Searcharxiv⌕ Search

arXiv subjects

M. Ferrario

Publications and source records attributed to M. Ferrario.

At least 37 records · Page 2Linked to original sources

Plasma boosted electron beams for driving Free Electron Lasers

In this paper, we report results of simulations, in the framework of both EuPRAXIA \cite{Walk2017} and EuPRAXIA@SPARC\_LAB \cite{Ferr2017} projects, aimed at delivering a high brightness electron bunch for driving a Free Electron Laser (FEL) by employing a plasma post acceleration scheme. The boosting plasma wave is driven by a tens of \SI{}{\tera\watt} class laser and doubles the energy of an externally injected beam up to \GeV{1}. The injected bunch is simulated starting from a photoinjector, matched to plasma, boosted and finally matched to an undulator, where its ability to produce FEL radiation is verified to yield $O(\num{e11})$ photons per shot at \nm{2.7}.

physics.acc-ph↗

Conceptual design of electron beam diagnostics for high brightness plasma accelerator

A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the proposed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated beams, including emittance, while $μ$m level and fs scale beam size and bunch length respectively are requested. The needed to separate the driver pulse (both laser or beam) from the witness accelerated bunch imposes additional constrains for the diagnostics. We plan to use betatron radiation for the emittance measurement just at the end of the plasma booster, while other single-shot methods must be proven before to be implemented. Longitudinal measurements, being in any case not trivial for the fs level bunch length, seem to have already a wider range of possibilities.

physics.acc-ph↗

Plasma acceleration limitations due to betatron radiation

High energy spread caused by the longitudinal size of the beam is well known in wake-field acceleration. Usually this issue can be solved with beam loading effect that allows to keep accelerating field nearly constant, along the whole duration of the beam. In this work, however, we would like to address another source of energy spread that arises at high energy, due to betatron radiation.

physics.acc-ph↗

Recent studies on single-shot diagnostics for plasma accelerators at SPARC_LAB

Plasma wakefield acceleration is the most promising acceleration technique for compact and cheap accelerators, thanks to the high accelerating gradients achievable. Nevertheless, this approach still suffers of shot-to-shot instabilities, mostly related to experimental parameters fluctuations. Therefore, the use of single shot diagnostics is needed to properly understand the acceleration mechanism. In this work, we present two diagnostics to probe electron beams from laser-plasma interactions, one relying on Electro Optical Sampling (EOS) for laser-solid matter interactions, the other one based on Optical Transition Radiation (OTR) for single shot measurements of the transverse emittance of plasma accelerated electron beams, both developed at the SPARC_LAB Test Facility.

physics.plasm-ph↗

Characterization of self-injected electron beams from LWFA experiments at SPARC_LAB

The plasma-based acceleration is an encouraging technique to overcome the limits of the accelerating gradient in the conventional RF acceleration. A plasma accelerator is able to provide accelerating fields up to hundreds of $GeV/m$, paving the way to accelerate particles to several MeV over a short distance (below the millimetre range). Here the characteristics of preliminary electron beams obtained with the self-injection mechanism produced with the FLAME high-power laser at the SPARC_LAB test facility are shown. In detail, with an energy laser on focus of $1.5\ J$ and a pulse temporal length (FWHM) of $40\ fs$, we obtained an electron plasma density due to laser ionization of about $6 \times 10^{18}\ cm^{-3}$, electron energy up to $350\ MeV$ and beam charge in the range $(50 - 100)\ pC$.

physics.acc-ph↗

Overview of Plasma Lens Experiments and Recent Results at SPARC_LAB

Beam injection and extraction from a plasma module is still one of the crucial aspects to solve in order to produce high quality electron beams with a plasma accelerator. Proper matching conditions require to focus the incoming high brightness beam down to few microns size and to capture a high divergent beam at the exit without loss of beam quality. Plasma-based lenses have proven to provide focusing gradients of the order of kT/m with radially symmetric focusing thus promising compact and affordable alternative to permanent magnets in the design of transport lines. In this paper an overview of recent experiments and future perspectives of plasma lenses is reported.

physics.acc-ph↗

The FLAME laser at SPARC_LAB

FLAME is a high power laser system installed at the SPARC_LAB Test Facility in Frascati (Italy). The ultra-intense laser pulses are employed to study the interaction with matter for many purposes: electron acceleration through LWFA, ion and proton generation exploiting the TNSA mechanism, study of new radiation sources and development of new electron diagnostics. In this work, an overview of the FLAME laser system will be given, together with recent experimental results

physics.acc-ph↗

EUPRAXIA@SPARC_LAB: Beam Dynamics studies for the X-band Linac

In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an ultimate high gradient 1 GeV X-band linac together with a plasma acceleration stage to provide accelerating gradients of the GeV/m order. A FEL scheme is foreseen to produce X-ray beams within 3-10 nm range. A 500-TW Laser system is also foreseen for electron and ion production experiments and a Compton backscattering Interaction is planned together with extraction beamlines at intermediate electron beam energy for neutron beams and THz radiation production. The electron beam dynamics studies in the linac are here presented together with the preliminary machine layout.

physics.acc-ph↗

EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF

On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.

physics.acc-ph↗

Ultra-High Brightness Electron Beams from Very-High Field Cryogenic Radio-frequency Photocathode Sources

Recent investigations of RF copper structures operated at cryogenic temperatures performed by a SLAC-UCLA collaboration have shown a dramatic increase in the maximum surface electric field, to 500 MV/m. We examine use of these fields to enable very high field cryogenic photoinjectors that can attain over an order of magnitude increase in peak electron beam brightness. We present beam dynamics studies relevant to X-ray FEL injectors, using start-to-end simulations that show the high brightness and low emittance of this source enables operation of a compact FEL reaching a photon energy of 80 keV. The preservation of beam brightness in compression, exploiting micro-bunching techniques is discussed. While the gain in brightness at high field is due to increase of the emission current density, further increases in brightness due to lowering of the intrinsic cathode emittance in cryogenic operation are also enabled. While the original proposal for this type of cryogenic, ultra-high field photoinjector has emphasized S-band designs, there are numerous potential advantages that may be conferred by operation in C-band. We examine issues related to experimental implementation in C-band, and expected performance of this type of device in a future hard X-ray FEL such as MaRIE.

physics.acc-ph↗

Recent results at SPARC_LAB

The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show results related to the usability of plasmas as focusing lenses in view of a complete plasma-based focusing and accelerating system.

physics.acc-ph↗

RF injector design studies for the trailing witness bunch for a plasma-based user facility

The interest in plasma-based accelerators as drivers of user facilities is growing worldwide thanks to its compactness and reduced costs. In this context the EuPRAXIA collaboration is preparing a conceptual design report for a multi-GeV plasma-based accelerator with outstanding electron beam quality to pilot, among several applications, the operation of an X-ray FEL, the most demanding in terms of beam brightness. Intense beam dynamics studies have been performed to provide a reliable working point for the RF injector to generate a high-brightness trailing witness bunch suitable in external injection schemes, both in particle beam and laser driven plasma wakefield acceleration. A case of interest is the generation of a witness beam with 1 GeV energy, less than 1 mm-mrad slice emittance and 30 pC in 10 fs FWHM bunch length, which turns into 3 kA peak current at the undulator entrance. The witness beam has been successfully compressed down to 10 fs in a conventional SPARC-like photo-injector and boosted up to 500 MeV in an advanced high-gradient X-band linac reaching the plasma entrance with 3 kA peak current and the following RMS values: 0.06% energy spread, 0.5 mm-mrad transverse normalised emittance and a focal spot down to 1 $μm$. RF injector studies are here presented with the aim to satisfy the EuPRAXIA requests for the Design Study of a plasma-based user facility.

physics.acc-ph↗

Wake fields effects in dielectric capillary

Plasma wake-field acceleration experiments are performed at the SPARC LAB test facility by using a gas-filled capillary plasma source composed of a dielectric capillary. The electron can reach GeV energy in a few centimeters, with an accelerating gradient orders of magnitude larger than provided by conventional techniques. In this acceleration scheme, wake fields produced by passing electron beams through dielectric structures can determine a strong beam instability that represents an important hurdle towards the capability to focus high-current electron beams in the transverse plane. For these reasons, the estimation of the transverse wakefield amplitudes assumes a fundamental role in the implementation of the plasma wake-field acceleration. In this work, it presented a study to investigate which parameters affect the wake-field formation inside a cylindrical dielectric structure, both the capillary dimensions and the beam parameters, and it is introduced a quantitative evaluation of the longitudinal and transverse electric fields.

physics.acc-ph↗

Nano-machining, surface analysis and emittance measurements of a copper photocathode at SPARC_LAB

R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test facility to fully characterize each stage of the photocathode "life" and to have a complete overview of the photoemission properties in high brightness photo-injectors. The nano(n)-machining process presented here consists in diamond milling, and blowing with dry nitrogen. This procedure reduces the roughness of the cathode surface and prevents surface contamination introduced by other techniques, such as polishing with diamond paste or the machining with oil. Both high roughness and surface contamination cause an increase of intrinsic emittance and consequently a reduction of the overall electron beam brightness. To quantify these effects, we have characterized the photocathode surface in terms of roughness measurement, and morphology and chemical composition analysis by means of Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), and Atomic Force Microscopy (AFM) techniques. The effects of n-machining on the electron beam quality have been also investigated through emittance measurements before and after the surface processing technique. Finally, we present preliminary emittance studies of yttrium thin film on Cu photocathodes.

physics.acc-ph↗

Preliminary RF design of an X-band linac for the EuPRAXIA@SPARC_LAB project

In the framework of the upgrade of the SPARC_LAB facility at INFN-LNF, named EuPRAXIA@SPARC_LAB, a high gradient linac is foreseen. One of the most suitable options is to realize it in X-band. A preliminary design study of both accelerating structures and power distribution system has been performed. It is based on 0.5 m long travelling wave (TW) accelerating structures operating in the 2π/3 mode and fed by klystrons and pulse compressor systems. The main parameters of the structures and linac are presented with the basic RF linac layout.

physics.acc-ph↗

Injection, Extraction and Matching

In this lecture we introduce from basic principles the main concepts of beam focusing and transport in modern accelerators using the beam envelope equationas a convenient mathematical tool. Matching conditions suitable for preserving beam quality are derived from the model for significant beam dynamics regimes. An extension of the model to the case of plasma accelerators is introduced. The understanding of similarities and differences with respect to traditionalaccelerators is also emphasized.

physics.acc-ph↗

Space Charge Effects

The space charge forces are those generated directly by the charge distribution, with the inclusion of the image charges and currents due to the interaction of the beam with a perfectly conducting smooth pipe. Space charge forces are responsible for several unwanted phenomena related to beam dynamics, such as energy loss, shift of the synchronous phase and frequency, shift of the betatron frequencies, and instabilities. We will discuss in this lecture the main feature of space charge effects in high-energy storage rings as well as in low-energy linacs and transport lines.

physics.acc-ph↗

Wakefields and Instabilities in Linear Accelerators

When a charged particle travels across the vacuum chamber of an accelerator, it induces electromagnetic fields, which are left mainly behind the generating particle. These electromagnetic fields act back on the beam and influence its motion. Such an interaction of the beam with its surro undings results in beam energy losses, alters the shape of the bunches, and shifts the betatron and synchrotron frequencies. At high beam current the fields can even lead to instabilities, thus limiting the performance of the accelerator in terms of beam quality and current intensity. We discuss in this lecture the general features of the electromagnetic fields, introducing the concepts of wakefields and giving a few simple examples in cylindrical geometry. We then show the effect of the wakefields on the dynamics of a beam in a linac, dealing in particular with the beam breakup instability and how to cure it.

physics.acc-ph↗