Searcharxiv⌕ Search

arXiv subjects

M. Kobayashi

Publications and source records attributed to M. Kobayashi.

At least 37 records · Page 2Linked to original sources

The XENONnT Dark Matter Experiment

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.

physics.ins-det↗

XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference

The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years (4.18 t fiducial mass) yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.

physics.data-an↗

Search for Light Dark Matter in Low-Energy Ionization Signals from XENONnT

We report on a blinded search for dark matter with single- and few-electron signals in the first science run of XENONnT relying on a novel detector response framework that is physics-model-dependent. We derive 90\% confidence upper limits for dark matter-electron interactions. Heavy and light mediator cases are considered for the standard halo model and dark matter up-scattered in the Sun. We set stringent new limits on dark matter-electron scattering via a heavy mediator with a mass within 10-20\,MeV/$c^2$ and electron absorption of axion-like particles and dark photons for $m_χ$ below 0.186\,keV/$c^2$.

hep-ex↗

Radon Removal in XENONnT down to the Solar Neutrino Level

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,μ$Bq/kg, equivalent to about 430 $^\text{222}$Rn atoms per tonne of xenon. This was achieved by active online radon removal via cryogenic distillation after stringent material selection. The achieved $^\text{222}$Rn activity concentration is five times lower than that in other currently operational multi-tonne liquid xenon detectors engaged in dark matter searches. This breakthrough enables the pursuit of various rare event searches that lie beyond the confines of the standard model of particle physics, with world-leading sensitivity. The ultra-low $^\text{222}$Rn levels have diminished the radon-induced background rate in the detector to a point where it is for the first time comparable to the solar neutrino-induced background, which is poised to become the primary irreducible background in liquid xenon-based detectors.

physics.ins-det↗

A space-resolved visible spectrometer system using compact endoscopic optics for full vertical profile measurement of impurity line emissions in superconducting EAST tokamak

In Experimental Advanced Superconducting Tokamak (EAST tokamak) with tungsten divertors and molybdenum first wall, lithiumization and boronization have been frequently carried out to improve the plasma performance, in particular, in long pulse discharges. A study on impurity behaviors of lithium, boron and tungsten atoms/ions in the edge plasma is then crucially important. For the purpose, a space-resolved visible spectrometer system has been newly developed to observe full vertical profiles over a length of 1.7m of impurity line emissions in wavelength range of 320-800nm. For the full vertical profile measurement compact endoscopic optics is employed with an optical fiber bundle for the system, which can be inserted into a 1.5m long extension tube called 'long nose', because the distance between the diagnostic port and plasma center is considerably long. Therefore, a quartz glass window mounted from the vacuum vessel side is designed to withstand the reverse pressure. A mechanical shutter is also designed to open at a large angle of 235 degree so that the viewing angle of nearby ports is not blocked. Two sets of the fiber bundle, 60-channel linear array and 11*10 channel planar array , with a length of 30m are attached to two sets of Czerny-Turner visible spectrometers for one-dimensional (1D) vertical profile measurement of core plasma and two-dimensional (2D) spectroscopy of divertor plasma, respectively. A complementary metal oxide semiconductor (CMOS) detector with 2048*2048 pixels is used for the visible spectrometers. A preliminary result on the full vertical profile is obtained for BII line emission at 703.19nm in the 1D system

physics.plasm-ph↗

First Search for Light Dark Matter in the Neutrino Fog with XENONnT

We search for dark matter (DM) with a mass [3,12] $\mathrm{GeV} / c^2$ using an exposure of 3.51 $\mathrm{t} \times \mathrm{y}$ with the XENONnT experiment.We consider spin-independent DM-nucleon interactions mediated by a heavy or light mediator, spin-dependent DM-neutron interactions, momentum-dependent DM scattering, and mirror DM. Using a lowered energy threshold compared to the previous WIMP search, a blind analysis of [0.5, 5.0] $\mathrm{keV}$ nuclear recoil events reveals no significant signal excess over the background. XENONnT excludes spin-independent DM-nucleon cross sections $>2.5 \times 10^{-45} \mathrm{~cm}^2$ at $90 \%$ confidence level for 6 $\mathrm{GeV} / c^2$ DM. In the considered mass range, the DM sensitivity approaches the 'neutrino fog', the limitation where neutrinos produce a signal that is indistinguishable from that of light DM-xenon nucleus scattering.

hep-ex↗

Effective field theory and inelastic dark matter results from XENON1T

In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of interest from [4.9, 40.9]$\,$keV$_{\text{NR}}$ to [4.9, 54.4]$\,$keV$_{\text{NR}}$ to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with the background-only hypothesis, with a small background over-fluctuation observed peaking between 20 and 50$\,$keV$_{\text{NR}}$, resulting in a maximum local discovery significance of 1.7\,$σ$ for the Vector$\otimes$Vector$_{\text{strange}}$ ($VV_s$) ChEFT channel for a dark matter particle of 70$\,$GeV/c$^2$, and $1.8\,σ$ for an iDM particle of 50$\,$GeV/c$^2$ with a mass splitting of 100$\,$keV/c$^2$. For each model, we report 90\,\% confidence level (CL) upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case.

hep-ex↗

Evolution of two-neutrons configuration from 11Li to 13Li

In this work we investigate the two-neutron decay of 13Li and of the excited states of 11Li populated via one-proton removal from 14Be and 12Be, respectively. A phenomenological model is used to describe the decay of 11Li and 13Li. While the first one displays important sequential components, the second one appears dominated by the direct two-neutron decay. A microscopic three-body model is used to extract information on the spatial configuration of the emitted neutrons before the decay and shows that the average distance between the neutrons increases going from 11Li to 13Li.

nucl-ex↗

The neutron veto of the XENONnT experiment: Results with demineralized water

Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV) tags neutrons via their capture on gadolinium or hydrogen, which release $γ$-rays that are subsequently detected as Cherenkov light. In this work, we present the key features and the first results of the XENONnT NV when operated with demineralized water in the initial phase of the experiment. Its efficiency for detecting neutrons is $(82\pm 1)\,\%$, the highest neutron detection efficiency achieved in a water Cherenkov detector. This enables a high efficiency of $(53\pm 3)\,\%$ for the tagging of WIMP-like neutron signals, inside a tagging time window of $250\,\mathrm{μs}$ between TPC and NV, leading to a livetime loss of $1.6\,\%$ during the first science run of XENONnT.

physics.ins-det↗

First Indication of Solar $^8$B Neutrinos via Coherent Elastic Neutrino-Nucleus Scattering with XENONnT

We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time projection chamber with a 5.9 t sensitive liquid xenon target. A blind analysis with an exposure of 3.51 t$\times$yr resulted in 37 observed events above 0.5 keV, with ($26.4^{+1.4}_{-1.3}$) events expected from backgrounds. The background-only hypothesis is rejected with a statistical significance of 2.73 $σ$. The measured $^8$B solar neutrino flux of $(4.7_{-2.3}^{+3.6})\times 10^6 \mathrm{cm}^{-2}\mathrm{s}^{-1}$ is consistent with results from the Sudbury Neutrino Observatory. The measured neutrino flux-weighted CE$ν$NS cross section on Xe of $(1.1^{+0.8}_{-0.5})\times10^{-39} \mathrm{cm}^2$ is consistent with the Standard Model prediction. This is the first direct measurement of nuclear recoils from solar neutrinos with a dark matter detector.

hep-ex↗

The π^+π^- Coulomb interaction study and its use in the data processing

In this work the Coulomb effects (Coulomb correlations) in $π^+π^-$ pairs produced in p + Ni collisions at 24 GeV/$c$, are studied using experimental $π^+π^-$ pair distributions in $Q$, the relative momentum in the pair center of mass system (c.m.s), and its projections $Q_L$ (longitudinal component) and $Q_t$ (transverse component) relative to the pair direction in the laboratory system (l.s.). The $Q$, $Q_L$, and $Q_t$ distributions of the {\sl Coulomb pairs} in the c.m.s. have been simulated assuming they are described by the phase space modified by the known point-like Coulomb correlation function $A_C(Q)$, corrected for small effects due to the nonpoint-like pair production and the strong two-pion interaction. The same distributions of {\sl non-Coulomb pairs} have been simulated according to the phase space, but without $A_C(Q)$. It is shown that the number of {\sl Coulomb pairs} in all $Q_t$ intervals, including the small $Q_t$ (small opening angles $θ$ in the l.s.) is calculated with the theoretical precision better than 2\%. The comparison of the simulated and experimental numbers of {\sl Coulomb pairs} at small $Q_t$ allows us to check and correct the detection efficiency for the pairs with small $θ$ (0.06 mrad and smaller). It is shown that {\sl Coulomb pairs} can be used as a new physical tool to check and correct the quality of the simulated events. The special property of the {\sl Coulomb pairs} is the possibility of checking and correcting the detection efficiency, especially for the pairs with small opening angles.

hep-ph↗

XENONnT Analysis: Signal Reconstruction, Calibration and Event Selection

The XENONnT experiment, located at the INFN Laboratori Nazionali del Gran Sasso, Italy, features a 5.9 tonne liquid xenon time projection chamber surrounded by an instrumented neutron veto, all of which is housed within a muon veto water tank. Due to extensive shielding and advanced purification to mitigate natural radioactivity, an exceptionally low background level of (15.8 $\pm$ 1.3) events/(tonne$\cdot$year$\cdot$keV) in the (1, 30) keV region is reached in the inner part of the TPC. XENONnT is thus sensitive to a wide range of rare phenomena related to Dark Matter and Neutrino interactions, both within and beyond the Standard Model of particle physics, with a focus on the direct detection of Dark Matter in the form of weakly interacting massive particles (WIMPs). From May 2021 to December 2021, XENONnT accumulated data in rare-event search mode with a total exposure of one tonne $\cdot$ year. This paper provides a detailed description of the signal reconstruction methods, event selection procedure, and detector response calibration, as well as an overview of the detector performance in this time frame. This work establishes the foundational framework for the `blind analysis' methodology we are using when reporting XENONnT physics results.

hep-ex↗

Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter

Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates < 30 events/(electron*kg*day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.

hep-ex↗

Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors

This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity field, $^{214}\text{Pb}$ background events can be tagged when they are followed by $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays, or preceded by $^{218}\text{Po}$ decays. This was achieved by evolving a point cloud in the direction of a measured convection velocity field, and searching for $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays or $^{218}\text{Po}$ decays within a volume defined by the point cloud. In XENON1T, this tagging system achieved a $^{214}\text{Pb}$ background reduction of $6.2^{+0.4}_{-0.9}\%$ with an exposure loss of $1.8\pm 0.2 \%$, despite the timescales of convection being smaller than the relevant decay times. We show that the performance can be improved in XENONnT, and that the performance of such a software-tagging approach can be expected to be further improved in a diffusion-limited scenario. Finally, a similar method might be useful to tag the cosmogenic $^{137}\text{Xe}$ background, which is relevant to the search for neutrinoless double-beta decay.

hep-ex↗

Lifting of gap nodes by disorder in ultranodal superconductor candidate FeSe1-xSx

The observation of time-reversal symmetry breaking and large residual density of states in tetragonal FeSe$_{1-x}$S$_x$ suggests a novel type of ultranodal superconducting state with Bogoliubov Fermi surfaces (BFSs). Although such BFSs in centrosymmetric superconductors are expected to be topologically protected, the impurity effect of this exotic superconducting state remains elusive experimentally. Here, we investigate the impact of controlled defects introduced by electron irradiation on the superconducting state of tetragonal FeSe$_{1-x}$S$_x$ ($0.18\le x\le 0.25$). The temperature dependence of magnetic penetration depth is initially consistent with a model with BFSs in the pristine sample. After irradiation, we observe a nonmonotonic evolution of low-energy excitations with impurity concentrations. This nonmonotonic change indicates a transition from nodal to nodeless, culminating in gapless with Andreev bound states, reminiscent of the nodal $s_\pm$ case. This points to the accidental nature of the possible BFSs in tetragonal FeSe$_{1-x}$S$_x$, which are susceptible to disruption by the disorder.

cond-mat.supr-con↗

Mass, spectroscopy and two-neutron decay of $^{16}$Be

The structure and decay of the most neutron-rich beryllium isotope, $^{16}$Be, has been investigated following proton knockout from a high-energy $^{17}$B beam. Two relatively narrow resonances were observed for the first time, with energies of $0.84(3)$ and $2.15(5)$ MeV above the two-neutron decay threshold and widths of $0.32(8)$ and $0.95(15)$ MeV respectively. These were assigned to be the ground ($J^π=0^+$) and first excited ($2^+$) state, with $E_x=1.31(6)$ MeV. The mass excess of $^{16}$Be was thus deduced to be $56.93(13)$ MeV, some $0.5$ MeV more bound than the only previous measurement. Both states were observed to decay by direct two-neutron emission. Calculations incorporating the evolution of the wavefunction during the decay as a genuine three-body process reproduced the principal characteristics of the neutron-neutron energy spectra for both levels, indicating that the ground state exhibits a strong spatially compact dineutron component, while the 2$^+$ level presents a far more diffuse neutron-neutron distribution.

nucl-ex↗

Search for events in XENON1T associated with Gravitational Waves

We perform a blind search for particle signals in the XENON1T dark matter detector that occur close in time to gravitational wave signals in the LIGO and Virgo observatories. No particle signal is observed in the nuclear recoil, electronic recoil, CE$ν$NS, and S2-only channels within $\pm$ 500 seconds of observations of the gravitational wave signals GW170104, GW170729, GW170817, GW170818, and GW170823. We use this null result to constrain mono-energetic neutrinos and Beyond Standard Model particles emitted in the closest coalescence GW170817, a binary neutron star merger. We set new upper limits on the fluence (time-integrated flux) of coincident neutrinos down to 17 keV at 90% confidence level. Furthermore, we constrain the product of coincident fluence and cross section of Beyond Standard Model particles to be less than $10^{-29}$ cm$^2$/cm$^2$ in the [5.5-210] keV energy range at 90% confidence level.

hep-ex↗

Design and performance of the field cage for the XENONnT experiment

The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field shaping rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field shaping ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to ${}^{83m}\mathrm{Kr}$ calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.

hep-ex↗