Searcharxiv⌕ Search

arXiv subjects

M. Kobayashi

Publications and source records attributed to M. Kobayashi.

At least 55 records · Page 3Linked to original sources

First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment

We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid target were reduced to unprecedentedly low levels, giving an electronic recoil background rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ in the region of interest. A blind analysis of nuclear recoil events with energies between $3.3$ keV and $60.5$ keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ for a WIMP mass of $28~\mathrm{GeV}/c^2$ at $90\%$ confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.

hep-ex↗

Detector signal characterization with a Bayesian network in XENONnT

We developed a detector signal characterization model based on a Bayesian network trained on the waveform attributes generated by a dual-phase xenon time projection chamber. By performing inference on the model, we produced a quantitative metric of signal characterization and demonstrate that this metric can be used to determine whether a detector signal is sourced from a scintillation or an ionization process. We describe the method and its performance on electronic-recoil (ER) data taken during the first science run of the XENONnT dark matter experiment. We demonstrate the first use of a Bayesian network in a waveform-based analysis of detector signals. This method resulted in a 3% increase in ER event-selection efficiency with a simultaneously effective rejection of events outside of the region of interest. The findings of this analysis are consistent with the previous analysis from XENONnT, namely a background-only fit of the ER data.

hep-ex↗

Searching for universality of dineutron correlation at the surface of Borromean nuclei

The dineutron correlation is systematically studied in three different Borromean nuclei near the neutron dripline, 11Li, 14Be and 17B, via the (p, pn) knockout reaction measured at the RIBF facility in RIKEN. For the three nuclei, the correlation angle between the valence neutrons is found to be largest in the same range of intrinsic momenta, which can be associated to the nuclear surface. This result reinforces the prediction that the formation of the dineutron is universal in environments with low neutron density, such as the surface of neutron-rich Borromean nuclei.

nucl-ex↗

Cosmogenic background simulations for the DARWIN observatory at different underground locations

Xenon dual-phase time projections chambers (TPCs) have proven to be a successful technology in studying physical phenomena that require low-background conditions. With 40t of liquid xenon (LXe) in the TPC baseline design, DARWIN will have a high sensitivity for the detection of particle dark matter, neutrinoless double beta decay ($0νββ$), and axion-like particles (ALPs). Although cosmic muons are a source of background that cannot be entirely eliminated, they may be greatly diminished by placing the detector deep underground. In this study, we used Monte Carlo simulations to model the cosmogenic background expected for the DARWIN observatory at four underground laboratories: Laboratori Nazionali del Gran Sasso (LNGS), Sanford Underground Research Facility (SURF), Laboratoire Souterrain de Modane (LSM) and SNOLAB. We determine the production rates of unstable xenon isotopes and tritium due to muon-included neutron fluxes and muon-induced spallation. These are expected to represent the dominant contributions to cosmogenic backgrounds and thus the most relevant for site selection.

physics.ins-det↗

Searching for Heavy Dark Matter near the Planck Mass with XENON1T

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This work places strong constraints on spin-independent interactions of dark matter particles with a mass between 1$\times$10$^{12}\,$GeV/c$^2$ and 2$\times$10$^{17}\,$GeV/c$^2$. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross-sections for dark matter particles with masses close to the Planck scale.

hep-ex↗

Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures

Argon with an admixture of CF4 is expected to be a good candidate for the gas mixture to be used for a time projection chamber (TPC) in the future linear collider experiment because of its small transverse diffusion of drift electrons especially under a strong magnetic field. In order to confirm the superiority of this gas mixture over conventional TPC gases we carried out cosmic ray tests using a GEM-based TPC operated mostly in Ar-CF4-isobutane mixtures under 0 - 1 T axial magnetic fields. The measured gas properties such as gas gain and transverse diffusion constant as well as the observed spatial resolution are presented.

physics.ins-det↗

Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source

A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is (68.0$^{+6.3}_{-3.7}$) electrons/keV. The $^{37}$Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at (2.83$\pm$0.02) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $^{37}$Ar can be considered as a regular calibration source for multi-tonne xenon detectors.

physics.ins-det↗

Oxygen on-site Coulomb energy in Pr$_{1.3-x}$La$_{0.7}$Ce$_x$CuO$_{4}$ and Bi$_2$Sr$_2$CaCu$_2$O$_{8+δ}$ and its relation with Heisenberg exchange

We study the electronic structure of electron-doped Pr$_{1.3-x}$La$_{0.7}$Ce$_{x}$CuO$_{4}$ (PLCCO ; $T_{c}$ = 27 K, x = 0.1) and hole-doped Bi$_2$Sr$_2$CaCu$_2$O$_{8+δ}$ (Bi2212 ; $T_{c}$ = 90 K) cuprate superconductors using x-ray absorption spectroscopy (XAS) and resonant photoemission spectroscopy (Res-PES). From Res-PES across the O K-edge and Cu L-edge, we identify the O 2p and Cu 3d partial density of states (PDOS) and their correlation satellites which originate in two-hole Auger final states. Using the Cini-Sawatzky method, analysis of the experimental O 2p PDOS shows an oxygen on-site Coulomb energy for PLCCO to be $U_{p}$ = 3.3$\pm$0.5 eV and for Bi2212, $U_{p}$ = 5.6$\pm$0.5 eV, while the copper on-site Coulomb correlation energy, $U_{d}$ = 6.5$\pm$0.5 eV for Bi2212. The expression for the Heisenberg exchange interaction $J$ in terms of the electronic parameters $U_{d}$, $U_{p}$, charge-transfer energy $Δ$ and Cu-O hopping $t_{pd}$ obtained from a simple Cu$_2$O cluster model is used to carry out an optimization analysis consistent with $J$ known from scattering experiments. The analysis also provides the effective one band on-site Coulomb correlation energy $\tilde{U}$ and the effective hopping $\tilde{t}$. PLCCO and Bi2212 are shown to exhibit very similar values of $\tilde{U}$/$\tilde{t}$ $\sim$9-10, confirming the strongly correlated nature of the singlet ground state in the effective one-band model for both the materials.

cond-mat.str-el↗

Material radiopurity control in the XENONnT experiment

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

physics.ins-det↗

Anisotropic Enhancement of Lower Critical Field in Ultraclean Crystals of Spin-Triplet Superconductor UTe2

The paramagnetic spin-triplet superconductor UTe$_2$ has attracted significant attention because of its exotic superconducting properties including an extremely high upper critical field and possible chiral superconducting states. Recently, ultraclean single crystals of UTe$_2$ have become available, and thus measurements on these crystals are crucial to elucidate the intrinsic superconducting properties. Here, we report the thermodynamic critical field $H_{\rm c}$, the lower critical field $H_{\rm c1}$, and the upper critical field $H_{\rm c2}$ at low fields of these high-quality single crystals. From the comparison of the anisotropies in $H_{\rm c1}$ and $H_{\rm c2}$, we find that the experimental $H_{\rm c1}$ values with the magnetic field along $b$- and $c$-axes are anomalously enhanced, showing unusual low-temperature upturns. We propose an effect of the strong Ising-like ferromagnetic fluctuations on the vortex line energy as the origin of the anisotropic enhancement of $H_{\rm c1}$.

cond-mat.supr-con↗

The Triggerless Data Acquisition System of the XENONnT Experiment

The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at $\times10$ and $\times0.5$ gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within $\mathcal{O}\left(10\text{ s}\right)$ for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed $\sim500$ MB/s during calibration. Livetime during normal operation exceeds $99\%$ and is $\sim90\%$ during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.

physics.ins-det↗

Search for New Physics in Electronic Recoil Data from XENONnT

We report on a blinded analysis of low-energy electronic-recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 tonne liquid xenon target reduced the background in the (1, 30) keV search region to $(15.8 \pm 1.3)$ events/(tonne$\times$year$\times$keV), the lowest ever achieved in a dark matter detector and $\sim$5 times lower than in XENON1T. With an exposure of 1.16 tonne-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

hep-ex↗

An approximate likelihood for nuclear recoil searches with XENON1T data

The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 tonne-year exposure.

hep-ex↗

Double-Weak Decays of $^{124}$Xe and $^{136}$Xe in the XENON1T and XENONnT Experiments

We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a $0.87\;\text{kg}\times\text{yr}$ isotope exposure. The statistical significance of the signal is $7.0\,σ$. We use XENON1T data with $36.16\;\text{kg}\times\text{yr}$ of $^{136}$Xe exposure to search for $0νββ$. We find no evidence of a signal and set a lower limit on the half-life of $T_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to $0νββ$. Assuming a $275\;\text{kg}\times\text{yr}$ $^{136}$Xe exposure, the expected sensitivity is $T_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$, corresponding to an effective Majorana mass range of $\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2$.

hep-ex↗

Evolution of the SrTiO$_3$ surface electronic state as a function of LaAlO$_3$ overlayer thickness

The novel electronic properties emerging at interfaces between transition metal oxides, and in particular the discovery of conductivity in heterostructures composed of LaAlO$_3$ (LAO) and SrTiO$_3$ (STO) band insulators, have generated new challenges and opportunities in condensed matter physics. Although the interface conductivity is stabilized when LAO matches or exceeds a critical thickness of 4 unit cells (u.c.), other phenomena such as a universal metallic state found on the bare surface of STO single crystals and persistent photon-triggered conductivity in otherwise insulating STO-based interfaces raise important questions about the role of the LAO overlayer and the possible relations between vacuum/STO and LAO/STO interfaces. Here, we study how the metallic STO surface state evolves using angle-resolved photoemission spectroscopy (ARPES) in situ prepared samples complemented by resonant inelastic X-ray scattering (RIXS) during the growth of a crystalline LAO overlayer. In all the studied samples, the character of the conduction bands, their carrier densities, the Ti3+ crystal field, and the response to photon irradiation bear strong similarities. Nevertheless, we report here that studied LAO/STO interfaces exhibit an instability toward an apparent 2 x 1 folding of the Fermi surface at and above 4 u.c. thickness threshold, which distinguishes these heterostructures from bare STO and sub-critical-thickness LAO/STO.

cond-mat.mtrl-sci↗

Search for neutrinoless quadruple beta decay of $^{136}$Xe in XMASS-I

A search for the neutrinoless quadruple beta decay of $^{136}$Xe was conducted with the liquid-xenon detector XMASS-I using $\rm 327\; kg \times 800.0 \; days$ of the exposure. The pulse shape discrimination based on the scintillation decay time constant which distinguishes $γ$-rays including the signal and $β$-rays was used to enhance the search sensitivity. No significant signal excess was observed from the energy spectrum fitting with precise background evaluation, and we set a lower limit of the half life of 3.7 $\times$ 10$^{24}$ years at 90$\%$ confidence level. This is the first experimental constraint of the neutrinoless quadruple beta decay of $^{136}$Xe.

nucl-ex↗

A novel technique for the measurement of the avalanche fluctuations of a GEM stack using a gating foil

We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplification. The signal charge width and shape (skewness) for electron-ion pairs created by a pulsed UV laser as a function of the transmission rate of the gating foil can be used to determine the relative variance of gas gain for single electrons. We present the measurement principle and the result obtained using a stack of gas electron multipliers (GEMs) operated in a gas mixture of Ar-CF$_4$(3%)-isobutane(2%) at atmospheric pressure. Also discussed is the influence of the avalanche fluctuations on the spatial resolution of the ILD-TPC.

physics.ins-det↗

Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.

physics.ins-det↗