Searcharxiv⌕ Search

arXiv subjects

M. Maino

Publications and source records attributed to M. Maino.

42 records · Page 3Linked to original sources

GeFRO: a New Charge Sensitive Amplifier Design with a Minimal Number of Front-end Components

A new approach was developed for the design of front-end circuits for semiconductor radiation detectors. The readout scheme consists of a first stage made of only a few components located close to the detector, and of a remote second stage located far from the detector, several meters away. The second stage amplifies the signals from the first stage and closes the feedback loop to discharge the input node after each event. The circuit has two outputs: one gives a "fast" signal, with a bandwidth larger than 20 MHz, allowing to preserve the high frequency components of the detector signals, which may be useful for timing measurements, pile-up rejection or pulse shape discrimination. The second output gives a "slow" signal, whose gain depends only on the value of the feedback capacitor, as happens with a classic charge sensitive amplifier, allowing to obtain higher resolution and lower drift. The prototype was named GeFRO for Germanium front-end, and was tested with a BEGe detector from Canberra. The wide bandwidth of the "fast" signal gave a timing resolution of the order of 20 ns. The noise of the circuit at the "slow" output after a 10 us Gaussian shaping was close to 160 electrons RMS with an input capacitance of 26 pF.

physics.ins-det↗

Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals

We report the results of a search for axions from the 14.4 keV M1 transition from Fe-57 in the core of the sun using the axio-electric effect in TeO2 bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a facility used to test bolometers for the CUORE experiment at the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made using a newly developed low energy trigger which was optimized to reduce the detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the flavor-singlet axial vector matrix element. Bounds are given for the interval 0.15 < S < 0.55.

hep-ex↗

Validation of techniques to mitigate copper surface contamination in CUORE

In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit on the number of background counts in the region of interest is 0.02-0.03 counts/keV/kg/y depending on the adopted mitigation technique.

nucl-ex↗

Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay

We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assuming a background rate of 10^-2 cts/(keV kg y), we find that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the neutrinoless double-beta decay half-life of T_1/2(1 sigma) = 1.6 \times 10^26 y and thus a potential to probe the effective Majorana neutrino mass down to 40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will be T_1/2(1.64 sigma) = 9.5 \times 10^25 y. This range is compared with the claim of observation of neutrinoless double-beta decay in 76Ge and the preferred range of the neutrino mass parameter space from oscillation results.

nucl-ex↗

The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments

We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.

physics.ins-det↗

A new approach to the front-end readout of cryogenic ionization detectors

We present a novel approach to the readout of ionization detectors. The solution allows to minimize the number of components and the space occupation close to the detector. This way a minimal impact is added on the radioactive background in those experiments where very low signal rates are expected, such as GERDA and MAJORANA. The circuit consists in a JFET transistor and a remote second stage. The DC feedback path is closed using a diode. Two signal cables are only necessary for biasing and readout.

physics.ins-det↗