SearcharxivSearch

arXiv subjects

M. Garattini

Publications and source records attributed to M. Garattini.

13 recordsLinked to original sources

Search for a new 17 MeV resonance via $e^+e^-$ annihilation with the PADME Experiment

The PADME Experiment at the Frascati DA$\Phi$NE LINAC has searched for a hypothetical particle with mass around 17 MeV, commonly referred to as the X17, using a positron beam incident on a fixed target. The beam energy was varied between 262 and 296 MeV, corresponding to center-of-mass energies $\sqrt{s}$ between 16.4 and 17.4 MeV. The X17 should be produced resonantly via $e^+e^-$ annihilation when $\sqrt{s}$ approaches its mass, inducing an excess of events with a two-body final state over the background expectation. The beam energy spacing was fixed to less than half the expected width of the resonance's line shape. Uncertainties below 1% per $\sqrt{s}$ point were achieved. A blind analysis has been performed. The data are consistent with the expected background in most of the explored energy range, and limits are set in previously unexplored regions of the available parameter space. The most significant deviation is found for $\sqrt{s} \approx 16.90$ MeV, corresponding to a global significance of approximately 2 standard deviations over the null hypothesis expectation.

hep-ex

Steering of Sub-GeV positrons by ultra-thin bent Silicon crystal for ultra slow extraction applications

For the first time at the Beam Test Facility of the DA{\Phi}NE accelerator complex at the Laboratori Nazionali di Frascati of INFN, 450 MeV positrons have been deflected with high efficiency, using the Planar Channeling process in a bent silicon crystal. The deflection angle obtained is beyond 1 mrad. This interesting result finds several applications for manipulation of this kind of beams, in particular for slow extraction from leptons circular accelerators like DA{\Phi}NE. In this work the experimental apparatus, the measurement procedure and the experimental results are reported.

physics.acc-ph

Characterization of the PADME positron beam for the X17 measurement

This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within $\sim$ 1-2 MeV$/c$, a relative beam energy spread below 0.25\%, and an absolute precision in the intensity of the beam at the level of 2\% percent.

hep-ex

Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector

The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.

hep-ex

Commissioning of the PADME experiment with a positron beam

The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target. This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.

physics.ins-det

The PADME beam line Monte Carlo simulation

The PADME experiment at the DA$Φ$NE Beam-Test Facility (BTF) of the INFN Laboratory of Frascati is designed to search for invisible decays of dark sector particles produced in electron-positron annihilation events with a positron beam and a thin fixed target, by measuring the missing mass of single-photon final states. The presence of backgrounds originating from beam halo particles can significantly reduce the sensitivity of the experiment. To thoroughly understand the origin of the beam background contribution, a detailed Geant4-based Monte Carlo simulation has been developed, containing a full description of the detector together with the beam line and its optical elements. This simulation allows the full interactions of each particle to be described, both during beam line transport and during detection, a possibility which represents an innovative way to obtain reliable background predictions

hep-ex

Multiple scattering of channeled and non-channeled positively charged particles in bent monocrystalline silicon

We present the results of an experimental study of multiple scattering of positively charged high energy particles in bent samples of monocrystalline silicon. This work confirms the recently discovered effect of a strong reduction in the rms multiple scattering angle of particles channeled in the silicon (111) plane. The effect is observed in the plane orthogonal to the bending plane. We show in detail the influence of angular constraints on the magnitude of the effect. Comparison of the multiple scattering process at different energies indicates a violation of the law of inverse proportionality of the rms angle of channeled particles with energy. By increasing the statistics, we have improved the results of multiple scattering measurements for particles moving, but not channeled, in silicon crystals.

physics.acc-ph

Crystal slow extraction of positrons from DAFNE: the SHERPA project

The SHERPA project aim is to develop an efficient technique to extract a positron beam from one of the accelerator rings composing the DAFNE complex at the Frascati National Laboratory of INFN, setting up a new beam line able to deliver positron spills of O(ms) length, excellent beam energy spread and emittance. The most common approach to slowly extract from a ring is to increase betatron oscillations approaching a tune resonance in order to gradually eject particles from the circulating beam. SHERPA proposes a paradigm change using coherent processes in bent crystals to kick out positrons from the ring, a cheaper and less complex alternative. A description of this innovative non-resonant extraction technique is reported in this manuscript, including its performance preliminary estimation.

physics.acc-ph

Double-crystal measurements at the CERN SPS

The UA9 setup, installed in the Super Proton Synchrotron (SPS) at CERN, was exploited for a proof of principle of the double-crystal scenario, proposed to measure the electric and the magnetic moments of short-lived baryons in a high-energy hadron collider, such as the Large Hadron Collider (LHC). Linear and angular actuators were used to position the crystals and establish the required beam configuration. Timepix detectors and high-sensitivity Beam Loss Monitors were exploited to observe the deflected beams. Linear and angular scans allowed exploring the particle interactions with the two crystals and recording their efficiency. The measured values of the beam trajectories, profiles and of the channeling efficiency agree with the results of a Monte-Carlo simulation.

physics.acc-ph

Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets

Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of the scattering angle between data and GEANT4 simulation shows excellent agreement in the core of the distributions leaving some residual disagreement in the tails.

physics.ins-det

Reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals

We present the experimental observation of the reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals. According to our measurements the rms angle of multiple scattering in the plane orthogonal to the plane of the channeling is less than half that for non-channeled particles moving in the same crystal. In the experiment we use focusing bent single crystals. Such crystals have a variable thickness in the direction of beam propagation. This allows us to measure rms angles of scattering as a function of thickness for channeled and non-channeled particles. The behaviour with thickness of non-channeled particles is in agreement with expectations whereas the behaviour of channeled particles has unexpected features. We give a semi-quantitative explanation of the observed effect.

physics.acc-ph

Double-crystal setup measurements at the CERN SPS

In this paper, we discuss an experimental layout for the two-crystals scenario at the Super Proton Synchrotron (SPS) accelerator. The research focuses on a fixed target setup at the circulating machine in a frame of the Physics Beyond Colliders (PBC) project at CERN. The UA9 experiment at the SPS serves as a testbench for the proof of concept, which is planning to be projected onto the Large Hadron Collider (LHC) scale. The presented in the text configuration was used for the quantitative characterization of the deflected particle beam by a pair of bent silicon crystals. For the first time in the double-crystal configuration, a particle deflection efficiency by the second crystal of $0.188 \pm 3 \cdot 10^{-5}$ and $0.179 \pm 0.013$ was measured on the accelerator by means of the Timepix detector and Beam Loss Monitor (BLM) respectively. In this setup, a wide range angular scan allowed a possibility to \textit{in situ} investigate different crystal working regimes (channeling, volume reflection, etc.), and to measure a bent crystal torsion.

physics.acc-ph

Commissioning and operation of the Cherenkov detector for proton Flux Measurement of the UA9 Experiment

The UA9 Experiment at CERN-SPS investigates channeling processes in bent silicon crystals with the aim to manipulate hadron beams. Monitoring and characterization of channeled beams in the high energy accelerators environment ideally requires in-vacuum and radiation hard detectors. For this purpose the Cherenkov detector for proton Flux Measurement (CpFM) was designed and developed. It is based on thin fused silica bars in the beam pipe vacuum which intercept charged particles and generate Cherenkov light. The first version of the CpFM is installed since 2015 in the crystal-assisted collimation setup of the UA9 experiment. In this paper the procedures to make the detector operational and fully integrated in the UA9 setup are described. The most important standard operations of the detector are presented. They have been used to commission and characterize the detector, providing moreover the measurement of the integrated channeled beam profile and several functionality tests as the determination of the crystal bending angle. The calibration has been performed with Lead (Pb) and Xenon (Xe) beams and the results are applied to the flux measurement discussed here in detail.

physics.ins-det