jet, are compared with theoretical predictions.

hep-ex

Design, status and perspective of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.

physics.ins-det

Neutron irradiation test of Hamamatsu, SensL and AdvanSiD UV-extended SiPMs

In this paper, we report the measurement of the neutron radiation hardness of custom Silicon Photomultipliers arrays (SiPMs) manufactured by three companies: Hamamatsu (Japan), AdvanSiD (Italy) and SensL (Ireland). These custom SiPMs consist of a 2 x 3 array of 6 x 6 mm^2 monolithic cells with pixel sizes of respectively 50 um (Hamamatsu and SensL) and 30 um (AdvanSid). A sample from each vendor has been exposed to neutrons generated by the Elbe Positron Source facility (Dresden), up to a total fluence of ~ 8.5 x 10^11 n_(1 MeV)/cm^2. Test results show that the dark current increases almost linearly with the neutron fluence. The room temperature annealing was quantified by measuring the dark current two months after the irradiation test. The dependence of the dark current on the device temperature and on the applied bias have been also evaluated.

physics.ins-det

The Mu2e undoped CsI crystal calorimeter

The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

physics.ins-det

Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment

The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.

physics.ins-det

The Mu2e Calorimeter Final Technical Design Report

Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.

physics.ins-det

Design and status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

physics.ins-det

A search for the exotic meson $X(5568)$ with the Collider Detector at Fermilab

A search for the exotic meson $X(5568)$ decaying into the $B^0_s π^{\pm}$ final state is performed using data corresponding to $9.6 \textrm{fb}^{-1}$ from $p{\bar p}$ collisions at $\sqrt{s} = 1960$ GeV recorded by the Collider Detector at Fermilab. No evidence for this state is found and an upper limit of 6.7\% at the 95\% confidence level is set on the fraction of $B^0_s$ produced through the $X(5568) \rightarrow B^0_s \, π^{\pm}$ process.

hep-ex

Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers

The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to $\sim$8.5~$\times$~10$^{11}$ 1 MeV (Si) eq. n/cm$^{2}$ and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than $\sim$10$^{6}$ hours.

physics.ins-det

Quality Assurance on a custom SiPMs array for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.

physics.ins-det