SearcharxivSearch

arXiv subjects

M. Kobayashi

Publications and source records attributed to M. Kobayashi.

At least 19 recordsLinked to original sources

First Measurement of Solar Neutrinos through Elastic Neutrino-Electron Scattering at the keV Scale

We report on the first measurement of low-energy solar neutrinos through elastic neutrino-electron scattering in a dark matter experiment, establishing the lowest energy threshold for any neutrino detection to date. The measurement utilizes data from the first two science runs of XENONnT, corresponding to an exposure of 2.46 t $\cdot$ y, and covers electron recoil energies between 1 keV and 140 keV, providing sensitivity to solar neutrinos with energies down to 17 keV. We reject the background-only hypothesis with a statistical significance of $5.0\sigma$ and measure a solar $pp$ neutrino flux of $(10.2 \pm 2.0) \times 10^{10}$ cm$^{-2}$ s$^{-1}$. The result is larger, but statistically consistent with the previous measurement by Borexino at $1.9\sigma$. Together with recent observations of coherent elastic neutrino-nucleus scattering of $^8$B solar neutrinos in XENONnT and other liquid-xenon time projection chambers, these results demonstrate the growing potential of liquid xenon detectors for neutrino physics down to the keV-scale and represent an important milestone towards a next-generation multipurpose observatory.

hep-ex

Search for Magnetic and Spin-Independent Inelastic Dark Matter with XENONnT

We present a search for Magnetic and Spin-Independent inelastic Dark Matter using 2.1 tonne-years of data from the XENONnT experiment. We consider both single- and double-site event topologies, targeting the unique signature of an initial nuclear recoil followed by a delayed de-excitation photon. To suppress backgrounds, we introduce novel directional and kinematic selections based on the inferred speed and direction of the excited dark matter particle between the scatter and decay sites. We find that the collected data are consistent with background expectations, and report 90% C.L. upper limits for both models across the GeV/c2-TeV/c2 mass range.

hep-ex

Direct Measurement of the $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ Decay Branching Ratios with the XENONnT Experiment

We present precision measurements of $^{212}\mathrm{Pb}$ and $^{214}\mathrm{Pb}$ $\beta$ decay branching ratios using $^{220}\mathrm{Rn}$ and $^{222}\mathrm{Rn}$ calibration data from the XENONnT detector, a dual-phase liquid xenon time projection chamber. Characterizing these isotopes is critical, as they lead to significant low-energy backgrounds in rare-event searches. We report ground-state branching ratios of $(14.75 \pm 0.20(\mathrm{stat}) ^{+0.14}_{-0.40}(\mathrm{sys}))\%$ for $^{212}\mathrm{Pb}$ and $(9.8 \pm 0.3(\mathrm{stat}) ^{+0.8}_{-0.2}(\mathrm{sys}))\%$ for $^{214}\mathrm{Pb}$, providing the most precise direct measurements of these transitions to date. These results contribute to enhancing background modeling for dark matter and neutrino experiments, improving sensitivity to solar neutrinos and physics beyond the Standard Model.

nucl-ex

Probing the Solar $^8$B Neutrino Fog with XENONnT

We report a 3.3 $\sigma$ measurement of coherent elastic neutrino-nucleus scattering from solar $^8$B neutrinos using a 6.77 t$\times$yr exposure from the XENONnT experiment, inferring a solar $^8$B neutrino flux of $(5_{-2}^{+3})\times 10^6\,\mathrm{cm}^{-2}\mathrm{s}^{-1}$, consistent with previous measurements. In the presence of the $^8$B "neutrino fog", we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV/$c^2$ spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at $\sim$ 0.02 GeV/$c$ momentum transfer and constrain physics beyond the Standard Model.

hep-ex

Enhancing Neutrinoless Double-Beta Decay Sensitivity of Liquid-Xenon Time Projection Chamber with Augmented Convolutional Neural Network

Dual-phase time projection chamber (TPC) that employs a multi-ton-scale liquid xenon (LXe) target mass is a pioneering detector technology to search for dark matter. Beyond its advantage in dark matter direct detection efforts, the natural xenon target allows it to search for the neutrinoless double-beta decay ($0\nu\beta\beta$) process, which would violate lepton number conservation and indicate that neutrinos are Majorana particles. However, such $0\nu\beta\beta$ searches have been limited by gamma-ray backgrounds originating from the detector materials. In this work, we designed an augmented convolutional neural network (A-CNN) model to extract additional event-topology information from detector data. Using simulation and calibration data from XENONnT, a leading LXe TPC experiment, our model achieved over 60% background rejection while maintaining 90% signal acceptance. This rejection power improves XENONnT's projected sensitivity of the $^{136}$Xe $0\nu\beta\beta$ search by about 40%. The implementation of A-CNN in the data analysis of future liquid xenon observatories, such as XLZD, will further enhance their sensitivities for $0\nu\beta\beta$ with $^{136}$Xe.

physics.ins-det

First Extraction of the Matter Radius of $^{132}$Sn via Proton Elastic Scattering at 200 MeV/Nucleon

The angular distribution of the differential cross sections for proton elastic scattering from $^{132}$Sn at 196-210 MeV/nucleon was successfully measured over a momentum transfer range of 0.80 to 2.1 fm$^{-1}$. Using a relativistic impulse approximation, the root-mean-square matter radius of $^{132}$Sn was extracted to be $4.758^{+0.023}_{-0.024}$ fm, which was compared with the state-of-the-art ab initio calculations. Combined with the charge radius measured at ISOLDE, there are no theoretical calculations consistent with both matter and charge radii within the experimental errors.

nucl-ex

Observation of a broad $p$-wave resonant state in $^{9}$He

We report on the two-body invariant-mass spectroscopy of $^{9}$He, populated via the 1$p$1$n$ knockout reaction from the two-neutron halo nucleus $^{11}$Li at $\sim$250 MeV/nucleon. A broad $p$-wave resonant state of $^{9}$He was observed at 1.28(1) MeV with a width of 0.82(4) MeV.

nucl-ex

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}\nu\text{NS}$) becomes an irreducible background.

hep-ex

Observation of the Forbush decrease on 2024 May 10, using the ALPAQUITA air-shower array at the 70-1000 GV rigidity range

The Andes Large area PArticle detector for Cosmic ray and Astronomy (ALPACA) is a new air-shower array experiment under construction in the Bolivian Andes, and its prototype ALPAQUITA surface array has been operating since 2023 April. In addition to the traditional $\ge$3-hit or $\ge$4-hit coincidences to trigger recording air-shower events, ALPAQUITA records the counting rates of the $\ge$1-hit and $\ge$2-hit events (Any1 and Any2, respectively). We report a successful detection of a Forbush decrease occurred on 2024 May 10 caused by a passage of an interplanetary shock formed ahead of the Interplanetary Coronal Mass Ejection. The amplitude detected in the Any1 rate is 4.26$\pm$0.33% at the median primary rigidity of 76GV which is consistent with the observations with the worldwide neutron monitor and muon detector networks. Under the assumption of a power-law rigidity spectrum, we renormalized the errors of the observed amplitude ($A_{obs}$) and fitted them as a function of the median primary rigidity ($R_{m}$) of each detector and observational method. The result $A_{obs} = (10.9\% \pm 0.9\%) \times (R_{m}/10\,GV)^{-0.55 \pm 0.07}$ exhibits a hard nature of this event. Our non-detection in the Any2 rate decrease constrains the amplitude with a 2$\sigma$ upper limit to be 0.95% at 960GV. This marginally suggests an existence of a spectral softening between 100GV and 1000GV as also suggested by the Misato underground muon detector at 145GV. Although a strong geomagnetic storm was observed during this period, we conclude it does not impact our results. Our novel technique realizes a unique coverage to study the behavior of the Forbush decreases at the highest rigidity.

astro-ph.HE

Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data

We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level.

hep-ex

Spectral Measurement of the $^{214}$Bi beta-decay to the $^{214}$Po Ground State with XENONnT

We report the measurement of the $^{214}$Bi beta-decay spectrum to the ground state of $^{214}$Po using the XENONnT detector. This decay is classified as first-forbidden non-unique, for which theoretical predictions require detailed nuclear structure modeling. A dedicated identification algorithm isolates a high-purity sample of ground-state beta-decays, explicitly excluding events with associated gamma-rays emission. By comparing the measured spectrum, which covers energies up to 3.27 MeV, with several nuclear models, we find that the prediction based on the conserved vector current (CVC) hypothesis provides the best description of the data. Using this dataset, we additionally derive charge and light yield curves for electronic recoils, extending detector response modeling up to the MeV scale.

nucl-ex

Challenging Spontaneous Quantum Collapse with XENONnT

We report on the search for X-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the X-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Di\'osi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. The original values proposed for the strength and the correlation length of the continuous spontaneous localization model are excluded experimentally for the first time.

hep-ex

A space-resolved visible spectrometer system using compact endoscopic optics for full vertical profile measurement of impurity line emissions in superconducting EAST tokamak

In Experimental Advanced Superconducting Tokamak (EAST tokamak) with tungsten divertors and molybdenum first wall, lithiumization and boronization have been frequently carried out to improve the plasma performance, in particular, in long pulse discharges. A study on impurity behaviors of lithium, boron and tungsten atoms/ions in the edge plasma is then crucially important. For the purpose, a space-resolved visible spectrometer system has been newly developed to observe full vertical profiles over a length of 1.7m of impurity line emissions in wavelength range of 320-800nm. For the full vertical profile measurement compact endoscopic optics is employed with an optical fiber bundle for the system, which can be inserted into a 1.5m long extension tube called 'long nose', because the distance between the diagnostic port and plasma center is considerably long. Therefore, a quartz glass window mounted from the vacuum vessel side is designed to withstand the reverse pressure. A mechanical shutter is also designed to open at a large angle of 235 degree so that the viewing angle of nearby ports is not blocked. Two sets of the fiber bundle, 60-channel linear array and 11*10 channel planar array , with a length of 30m are attached to two sets of Czerny-Turner visible spectrometers for one-dimensional (1D) vertical profile measurement of core plasma and two-dimensional (2D) spectroscopy of divertor plasma, respectively. A complementary metal oxide semiconductor (CMOS) detector with 2048*2048 pixels is used for the visible spectrometers. A preliminary result on the full vertical profile is obtained for BII line emission at 703.19nm in the 1D system

physics.plasm-ph

WIMP Dark Matter Search using a 3.1 Tonne-Year Exposure of the XENONnT Experiment

We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of 3.1 tonne-years. In a blind analysis of nuclear recoil events with energies above $3.8\,\mathrm{keV_{NR}}$, we find no significant excess above background. We set new upper limits on the spin-independent WIMP-nucleon scattering cross section for WIMP masses above $10\,\mathrm{GeV}/c^2$ with a minimum of $1.7\,\times\,10^{-47}\,\mathrm{cm^2}$ at $90\,\%$ confidence level for a WIMP mass of $30\,\mathrm{GeV}/c^2$. We achieve a best median sensitivity of $1.4\,\times\,10^{-47}\,\mathrm{cm^2}$ for a $41\,\mathrm{GeV}/c^2$ WIMP. Compared to the result from the first XENONnT science dataset, we improve our sensitivity by a factor of up to 1.8.

hep-ex

Quantum Coherent Transport of 1D ballistic states in second order topological insulator Bi$_4$Br$_4$

We investigate quantum transport in micrometer-sized single crystals of Bi$_4$Br$_4$, a material predicted to be a second-order topological insulator. 1D topological states with long phase coherence times are revealed via the modulation of quantum interference with magnetic field and gate voltage. In particular, we demonstrate the existence of Aharonov-Bohm interference between 1D ballistic states several micrometers long, that we identify as phase-coherent hinge modes on neighboring step edges at the crystal surface. These Aharonov-Bohm oscillations are made possible by a disordered phase-coherent contact region, the existence of which is confirmed by scanning transmission electron microscopy combined with energy-dispersive X-ray spectroscopy (STEM-EDX) of FIB lamellae. Their coherent nature modulates the transmission of the 1D edge states, leading to weak antilocalization and universal conductance fluctuations with surprisingly large characteristic fields and a strongly anisotropic behavior. These complementary experimental results provide a comprehensive, coherent description of quantum transport in Bi$_4$Br$_4$, and establish the material as a second-order topological insulator with topologically protected 1D ballistic states.

cond-mat.mes-hall

Radon Removal in XENONnT down to the Solar Neutrino Level

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,\mu$Bq/kg, equivalent to about 430 $^\text{222}$Rn atoms per tonne of xenon. This was achieved by active online radon removal via cryogenic distillation after stringent material selection. The achieved $^\text{222}$Rn activity concentration is five times lower than that in other currently operational multi-tonne liquid xenon detectors engaged in dark matter searches. This breakthrough enables the pursuit of various rare event searches that lie beyond the confines of the standard model of particle physics, with world-leading sensitivity. The ultra-low $^\text{222}$Rn levels have diminished the radon-induced background rate in the detector to a point where it is for the first time comparable to the solar neutrino-induced background, which is poised to become the primary irreducible background in liquid xenon-based detectors.

physics.ins-det

Evolution of two-neutrons configuration from 11Li to 13Li

In this work we investigate the two-neutron decay of 13Li and of the excited states of 11Li populated via one-proton removal from 14Be and 12Be, respectively. A phenomenological model is used to describe the decay of 11Li and 13Li. While the first one displays important sequential components, the second one appears dominated by the direct two-neutron decay. A microscopic three-body model is used to extract information on the spatial configuration of the emitted neutrons before the decay and shows that the average distance between the neutrons increases going from 11Li to 13Li.

nucl-ex

Low-Energy Nuclear Recoil Calibration of XENONnT with a $^{88}$YBe Photoneutron Source

Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was $55 \pm 12$ accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23 V/cm between 0.3 (0.7) keV$_{\rm NR}$ and 5.0 keV$_{\rm NR}$. This calibration is crucial for accurately measuring the solar $^8$B neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12 GeV/c$^2$.

physics.ins-det