Searcharxiv⌕ Search

arXiv subjects

M. Lindner

Publications and source records attributed to M. Lindner.

At least 37 records · Page 2Linked to original sources

1D YIG hole-based magnonic nanocrystal

Magnetic media with artificial periodic modulation-magnonic crystals (MCs) - enable tunable spin-wave dynamics and band structure engineering. Nanoscaling enhances these capabilities, making magnonic nanocrystals promising for both fundamental studies and applications. Here, we report on the design, fabrication, and characterization of one-dimensional YIG MCs with nanoholes ($d \approx $ 150 nm) spaced $a \approx 1 μ$m apart. Micro-focused Brillouin light scattering and propagating spin-wave spectroscopy, supported by TetraX and MuMax$^3$ simulations, reveal spin-wave transmission over 5 $μ$m in the Damon-Eshbach configuration, and the formation of pronounced band gaps with rejection levels up to 26 dB. Detailed analysis of the spin-wave dispersion uncovered complex mode interactions, including two prominent anticrossings at 3.1 and 18.7 rad/$μ$m, between which the spin-wave energy is predominantly carried by the $n$ = 2 mode, enabling efficient transmission. The results advance the development of functional MCs and open pathways toward 2D magnonic nanoarrays and magnonic RF nanodevices.

cond-mat.mes-hall↗

XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference

The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years (4.18 t fiducial mass) yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.

physics.data-an↗

Search for Light Dark Matter in Low-Energy Ionization Signals from XENONnT

We report on a blinded search for dark matter with single- and few-electron signals in the first science run of XENONnT relying on a novel detector response framework that is physics-model-dependent. We derive 90\% confidence upper limits for dark matter-electron interactions. Heavy and light mediator cases are considered for the standard halo model and dark matter up-scattered in the Sun. We set stringent new limits on dark matter-electron scattering via a heavy mediator with a mass within 10-20\,MeV/$c^2$ and electron absorption of axion-like particles and dark photons for $m_χ$ below 0.186\,keV/$c^2$.

hep-ex↗

Radon Removal in XENONnT down to the Solar Neutrino Level

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,μ$Bq/kg, equivalent to about 430 $^\text{222}$Rn atoms per tonne of xenon. This was achieved by active online radon removal via cryogenic distillation after stringent material selection. The achieved $^\text{222}$Rn activity concentration is five times lower than that in other currently operational multi-tonne liquid xenon detectors engaged in dark matter searches. This breakthrough enables the pursuit of various rare event searches that lie beyond the confines of the standard model of particle physics, with world-leading sensitivity. The ultra-low $^\text{222}$Rn levels have diminished the radon-induced background rate in the detector to a point where it is for the first time comparable to the solar neutrino-induced background, which is poised to become the primary irreducible background in liquid xenon-based detectors.

physics.ins-det↗

First Search for Light Dark Matter in the Neutrino Fog with XENONnT

We search for dark matter (DM) with a mass [3,12] $\mathrm{GeV} / c^2$ using an exposure of 3.51 $\mathrm{t} \times \mathrm{y}$ with the XENONnT experiment.We consider spin-independent DM-nucleon interactions mediated by a heavy or light mediator, spin-dependent DM-neutron interactions, momentum-dependent DM scattering, and mirror DM. Using a lowered energy threshold compared to the previous WIMP search, a blind analysis of [0.5, 5.0] $\mathrm{keV}$ nuclear recoil events reveals no significant signal excess over the background. XENONnT excludes spin-independent DM-nucleon cross sections $>2.5 \times 10^{-45} \mathrm{~cm}^2$ at $90 \%$ confidence level for 6 $\mathrm{GeV} / c^2$ DM. In the considered mass range, the DM sensitivity approaches the 'neutrino fog', the limitation where neutrinos produce a signal that is indistinguishable from that of light DM-xenon nucleus scattering.

hep-ex↗

Effective field theory and inelastic dark matter results from XENON1T

In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1\,tonne$\times$year exposure. For these analyses, we extended the region of interest from [4.9, 40.9]$\,$keV$_{\text{NR}}$ to [4.9, 54.4]$\,$keV$_{\text{NR}}$ to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with the background-only hypothesis, with a small background over-fluctuation observed peaking between 20 and 50$\,$keV$_{\text{NR}}$, resulting in a maximum local discovery significance of 1.7\,$σ$ for the Vector$\otimes$Vector$_{\text{strange}}$ ($VV_s$) ChEFT channel for a dark matter particle of 70$\,$GeV/c$^2$, and $1.8\,σ$ for an iDM particle of 50$\,$GeV/c$^2$ with a mass splitting of 100$\,$keV/c$^2$. For each model, we report 90\,\% confidence level (CL) upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case.

hep-ex↗

The CONUS+ experiment

The CONUS+ experiment aims to detect coherent elastic neutrino-nucleus scattering (CEvNS) of reactor antineutrinos on germanium nuclei in the fully coherent regime, continuing on this way the CONUS physics program started at the Brokdorf nuclear power plant, Germany. The CONUS+ setup is installed in the nuclear power plant in Leibstadt, Switzerland, at a distance of 20.7 m from the 3.6 GW thermal power reactor core. The CEvNS signature will be measured with the same four point-contact high-purity germanium (HPGe) detectors produced for the former experiment, however refurbished and with optimized low energy thresholds. To suppress the background in the CONUS+ detectors, the passive and active layers of the original CONUS shield were modified such to fit better to the significantly changed background conditions at the new experimental location. New data acquisition and monitoring systems were developed. A direct network connection between the experiment and the Max-Planck-Institut fur Kernphysik (MPIK) makes it possible to control and monitor data acquisition in real time. The impact of all these modifications is discussed with particular emphasis on the resulting CEvNS signal prediction for the first data collection phase of CONUS+. Prospects of the planned upgrade in a second phase integrating new larger HPGe detectors are also discussed.

hep-ex↗

Final CONUS results on coherent elastic neutrino-nucleus scattering at the Brokdorf reactor

The Conus experiment studies coherent elastic neutrino-nucleus scattering in four 1 kg germanium spectrometers. Low ionization energy thresholds of 210 eV were achieved. The detectors were operated inside an optimized shield at the Brokdorf nuclear power plant which provided a reactor antineutrino flux of up to 2.3$\cdot$10$^{13}$\,cm$^{-2}$s$^{-1}$. In the final phase of data collection at this site, the constraints on the neutrino interaction rate were improved by an order of magnitude as compared to the previous Conus analysis. The new limit of less than 0.34 signal events kg$^{-1}$\,d$^{-1}$ is within a factor 2 of the rate predicted by the standard model. This constraint is discussed in the context of conflicting measurements and results from another reactor neutrino experiment using similar technology.

hep-ex↗

Background characterization of the CONUS+ experimental location

CONUS+ is an experiment aiming at detecting coherent elastic neutrino-nucleus scattering (CE$ν$NS) of reactor antineutrinos on germanium nuclei in the fully coherent regime, continuing the CONUS physics program conducted at the Brokdorf nuclear power plant (KBR), Germany. The CONUS+ experiment is installed in the Leibstadt nuclear power plant (KKL), Switzerland, at a distance of 20.7 m from the 3.6 GW reactor core, where the antineutrino flux is $1.5\cdot 10^{13}$~s$^{-1}$cm$^{-2}$. The CE$ν$NS signature will be measured with four point-contact high-purity low energy threshold germanium (HPGe) detectors. A good understanding of the background is crucial, especially events correlated with the reactor thermal power are troublesome. A large background characterization campaign was conducted during reactor on and off times to find the best location for the CONUS+ setup. On-site measurements revealed a correlated, highly thermalized neutron field with a maximum fluence rate of $(2.3\pm0.1)\cdot 10^{4}$~neutrons~d$^{-1}$cm$^{-2}$ during reactor operation. The $γ$-ray background was studied with a HPGe detector without shield. The muon flux was examined using a liquid scintillator detector measuring (107$\pm$3)~muons~s$^{-1}$m$^{-2}$, which corresponds to an average overburden of 7.4~m of water equivalent. The new background conditions in CONUS+ are compared to the previous CONUS ones, showing a 30 times higher flux of neutrons, but a 26 times lower component of reactor thermal power correlated $γ$-rays over 2.7 MeV. The lower CONUS+ overburden increases the number of muon-induced neutrons by 2.3 times and the flux of cosmogenic neutrons. Finally, all the measured rates are discussed in the context of the CONUS+ background, together with the CONUS+ modifications performed to reduce the impact of the new background conditions at KKL.

physics.ins-det↗

The neutron veto of the XENONnT experiment: Results with demineralized water

Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV) tags neutrons via their capture on gadolinium or hydrogen, which release $γ$-rays that are subsequently detected as Cherenkov light. In this work, we present the key features and the first results of the XENONnT NV when operated with demineralized water in the initial phase of the experiment. Its efficiency for detecting neutrons is $(82\pm 1)\,\%$, the highest neutron detection efficiency achieved in a water Cherenkov detector. This enables a high efficiency of $(53\pm 3)\,\%$ for the tagging of WIMP-like neutron signals, inside a tagging time window of $250\,\mathrm{μs}$ between TPC and NV, leading to a livetime loss of $1.6\,\%$ during the first science run of XENONnT.

physics.ins-det↗

First Indication of Solar $^8$B Neutrinos via Coherent Elastic Neutrino-Nucleus Scattering with XENONnT

We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time projection chamber with a 5.9 t sensitive liquid xenon target. A blind analysis with an exposure of 3.51 t$\times$yr resulted in 37 observed events above 0.5 keV, with ($26.4^{+1.4}_{-1.3}$) events expected from backgrounds. The background-only hypothesis is rejected with a statistical significance of 2.73 $σ$. The measured $^8$B solar neutrino flux of $(4.7_{-2.3}^{+3.6})\times 10^6 \mathrm{cm}^{-2}\mathrm{s}^{-1}$ is consistent with results from the Sudbury Neutrino Observatory. The measured neutrino flux-weighted CE$ν$NS cross section on Xe of $(1.1^{+0.8}_{-0.5})\times10^{-39} \mathrm{cm}^2$ is consistent with the Standard Model prediction. This is the first direct measurement of nuclear recoils from solar neutrinos with a dark matter detector.

hep-ex↗

XENONnT Analysis: Signal Reconstruction, Calibration and Event Selection

The XENONnT experiment, located at the INFN Laboratori Nazionali del Gran Sasso, Italy, features a 5.9 tonne liquid xenon time projection chamber surrounded by an instrumented neutron veto, all of which is housed within a muon veto water tank. Due to extensive shielding and advanced purification to mitigate natural radioactivity, an exceptionally low background level of (15.8 $\pm$ 1.3) events/(tonne$\cdot$year$\cdot$keV) in the (1, 30) keV region is reached in the inner part of the TPC. XENONnT is thus sensitive to a wide range of rare phenomena related to Dark Matter and Neutrino interactions, both within and beyond the Standard Model of particle physics, with a focus on the direct detection of Dark Matter in the form of weakly interacting massive particles (WIMPs). From May 2021 to December 2021, XENONnT accumulated data in rare-event search mode with a total exposure of one tonne $\cdot$ year. This paper provides a detailed description of the signal reconstruction methods, event selection procedure, and detector response calibration, as well as an overview of the detector performance in this time frame. This work establishes the foundational framework for the `blind analysis' methodology we are using when reporting XENONnT physics results.

hep-ex↗

Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter

Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates < 30 events/(electron*kg*day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.

hep-ex↗

Offline tagging of radon-induced backgrounds in XENON1T and applicability to other liquid xenon detectors

This paper details the first application of a software tagging algorithm to reduce radon-induced backgrounds in liquid noble element time projection chambers, such as XENON1T and XENONnT. The convection velocity field in XENON1T was mapped out using $^{222}\text{Rn}$ and $^{218}\text{Po}$ events, and the root-mean-square convection speed was measured to be $0.30 \pm 0.01$ cm/s. Given this velocity field, $^{214}\text{Pb}$ background events can be tagged when they are followed by $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays, or preceded by $^{218}\text{Po}$ decays. This was achieved by evolving a point cloud in the direction of a measured convection velocity field, and searching for $^{214}\text{Bi}$ and $^{214}\text{Po}$ decays or $^{218}\text{Po}$ decays within a volume defined by the point cloud. In XENON1T, this tagging system achieved a $^{214}\text{Pb}$ background reduction of $6.2^{+0.4}_{-0.9}\%$ with an exposure loss of $1.8\pm 0.2 \%$, despite the timescales of convection being smaller than the relevant decay times. We show that the performance can be improved in XENONnT, and that the performance of such a software-tagging approach can be expected to be further improved in a diffusion-limited scenario. Finally, a similar method might be useful to tag the cosmogenic $^{137}\text{Xe}$ background, which is relevant to the search for neutrinoless double-beta decay.

hep-ex↗

Searches for new physics below twice the electron mass with GERDA

A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background has been observed. The resulting exclusion limits deduced with either Bayesian or Frequentist statistics are the most stringent direct constraints in the major part of the 140-1021 keV mass range. As an example, at a mass of 150 keV the dimensionless coupling of dark photons and axion-like particles to electrons has been constrained to $α$'/$α$ < 8.7x10$^{-24}$ and g$_{ae}$ < 3.3x10$^{-12}$ at 90% credible interval (CI), respectively. Additionally, a search for peak-like signals from beyond the Standard Model decays of nucleons and electrons is performed. We find for the inclusive decay of a single neutron in $^{76}$Ge a lower lifetime limit of $τ_n$ > 1.5x10$^{24}$ yr and for a proton $τ_p$ > 1.3x10$^{24}$ yr at 90% CI. For the electron decay e$^-\rightarrowν_eγ$ a lower limit of $τ_e$ > 5.4x10$^{25}$ yr at 90% CI has been determined.

nucl-ex↗

Stereo neutrino spectrum of 235U fission rejects sterile neutrino hypothesis

Anomalies in past neutrino measurements have led to the discovery that these particles have non-zero mass and oscillate between their three flavors when they propagate. In the 2010's, similar anomalies observed in the antineutrino spectra emitted by nuclear reactors have triggered the hypothesis of the existence of a supplementary neutrino state that would be sterile i.e. not interacting via the weak interaction. The STEREO experiment was designed to study this scientific case that would potentially extend the Standard Model of Particle Physics. Here we present a complete study based on our full set of data with significantly improved sensitivity. Installed at the ILL (Institut Laue Langevin) research reactor, STEREO has accurately measured the antineutrino energy spectrum associated to the fission of 235U. This measurement confirms the anomalies whereas, thanks to the segmentation of the STEREO detector and its very short mean distance to the core (10~m), the same data reject the hypothesis of a light sterile neutrino. Such a direct measurement of the antineutrino energy spectrum suggests instead that biases in the nuclear experimental data used for the predictions are at the origin of the anomalies. Our result supports the neutrino content of the Standard Model and establishes a new reference for the 235U antineutrino energy spectrum. We anticipate that this result will allow to progress towards finer tests of the fundamental properties of neutrinos but also to benchmark models and nuclear data of interest for reactor physics and for observations of astrophysical or geo-neutrinos.

hep-ex↗

Pulse shape discrimination for the CONUS experiment in the keV and sub-keV regime

Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are expected to interact homogeneously in the entire detector volume, specific classes of external background radiation preferably deposit their energy close to the semi-active detector surface, in which diffusion processes dominate that subsequently lead to slower rising pulses compared to the ones from the fully active bulk volume. Dedicated studies of their shape are therefore highly beneficial for the understanding and the rejection of these unwanted events. This article reports about the development of a data-driven pulse shape discrimination (PSD) method for the four 1 kg size PPC HPGe detectors of the CONUS experiment in the keV and sub-keV regime down to 210 eV$_{\text{ee}}$. The impact of the electronic noise at such low energies is carefully examined. It is shown that for an acceptance of 90% of the faster signal-like pulses from the bulk volume, approx. 50% of the surface events can be rejected at the energy threshold and that their contribution is fully suppressed above 800 eV$_{\text{ee}}$. Applied to the CONUS background data, such a PSD rejection cut allows to achieve an overall (15-25)% reduction of the total background budget. The new method allows to improve the sensitivity of future CONUS analyses and to refine the corresponding background model in the sub-keV energy region.

physics.ins-det↗

Full background decomposition of the CONUS experiment

The CONUS experiment is searching for coherent elastic neutrino nucleus scattering of reactor anti-neutrinos with four low energy threshold point-contact high-purity germanium spectrometers. An excellent background suppression within the region of interest below 1keV (ionization energy) is absolutely necessary to enable a signal detection. The collected data also make it possible to set limits on various models regarding beyond the standard model physics. These analyses benefit as well from the low background level of ~10d$^{-1}$kg$^{-1}$below 1keV and at higher energies. The low background level is achieved by employing a compact shell-like shield, that was adapted to the most relevant background sources at the shallow depth location of the experiment: environmental gamma-radiation and muon-induced secondaries. Overall, the compact CONUS shield including the active anti-coincidence muon-veto reduces the background by more than four orders of magnitude. The remaining background is described with validated Monte Carlo simulations which include the detector response. It is the first time that a full background decomposition in germanium operated at reactor-site has been achieved. Next to remaining muon-induced background, $^{210}$Pb within the shield and cryostat end caps, cosmogenic activation and air-borne radon are the most relevant background sources. The reactor-correlated background is negligible within the shield. The validated background model together with the parameterization of the noise are used as input to the likelihood analyses of the various physics cases.

physics.ins-det↗